eyc-tech THE120 Relative Humidity Sensor User Manual

June 12, 2024
eyc-tech

eyc-tech THE120 Relative Humidity Sensor User Manual
Relative Humidity Sensor

Security considerations

Please read this Specification carefully, prior to use of this, and keep the manual properly, for timely reference.
Solemn Statement :
This product cannot be used for any explosion-proof area.
Do not use this product in a situation where human life may be affected.
eYc-tech will not bear any responsibility for the results produced by the operators !

Warning!

  • Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards.
  • This product must be operated under the operating conditions specified in manual to prevent equipment damages.
  • Please using the product under the ordinary pressure, or it will influence safe problem.
  • This product must be operated under the operating condition specified in this manual to prevent equipment damages.
  • This product must be operated under the normally atmospheric condition to prevent equipment damages.
  • To prevent products damage, always disconnect the power supply from the product before performing any wiring and installation.
  • All wiring must comply with local codes of indoor wiring and electrical installation rules.
  • Please use crimp type terminal.
  • To prevent personal injury, do not touch the moving part of product in operation.

It may cause high humidity atmosphere during the product was breakdown. Please take safety strategy.

Connection Diagram
Connection Diagram
RS-485 and Modbus
THE120 integrate a RS-485 interface for digital communication as an option feature. Based on Modbus protocol makes the general convenience on PLC, HMI and PC connection. For Modbus protocol information please download the file from website. Besides the PLC, HMI application, the user software provide the device setting and data logging function, it also can free download from website.

Technical Data:

  1. Max. Network size: 32 transmitters
  2. Communication: with COM-Port (serial interface) of PC
  3. Max. Network expansion: 1200m (3937ft) total length at 9600 baud
  4. Transmission rate: 9600, 19200, 38400, 57600, 115200 Baud
  5. Parity: None, Even, Odd
  6. Data length: 8 bit
  7. Stop bit: 1 or 2 bit
  8. Factory default Station address = 1, Data format= 9600, N81

Software and calibration operation step

  1. Portable application:eYc-THE120-UI-20211020-1.0.0 (EXE)

  2. Installation program: eYc-THE120-U1-20211020-1.0.0 (INSTALLER).rar
    (3% Please contact us to download installation program when free program doesn’t execute. )
    a. Operating System requirements: above Windows XP SP2
    b. Decompress installation program and click Setup to install
    oftware and calibration operation step
    c. Navigate to program and click THE120
    Navigate to program a

  3. Hardware connection: Connect the THE120 to PC through USB to RS-485 converter

  4. Check the COM port number from Device Manager in Computer Management. e.g.
    COML1 inillustration
    COML1 inillustration

  5. Open the THE120 Ul

  6.  Goto function Interface

  7. Click Config
    Config

  8. Connection method – If known station number ID:

  9. Setting COM PORT

  10. Setting BAUD RATE

  11. Setting DATA FRAME

  12. Setting Station ID

  13. Click Apply for connection
    Connection method

  14. Connection Method-If unknown station number ID ( Scan R485):

  15. Setting COM PORT, click Scan for scan devices

  16. Choose the device and click Close and Export

  17. Click Apply for connection
    Connection Method

  18. Setting on analog output
    In Output tab, OUT1/OUT2 group, the output related setting could be found:

  19. Quantity : Temperature, Relative Humidity

  20. Response rate (0 … 100) 100 : Filter OFF » 90 : Filter =60 sec. » 80 : Filter =120 sec., etc.

  21. Analogtype: 4…20 mA (Current) /0… 10V (Voltage)\

  22. Measuring range: Upper and Lower
    Setting on analog output

  23. Setting Environment, Modbus Protocol
    There are 2 groups in setting tab. The description of each item as below.
    Environment :

  24. Air Pressure (mBar)
    Modbus Protocol :
    Environment

  25. Station ID

  26. Baud Rate

  27. Data Frame

  28. Modbus Echo Test Enable / Disable

  29. Modbus Echo Test Result Reset

  30. Data display and logging
    Data display and logging
    Data display and logging

  31. Device Information
    Device Information

  32. Serial number

  33. Model name

  34. Firmware version

  35. RS-485

  36. Temperature range(°C)

  37. Calibration date

  38. Firmware checksum

  39. Hardware version

  40. Humidity calibration data

  41. Temperature calibration data

  42. Analog output calibration data

  43. Analog output programming span

Inspection and maintenance

  1. Maintenance
    Since this product is inspected and calibrated for high accuracy at the factory
    before shipment, no calibration on the installation site is necessary when this product is
    installed. For inspection and maintenance follow the instructions below :

    • Periodic inspection Periodically inspect this product for its sensing accuracy, and clean the cover. Set the period between inspections based on atmospheric dust and other contaminants in the installation environment.
  2. Troubleshooting

    • Sensor maintenance
      Do not damage sensor surface during the maintenance process.

    • Troubleshooting
      If any problem occurs during operation, refer to the table below for appropriate solutions.

Problem Clack items Soluations
  • No output
  • Unstable output

|

  • Disconnected wiring
  • Loose wiring
  • Power supply voltage
  • Sensor damages

|

  • Re-perform wiring

  • Crew on terminal tightly or replace wires

  • Replace the sensor

  • Slow response to output

  • Errow in output

|

  • Moisture condensation onthe product
  • Check installed location
  • Check installed angle
  • Check dust and contamination on the sensor

|

  • Remove the sensor and filter. Dry power-off state sensor in clean air seasoning
  • Refer to the section ® Align measurement head with flow direction
  • Cleaning the filter
  • Changing the filter
  • Calibrate
  • Replace the sensor

ustainable | Professional | Green

Temperature & Humidity / Dew Point / Air Velocity & Volume / Flow
Differential Pressure / Air Quality
Measuring Specialist

Tel : 886-2-8221-2958
Web : www.eyc-tech.com
e-mail : [email protected]
www.eyc-tech.com

Eyc Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

eyc-tech User Manuals

Related Manuals