 ASSEMBLY INSTRUCTION

speakON ® | Loudspeaker Cable Connector

NEU-NL2FXX-W-S

A IMPORTANT SAFETY INFORMATION

!

  • ATTENTION: speak ON® IS NOT TO BE USED AS AN AC/DC MAINS OR POWER SUPPLY CONNECTOR!
  • CAUTION: CONNECTOR NOT TO BE ENGAGED AND DISENGAGED IN NORMAL USED WHEN LIVE OR UNDER LOAD.
  • ATTENTION: NE PAS UTILISER POUR COUPER LE COURANT
  • TO BE INSTALLED BY QUALIFIED PERSON ONLY.

Approval based:  | EN/IEC
EN 61984
IEC 61984| ** UL / CSA
UL 1977
CAN/CSA C22.2 No.182.3
---|---|---
Rating:| 250 V ac / 30 A| 250 V ac / 30 A
Wire size:| 1.0 – 4.0 mm²| 16 – 11 AWG
Cable O.D.:*   -S:| 6.0 – 12.0 mm (0.24 – 0.47″)| 6.0 – 12.0 mm (0.24 – 0.47″)

*-L:

| 10.0 – 16.0 mm (0.39 – 0.63″) | 10.0 – 16.0 mm (0.39 – 0.63″)

B ASSEMBLY INFORMATION

(A) Place the bushing (1) and chuck (2) over the cable.

Important: Chuck and Bushing cannot be placed overthe cable afterthe assembly orthe insert.

(B) Prepare the cable as shown.

(B) CABLE PREPARATION: 2 POLE

CABLE PREPARATION: 4 POLE

(C) Slide the cable into the contacts and clamp

(C)

  1. Torx size T8
  2. Torque Value 0.7 Nm (6.2 inch pound)

WIRING: 2 POLE  WIRING: 4 POLE

(D)

Neutrik Group NL2FXX-W SpeakON Loudspeaker Cable Connector
6

a: Important: Push and turn simultaneously.
b: Important: Align the chuck by positioning the nose into keyway.
c: Important: All 3 parts must habe the SAME COLOR CODING, BROWN (2 pole) or GREEN (4 pole).

(D) Position chuck (1) on insert (2).
(E) Slide insert (2) with chuck (1) together into housing (3).
Slide bushing (4) over chuck (1).

(E)

Neutrik Group NL2FXX-W SpeakON Loudspeaker Cable Connector
7

a: 27 mm 1 1/8 inch Hex bit
b: Neutrik HTLACA
c: Neutrik HTLACB
d: Torque Value 2.5 Nm (22 inch pound / 1.8 lb-ft)

Hold the connector with the NEUTRIK tool (5) and tighten bushing with the NEUTRIK tool (6) as shown.

For an exact mounting position use a torque wrench with 27 mm (1 1/8 inch) hex bit (7) and tighten it with 2.5 Nm (22 inch pound / 1.8 lb-ft).

NEUTRIK tool Information:
(5) HTLACA
(6) HTLACB

C FINISHED CONNECTOR

NL2FXX-W-                  NL4FXX-W-

D DISASSEMBLY INFORMATION

FOR DISASSEMBLY!

(1) Use the Neutrik tool HTLACB.
(2) Position the tool on the surfaces and open the clamping sleeve.

HTLACB

E SAFETY INFORMATION

CAUTION
To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no freedangling cable windings etc.).

SAFETY WARNING
For safety and certification reasons the connector must be replaced in case of any broken parts or excessive wear and tear.