eyc-tech THM06 Temperature and Humidity Transmitter Instruction Manual
- June 12, 2024
- eyc-tech
Table of Contents
Operation Manual
eYc THMO06 Industrial Accuracy
Temp. & Humidity Transmitter
Security considerations
Please read this Specification carefully, prior to use of this, and keep the
manual properly, for timely reference.
Solemn Statement:
This product can not be used for any explosion-proof area.
Do not use this product in a situation where human life may be affected.
eyc-tech will not bear any responsibility for the results produced by the
operators !
Warning!
- Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards.
- This product must be operated under the operating conditions specified in manual to prevent equipment damages.
- Please using the product under the ordinary pressure, or it will influence safe problem.
- This product must be operated under the operating condition specified in this manual to prevent equipment damages.
- This product must be operated under the normally atmospheric condition to prevent equipment damages.
- To prevent products damage, always disconnect the power supply from the product before performing any wiring and installation.
- Allwiring must comply with local codes of indoor wiring and electrical installation rules.
- Please use crimp type terminal.
- To prevent personal injury, do not touch the moving part of product in operation.
- It may cause high humidity atmosphere during the product was breakdown. Please take safety strategy.
Dimension
Diagram
Software configuration
4.1 Application requirements
Download the configuration software from eYc website, decompress it and
execute it.
The operating system requirements: Windows XP SP2 or above. Hardware
requirements: RS-485 interface, such as a USB to RS-485 or RS-232 to RS-485
converter
4.2 Setting RS-485 connection
- Connect product to PC via RS-485 cable
- Execute THMO6 Ul
- Click “Interface > Config”
- Select the corresponding values of com port as following:
a.Port : Check Come Port
b.Baud Rate
c. Data Frame
d.Timeout
e.Retry
f. Station ID(Default 1)![eyc tech THM06 Temperature and Humidity Transmitter
-
Config 2](https://manuals.plus/wp-content/uploads/2023/08/eyc-tech-THM06 -Temperature-and-Humidity-Transmitter-Config-2.png)
- Click “Apply”
- Connect successfully
a.Show value and trend chart of temperature
b.Show value and trend chart of relative humidity
c.Show “Open Port, Read successful”
4.3 Scan RS-485 connection
Use scan function to connect when forgetting the connection information
or having more facilities
-
Connect the product to PC via RS-485 cable
-
Execute THMO6 Ul
-
Click “Interface > Config”
-
Select the corresponding values of com port as fallowing:
a.Port:
b. RS-485 -
Click “Scan” to execute connection facilities
-
Scan connection facilities and set up
a. Select Station ID
b. Click “CLOSE AND EXPORT” -
Click “Apply”
-
Connect successfully
a.Show value and trend chart of temperature
b.Show value and trend chart of relative humidity
c.Show “Open Port, Read successful”
4.4 Setting RS-485 ModBus Protocol
-
Setting RS-485 connection step as step 4.2 0or 4.3
-
Click “Setting”
-
Select Modbus Protocol parameter
a. Station ID: 1~247
b. Baud Rate: 9600, 19200, 38400, 57600, 115200
c. Data Frame: None-8Bit-1Stop, None-8Bit-2Stop, Even-8Bit-1Stop, Even-8Bit- 2Stop,Odd-8Bit-lStop, Odd-8Bit-lStop -
Click “Apply”
-
Execute connection as step 4.2 or 4.3 again
4.5 Display and save data
-
Show Data : Click ” Display”
-
Icon function statements
| Clear the chart records
---|---
| Change the chart style
| Select the OUTPUT channel
| Set line color chosen from OUTPUT
| Snap chart
| Show/Not show measuring data
| Adjust time range of X axis
| Adjust time range of Y axis
| Save the data measuring when the system start connecting before clinking the Exporticon
| Show/Not show the statement of Y axis
| Show/Not show the statement of X axis
| Show/Not show the statement of Y secondary axis
| Show/ Not show chart -
Setting time interval of record
a. File > Log Interval
b. Select time interval of record -
Save/Log measuring data
a. Log measuring range : Save the data measuring when the system start connecting
before clinking the Export icon a-1. Click Display > Exporta-2. Appoint path and Key in file name > save
1. If file name is some as the path name, the original file will be over write.b. Log measuring data : Log the data which is on from start or off
b-1. Display > Log(OFF)b-2. Appoint path and Key in file name > save > Log (ON)
1. If file name is some as the path name, the original file will be over write.
4.6 Choose parameter of Output
-
Click “Output”
-
Select relative parameters of Outputl
a. Measures
b. Responding Rate
c. Voltage or current analog range
d. Upper and Lower point of Output -
Click “Apply”
-
Select relative parameters of Output2
a. Measures
b. Responding Rate
c. Voltage or current analog range
d. Upper and Lower point of Output -
Click “Apply”
Display and Keypad operation menu
The THMO06 with display (optional) provides 4-digit display, which adopts alternate display, each measurement value is displayed for 3 seconds, and then another measurement value is alternately displayed. The alternate display can display up to two measurement results. There are two LED sign to indicate the measurement items of the displayed value. When the LED on the left is on, it means the measured value of CH1is displayed, and when the LED on the right is on, it means the measured value of CH2. For example, the THMO6 is now display CH1 reading 180.0 in below figure. The operation flow is as follow.
Inspection and maintenance
-
Maintenance
Since this product is inspected and calibrated for high accuracy at the factory before shipment, no calibration on the installation site is necessary when this product is installed. For inspection and maintenance follow the instructions below:
• Periodic inspection
Periodically inspect this product for its sensing accuracy, and clean the cover. Set the period between inspections based on atmospheric dust and other contaminants in the installation environment. -
Troubleshooting
• Sensor maintenance
Do not damage sensor surface during the maintenance process.
• Troubleshooting
If any problem occurs during operation, refer to the table below for appropriate solutions. Problem| Cleck items| Soluations
---|---|---
• No output
• Unstable output| • Disconnected wiring
• Loose wiring
• Power supply voltage
• Sensor damages| • Re-perform wiring
• Crew on terminal tightly or replace wires
• Replace the sensor
• Slow response to output
• Errow in output| • Moisture /condensation on the product
• Checkinstalled location
• Checkinstalled angle
• Check dust and contaminationon the sensor| • Remove the sensor and filter. Dry power-off state sensor in clean air seasoning
• Refer to the section
• Align measurement head with flow direction
• Cleaning the filter
• Changing the filter
• Calibrate
• Replace the sensor
eyc-tech Measuring Specialist
enhance your capability with sensor technology
Air flow| Humidity| Dew point| Differential pressure| Liquid flowTemp.
| Pressure| Level| Air quality| Signal meter
Tel.: 886-2-8221-2958
Web: www.eyc-tech.com
e-mail:info@eyc-tech.com