GE APPLIANCES P2B935YPFS 30 Inch Dual Fuel Smart Range Instruction Manual

June 12, 2024
GE Appliances

GE-logo

GE APPLIANCES P2B935YPFS 30 Inch Dual Fuel Smart Range

Installation Instructions

Range
Questions? Call GE Appliances at 1.800.GE.CARES (1.800.432.2737) or visit GEAppliances.com. In Canada, call 1.800.561.3344 or visit GEAppliances.ca.

IN THE COMMONWEALTH OF MASSACHUSETTS

  • This product must be installed by a licensed plumber or gas fitter.
  • ” Whey shail be the Mihanaie type.ft valves,
  • A flexible gas connector, when used, must not exceed 5 feet.

WARNING
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Installation must be performed by a qualified installer. Read these instructions completely and carefully. Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/ NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/GA- B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/CGA-1.1 latest edition. When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector. Leak testing of the appliance shall be conducted according to the manufacturer instructions. The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section. Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.

FOR YOUR SAFETY

WARNING
Tip-Over Hazard

  • A child or adult can tip the range and be killed.
  • Install the anti-tip bracket to the wall or floor. Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
  • Re-engage the anti-tip bracket if the range is moved.
  • Failure to do so can result in death or serious burns to children or adults

If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561.3344.) For installation instructions of the bracket, visit: www.GEAppliances.com. (In Canada, www.GEAppliances.ca.)

WARNING
Before beginning the installation, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

TOOLS YOU WILL NEED

GE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-
Range-fig-1 \(3\)

MATERIALS YOU MAY NEED

  • Gas line shut-off valve
  • Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and propane gases
  • Flexible metal appliance connector (1/2″ I.D.). A 5-foot length is recommended for ease of installation but other lengths are acceptable.
  • Never use an old connector when installing a new range.
  • Flare union adapter for connection to gas supply line (3/4″ or 1/2″ NPT × 1/2″ I.D.)
  • Flare union adapter for connection to pressure regulator on range (1/2″ NPT × 1/2″ I.D.)
  • Liquid leak detector or soapy water.
  • (UL Listed 40 AMP)
    • 4-Wire Cord 4′ long OR
    • 3-Wire Cord 4′ long
  • Teflon: Registered trademark of DuPont

BEFORE YOU BEGIN

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • IMPORTANT – Remove all packing material and literature from oven before connecting gas and electrical supply to range.
  • IMPORTANT – To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
  • Note to Installer – Be sure to leave these instructions with consumer.
  • Note to consumer – Keep these instructions for future reference.
  • Servicer – The electrical diagram is in an envelope attached to the back of the range.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under warranty.
  • Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4″ thick plywood or similar
  • insulator is placed between the range and carpeting.

Mobile Home – Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280  (formerly the Federal Standard for Mobile Home Construction and Saftey, Title 24, HUD Part 280). When such standard is not  applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes. In Canada, the installation of this range must conform with the current standards CAN/CSA- A240-latest edition, or with local codes.  When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.

DIMENSIONS

DIMENSIONS AND CLEARANCES
Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.  Allow 30″ (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24″ (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4″ (6.4 mm) thick flame-retardant mill board covered with no less than No. 28 MSG sheet metal (.015″ [.38 mm thick), .015 (38 mm) thick stainless steel, .025″ (0.64 mm) aluminum or .020″ (0.5 mm) copper. Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance. For island installation. maintain 2-1/2″ minimum from cutout to back edge of countertop and 3″ minimum from cutout to side edges of countertop.

DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONSGE-APPLIANCES-P2B935YPFS-30-Inch-
Dual-Fuel-Smart-Range-fig-1 \(6\) CAUTION To prevent drafts from affecting burner operation, seal all openings in floor under appliance and behind appliance wall.

CONVERTING TO PROPANE GAS (OR CONVERTING BACK TO NATURAL GAS FROM PROPANE)
This range leaves the factory set for use with natural gas. If you want to convert to propane gas, the conversion must be performed by a qualified propane gas installer. The conversion orifices and instructions can be found on back of the range. Keep these instructions and all orifices in case you want to convert back to natural gas.

INSTALLATION

INSTALLATION AT HIGH ALTITUDE
Over 6000ft, product configured for natural gas or propane requires installation of kit (WB28X29254 for natural gas and WB28X29255 for propane gas). Follow the instructions included with the kit.

ELECTRICAL REQUIREMENTS

WARNING This appliance must be properly grounded.
WARNING All new constructions, mobile homes, recreational vehicles and installations where local codes do not allow grounding through neutral, require a 4-conductor UL-listed range cord.
WARNING To prevent fire or shock, do not use an extension cord with this appliance.
WARNING To prevent shock, remove house fuse or open circuit breaker before beginning installation.
We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you how to disconnect power from the range. You must use a single-phase, 120/208 VAC or 120/240 VAC, 60 hertz electrical system. If you connect to aluminum wiring, properly installed connectors approved for use with aluminum wiring must be used. Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range. When installing an electric range in new construction, mobile home, recreational vehicle, or an area where local codes prohibit grounding through the neutral conductor, refer to the section on four-conductor branch circuit connections. Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a hazardous condition. If there are no local codes, your oven must be wired and fused to meet the National Electrical Code, PA No. 70 – latest edition, available from the National Fire Protection Association. This appliance must be supplied with the proper voltage and frequency, and connected to an individual, properly grounded, 30 amp (minimum) branch circuit protected by a circuit breaker or time-delay fuse. Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device. A cord kit rated at 30 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 1% diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable. The rating plate is located on the oven frame or on the side of the drawer frame.
NOTE: Use of automatic, wireless or wired external switches that shut off power to the appliances, are not recommended for this product.

POWER CORD AND CONDUIT INSTALLATION

  • A. Remove wire cover (on the back of range) by removing screws using a 1/4″ nut driver. You can access the terminal block by either removing a terminal block cover (on some models) or the wire cover. Do not discard these screws.
  • B. For power cord and 1″ conduit only, remove the knockout ring (1⅗*) located on bracket directly below the terminal block. To remove the knockout, use a pair of pliers to bend the knockout ring away from the bracket and twist until ring is removed.
  • C. For power cord installations only (see the next step if using conduit), assemble the strain relief in the hole. Insert the power cord through the strain relief and tighten. Allow enough slack to easily attach the cord terminals to the terminal block. If tabs are present at the end of the winged strain relief, they can be removed for better fit.
    • NOTE: Do not install the power cord without a strain relief. The strain relief bracket MUST be installed before reinstalling the rear range wiring cover.
  • D. For 3/4″ conduit installations only, purchase a squeeze connector matching the diameter of your conduit and assemble it in the hole. Insert the conduit through the squeeze connector and tighten. Allow enough slack to easily attach the wires to the terminal block.
    • NOTE: Do not install the conduit without a squeeze connector. The squeeze connector MUST be installed before reinstalling the rear terminal block.GE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-Range-fig-1 \(12\)

3-WIRE INSTALLATION (GROUND IS THROUGH THE NEUTRAL WIRE)

WARNING Shock Hazard

  • The neutral wire and ground strap must be connected as shown below for the range to be properly grounded. Do not remove the ground strap. Failure follow this instruction may result in potential shock hazard.

WARNING Fire hazard
Terminal block screws must be securely tightened. Failure to do so may result in potential fire hazard.

FOR POWER CORD INSTALLATION

  • A. Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
  • B. Do not cut or remove the ground strap.
  • C. Insert the 3 screws through each power cord  terminal ring and back into the terminal block. Becertain the white wire is in the center. Securely tighten each screw (35 to 50 in-Ibs.)

FOR CONDUIT INSTALLATION

  • A. Loosen the 3 lower screws on the terminal block. Do not loosen the upper screws.
  • B. Do not cut or remove the ground strap.
  • C. Insert the bare wire tip (insulation stripped 5/8″) into the bottom terminal block openings. Be certain the white wire is in the center. On certain models, the wire must be inserted through an opening in the ground strap Securely tighten each screw onto each wire (35 to 50 in-Ibs.).
  • D. Reinstall terminal block cover.
    • NOTE: Aluminum building wire may be used but it must be rated for the correct amperage and voltageGE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-Range-fig-1 \(13\)

4-WIRE INSTALLATION (SEPARATE GROUND WIRE)

WARNING
The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The grounding lead must be connected to the frame of the range with the ground plate and the green ground screw.

FOR POWER CORD INSTALLATION

  • A. Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
  • B. Remove the ground screw and ground plate and retain them.
  • C. Cut the ground strap below the terminal block and discard the lower section.
  • D. Insert the ground screw through the ground plate (removed earlier) and back into therange frame. Tighten securely, but do not over-tighten (15 to 20 in-Ibs.)
  • E. Insert the 3 terminal screws through each power cord terminal ring and back into the  terminal block. Be certain the white wire isin the center. Securely tighten each screw (35 to 50 in-Ibs.
  • F. Reinstall terminal block cover.

FOR CONDUIT INSTALLATION

  • A. Remove the 3 lower screws from the terminal block. Do not loosen the upper screws.
  • B. Remove the ground screw and ground plate and retain them.
  • C. Cut the ground strap below the terminal block and discard the lower section.
  • D. Insert the bare ground bare wire tip (insulation stripped 5/8″) between the range frame and the ground plate (removed earlier) and secure it in place with the ground screw. Tighten securely, but do not over-tighten (15 to 20 in-Ibs).
  • E. Insert the wire tips (insulation stripped 5/8″) into the bottom terminal block openings. Be certain  the white wire is in the center. On certain models, the wire must be inserted through anopening in the ground strap. Securely tighten each screw onto each wire (35 to 50 in-Ibs.)
  • F. Reinstall terminal block cover.

NOTE: Aluminum building wire may be used but it must be rated for the correct amperage and voltage..

Before-Power Cord and Conduit

After-Conduit

GAS SUPPLY

WARNING
Fire Hazard: Do not use a flame to check for gas leaks.
WARNING Explosion Hazard: Do
not exceed 25 ft-Ibs of torque when making gas line connections. Overtightening may crack the pressure regulator resulting in fire or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows:
Natural Gas:

  • Minimum pressure: 6″ of Water Column
  • Maximum pressure: 13″ of Water Column

Propane Gas:

  • Minimum pressure : 11″ of Water Column
  • Maximum pressure: 13″ of Water Column

If you are not sure about the inlet pressure contact local gas supplier.  Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA International- certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection. If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.

To prevent gas leaks, put pipe joint compound on. or wrap pipe thread tape with Teflon’ around, all male (external) pipe threads.

  • A. Install a manual shut-off valve in the gas line in an easily accessed location outside of the range. Make sure everyone operating the range knows where and how to shut off the gas supply to the range.
  • B. Install male 1/2″ flare union adapter to the 1/2″ NPT internal thread at inlet of regulator. Use a backup wrench on the regulator fitting to avoid damage.
  • C. Install male 1/2″ or 3/4″ flare union adapter to the NPT internal thread of the manual shut-off valve, taking care to back-up the shut-off valve to keep it from turning.
  • D. Connect flexible metal appliance connector to the adapter on the range. Position range to permit connection at the shut-off valve.
  • E. When all connections have been made, make sure all range controls are in the off position and turn on the main gas supply valve.

Use a liquid leak detector at all joints and connections to check for leaks in the system. When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut- off valve from the gas supply piping. When using pressures of 1/2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing  the individual shut-off valve.When checking for proper operation of the regulator, the inlet pressure must be at least 1″ greater than the operating (manifold) pressure as given on rating label of product.
Teflon: Registered trademark of DuPont

CONNECTOR HOOKUPGE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-Range-
fig-1 \(16\) Installer: Inform the consumer of the location of the gas shut-off valve.

SURFACE BURNERS

WARNING Fire or Explosion Hazard:
Do not operate the burner without all burner parts in place.

  • A. Burners – Place surface burners into corresponding positions on cooktop.
  • B. Caps – Place caps on proper size burner.
  • C. Grates – The left and right grates areinterchangeable. Place the grates on the cooktop. GE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-Range-fig-1 \(18\)

CHECK SURFACE BURNERS

Push and turn a knob to the LITE position. A clicking sound indicates proper operation of the ignition system. When lighting any burner, sparks will appear at all burners but gas flows  from only the one selected. Once air is purgedfrom the supply line, burner should light within 4 seconds. After burner lights, rotate the knob out of the LITE position. Try each burner in succession until all burners have been checked.

Quality of Flames
Determine the quality of flames visually. Normal burner flames should look like (A) or (B).

Long, bright yellow flames are not normal. Normal flames may show signs of an orange tint when well heated or signs of flickering orange due to particles in the gas or air.

INSTALL AND CHECK ANTI-TIP DEVICE

AWARNING Never completely
remove the leveling leg as the range will not be secured to the anti-tip device properly. Follow instructions supplied with ANTI-TIP bracket.

LEVEL THE RANGE

WARNING Never completely
remove the leveling leg as the range will not be secured to the anti-tip device properly.

  • A. Plug in the unit.
  • B. Measure the height of your countertop at the rear of the opening (X).
  • C. Adjust two rear leveling legs so that the rear of cooktop is at the same height or higher than the counter (Y).
  • D. Slide unit into place.
  • E. Install oven shelves in the oven and position the range where it will be installed.
  • F. Check for levelness by placing a spirit level on one of the oven shelves. Take two readings with the level placed diagonally first in one direction and then the other.
  • G. Adjust front leveling legs until the range is level.
  • H. Look under the unit and verify that the rear leg is fully engaged with the anti-tip device. If not, remove the unit and adjust the height of the rear leg so that it is properly engaged.GE-APPLIANCES-P2B935YPFS-30-Inch-Dual-Fuel-Smart-Range-fig-1 \(20\)

FINAL INSTALLATION CHECKLIST

  • Check to make sure the circuit breaker is closed (RESET) or the circuit fuses are replaced.
  • Be sure power is in service to the building.
  • Check that all packing materials and tape have been removed.
  • This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic.
  • Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
  • Check that the door and drawer are parallel to each other and that both operate smoothly. If they do not, see the Owner’s Manual for proper replacement.
  • Check to make sure that the rear leveling leg is fully inserted into the Anti-Tip bracket and that the bracket is securely installed.

OPERATION CHECKLIST

  • Check that the oven control operates properly. If the oven control does not operate properly, recheck the wiring connections.
  • Be sure all range controls are in the OFF position before leaving the range.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

GE Appliances User Manuals

Related Manuals