FIBERROAD FR-9T4400 10G Managed Chassis 28 Ports Industrial Ethernet Switch Instruction Manual
- June 12, 2024
- FIBERROAD
Table of Contents
FIBERROAD FR-9T4400 10G Managed Chassis 28 Ports Industrial Ethernet
Switch
Product Information
- Product Name: FR-9T4400 10G Managed Chassis Series
- Description: L3 Managed 10/100/1000Based & 10G, 28 ports Industrial Ethernet Switch
Features
- Cache up to 12Mbit for smooth transfer of 4K video
- Support IEEE802.3/802.3u/802.3ab/802.3z/802.3x store and forward mode
- Support large backplane bandwidth, large swap cache, ensure line-speed forwarding for all ports
- Support ERPS ring network protocol of ITU G.8032 standard, self-healing time less than 20ms
- Support STP/RSTP/MSTP protocol of international standard IEEE 802.3D/W/S
Specification
- Ethernet Standards: IEEE802.3, IEEE802.3u, IEEE802.3z, IEEE802.3ab, IEEE802.3x, IEEE802.3az, IEEE802.3ah, IEEE802.1X, IEEE802.1Q
- Packet Buffer: 12Mbits
- Maximum Frame MAC Address: 10K Bytes
- Forward Mode: Store-and-forward and pass-through (full/half duplex mode)
- Switching Performance:
- Delay: < 7s
- Backplane bandwidth: 128Gbps
- Packet forwarding rate : 95.232M
- Transmission Distance:
- SFP Port: Depends on optical module
- RJ45 Port: 100m using standard CAT5/CAT5e cable
- Power Information:
- Working Voltage: DC9-56V
- Overload Protection
- Power Reverse
- Power Consumption
- POE (optional):
- POE Standard
- POE Power
- POE Line Sequence
- Physical Characteristics:
- Material
- Cooling Mode
- Dimensions
- Installation Mode
- Weight
- Environmental Requirements:
- Operating Temperature
- Operating Humidity
Order Information
- FR-9T448F: 1U Rack, Layer 3 Managed Industrial Switch; 410G SFP + 8Gigabit COMBO(TP+SFP) + 16*10/100/1000M Base-TX, DC9-56V Redundant power (AC220V power supply option, FR-9T448FA)
- FR-9T44F8: 1U Rack, Layer 3 Managed Industrial Switch; 410G SFP+8Gigabit COMBO(TP+SFP) +16*100/1000M Base-FX SFP, DC9-56V Redundant power (AC220V power supply optional, FR-9T44FA)
- FR-9T448F/16P: 1U Rack, Layer 3 Managed Industrial Switch, 410G SFP + 8Gigabit COMBO(TP+SFP) + 16*10/100/1000M Base-T802.3AT PoE, DC48-56V Redundant power
Product Usage Instructions
To use the FR-9T4400 10G Managed Chassis Series, follow these instructions:
- Connect the power supply to the switch and make sure it is within the working voltage range (DC9-56V).
- If required, connect the AC220V power supply using the optional FR-9T448FA or FR-9T44FA.
- Connect the Ethernet devices to the appropriate ports on the switch. Use standard CAT5 or CAT5e cables for RJ45 ports.
- If using fiber ports, add SFP modules to the fiber ports as needed.
- If desired, enable Power over Ethernet (PoE) functionality by connecting devices that support PoE to the corresponding RJ45 ports with PoE optional.
- Ensure proper cooling of the switch by following the cooling mode instructions provided in the user manual.
- Place the switch in a suitable location and install it using the recommended installation mode.
- Make sure the operating temperature and humidity requirements are met for optimal performance.
Brief introduction
Industrial grade L3 core layer switch is a layer 3 network management Ethernet Switch independently developed by Fiberroad that is positioned at the convergence layer and core layer applications. It is a large-port and high- specification product in the industrial control field. This product adopts the industry’s leading Technical standards, can provide stable and reliable Ethernet transmission, with high-quality design and reliability. It can provide users with high-efficiency bandwidth and reliable optical fiber network solutions for Ethernet data exchange, convergence and remote optical transmission. The product has the characteristics of no fan, low power consumption, high reliability, good stability, and easy maintenance. Industrial Ethernet Switch adopt mature technology and open network standards, adapt to low temperature and high temperature, strong anti-electromagnetic interference, anti-salt fog, anti-vibration and anti-shake, equipped with redundant dual power supply (AC/DC), which can offer redundant mechanisms for critical applications that need always-on connections. It can also operate either at standard operating temperature range -40 to 75°C. Industrial switches support standard 19” rack mounts with IP40 protection and are perfect choices for harsh environments, such as industrial networking, intelligent transportation systems (ITS) and are also suitable for many military and utility market applications where environmental conditions exceed commercial product specifications.
Features
- Cache up to 12Mbit for smooth transfer of 4K video
- Support IEEE802.3/802.3u/802.3ab/802.3z/802.3x store and forward mode
- Support large backplane bandwidth, large swap cache, ensure line-speed forwarding for all ports
- Support ERPS ring network protocol of ITU G.8032 standard, self-healing time less than 20ms
- Support STP/RSTP/MSTP protocol of international standard IEEE 802.3D/W/S
- Redundant dual power supply DC or AC power supply specifications are optional, anti-reverse connection, overcurrent protection function
- 40 ° C ~ 75 ° C wide temperature design to ensure that the equipment adapts to a variety of harsh on-site environments
- IP40 grade protection, high strength metal case, fanless, low power design
Specification
Ethernet
Standards
| IEEE802.3 IEEE802.3u IEEE802.3z IEEE802.3ab IEEE802.3x IEEE802.3az
IEEE802.3ah IEEE802.1X IEEE802.1Q
---|---
Packet Buffer| 12Mbits
Maximum Frame| 10K Bytes
MAC Address| 16K
Forward Mode| Store-and-forward and pass-through (full/half duplex mode)
Switching Performance| Delay: < 7μs
Backplane bandwidth: 128Gbps Packet forwarding rate: 95.232M
Transmission Distance
SFP Port| Depends on optical module
RJ45 Port Transmission Distance| 100m(using standard CAT5/CAT5e cable)
Power Information
Working Voltage| DC15-56V/AC 100-240V 50-60HZ
Overload Protection| Yes
Power Reverse| Support
Power
Consumption
| Full load<30W
POE (optional)
POE Standard| IEEE 802.3af/at,PSE
POE Power| Single port Maximum 30W
POE Line Sequence| 1/2(+),3/6(-)end-end bridging method
Physical Characteristics
Material| Metallic aluminum alloy
Cooling Mode| Natural cooling, no fan design
Dimensions| 440mm305mm44mm
Installation Mode| 1U Chassis Installation
Weight| 3.5kg
Environmental Requirements
Operating Temperature| -40℃~75℃
Operating Humidity| 5%~90%(no condensation)
Storage Temperature| -40℃~85℃
---|---
Protection
MTBF| 500,000 hours
Warranty| 5 years warranty, lifetime technical support
Certification Standard
EMI| FCC Part 15 B Class A, EN 55022 Class A
EMS
| EN61000-4-2(ESD), EN61000-4-3(RS), EN61000-4-4(EFT), EN61000-4-5(Surge),
EN61000-4-6(CS), EN61000-4-8, EN61000-4-11
Impact| IEC60068-2-27
Drop| IEC60068-2-32
Vibration| IEC60068-2-6
Safety Level| EN60950-1
Layer 2 Function
Redundant Network| Support STP/RSTP,support EAPS、ERPS
Multicast Support| Support IGMP Snooping V1/V2/V3,support GMRP
VLAN| Support IEEE 802.1Q 4K VLAN,support QINQ
Link Aggregation| Support manual aggregation,support static/dynamic LACP
QOS| Support COS、DSCP,8 queues,support WRR、SP、WFQ,QOS
POE Management| Support total power control,POE on/ off,port power sequencing,
POE timing
Diagnostic Maintenance| Support port mirroring, Syslog, Ping
Management Function| Support CLI、WEB、SNMP,Telnet server for management
Alarm Management| Support 1 way relay alarm output, RMON, TRAP
Security
| Support DHCP Snooping,Option 82,802.1X security access, Support user
hierarchical management, ACL access control list, Support DDOS,port-based MAC
filtering / binding, MAC whitelist
Port Management| Support port startup and disabling, support rate setting,
Support 802.3x flow control, port name modification
---|---
Layer 3 function
Static routing function| Routing function IPV4 / IPV6 static routing 1024
(IPv4), 512 (IPv6)
Routing function| RIP OSPF VRRP ARP ND full routing
Login account
Login IP| 192.168.1.6
User Name / Password| Admin/admin
Note: The SFP model does not contain optical modules by default. If you find any shortage or damage, please contact us in time.
Precautions
To avoid damage to the equipment and personal injury caused by improper use, please observe the following precautions:
- Keep the power off during installation, wear an anti static wrist, and ensure that the anti static wrist is in good contact wi th the skin to avoid potential safety hazards.
- The switch can work normally under the correct power supply. Please confirm that the power supply voltage matches the voltage indicated by the switch.
- Before powering on the switch, please make sure that the power circuit is not overloaded, so as not to affect the normal operation of the switch and even cause unnecessary damage.
- To avoid the risk of electric shock, do not open the case while the switch is working, even if it is not charged, do not op en it yourself.
- Before cleaning the switch, pull out the power plug of the switch. Do not wipe with a wet cloth. Do not use liquid to clean it
- The equipment installed in the rack is generally from bottom to top to avoid overload installation.
- Avoid placing other heavy objects on the surface of the switch to avoid accidents.
Order Information
FR-9T448F| 1U Rack, Layer 3 Managed Industrial Switch;410G SFP + 8Gigabit COMBO(TP+SFP)
*+ 1610/100/1000M Base-TX, DC9-56V Redundant power (AC220V power supply option, FR-9T448FA)**
---|---
FR-9T44F8| 1U Rack, Layer 3 Managed Industrial Switch;410G SFP+8Gigabit
COMBO(TP+SFP)
+16*100/1000M Base-FX SFP, DC9-56V Redundant power (AC220V power supply optional, FR-9T44FA)
FR-9T448F/16P| 1U Rack, Layer 3 Managed Industrial Switch, 410G SFP + 8Gigabit COMBO(TP+SFP)
*+ 1610/100/1000M Base-T 802.3AT PoE, DC48-56V Redundant power**
Fiber port can add SFP module. RJ45 port with PoE optional. Fiberroad Technology Co., Limited www.fiberroad.com.cn.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>