Rinnai RXP199i, RXP160i Condensing Tankless Water Heater Owner’s Manual
- July 27, 2024
- Rinnai
Table of Contents
Rinnai RXP199i, RXP160i Condensing Tankless Water Heater
Product Usage Instructions
Installation
- Choose the appropriate venting option and size based on your installation type.
- Ensure proper clearances as specified in the manual for safe installation.
- Connect the gas supply following the recommended pressure ranges for natural gas or propane.
- Mount the water heater securely using the provided wall mounting bracket.
Maintenance
- Regularly check for any buildup or blockages in the venting system.
- Inspect the water flow control components for any signs of wear or damage.
- Monitor the efficiency of the heater and adjust settings as needed for optimal performance.
Troubleshooting
- If you encounter any error codes or issues, refer to the user manual for troubleshooting steps.
- Contact customer support if problems persist or if professional assistance is required.
FAQ
- Q: What should I do if the heater displays an error code?
- A: Error codes indicate specific issues with the unit. Refer to the manual for error code meanings and troubleshooting steps.
- Q: Can I install the water heater outdoors?
- A: Yes, the product is suitable for outdoor installation with the appropriate vent cap.
- Q: How often should I schedule maintenance for the water heater?
- A: Regular maintenance checks are recommended at least once a year to ensure optimal performance and longevity of the unit.
FLEXIBLE VENTING OPTIONS
- Concentric or Schedule 40 PVC/CPVC
- Direct Vent (Concentric and Twin Pipe)
- Non-Direct Vent (Room Air)
- Common Vent (Direct Vent and Room Air)
- Maximum Equivalent Vent Lengths:
Twin Pipe (PVC/CPVC and PP)
Vent Sizes | 2 in. (51 mm) | 3 in. (76 mm) |
---|---|---|
Vent Lengths | 75 ft (23 m) | 150 ft (46 m) |
Concentric
Vent Sizes | 2 in. X 4 in. | 3 in. X 5 in. |
---|---|---|
Vent Lengths | 75 ft (23 m) | 150 ft (46 m) |
EASE OF INSTALLATION AND SERVICEABILITY
- Smart-Sense: Adaptive gas valve technology – No gas conversion kit required.
- Versa-Vent: Outdoor vent cap adapts to any SENSEITM RX Series model for outdoor installation.
- Smart Connect: Allows you to connect your phone or tablet to SENSEITM RX Series Via Bluetooth® using Rinnai CentralTM app.
- Quick-Flush: Provides an efficient flushing procedure to make periodic preventive maintenance a simple task to perform.
Warranty
- Heat Exchanger: 15 years or 12,000 operation hours, whichever occurs first
- All Other Parts and Components: 5 years
- Reasonable Labor: 5 years Requires product to be registered within 90 days of installation or labor warranty defaults to 1 year
Safety Devices
- Flame Failure – Flame Rod, Boiling Protection, Combustion Fan RPM Check,
- Over Current – Glass Fuse, Remaining Flame (OHS) and Automatic Frost Protection
Included with Purchase
- Tankless Water Heater, Wall Mounting Bracket, Vent Screens (x2), Screws (x2), Self-Tapping Screws (x4) and Thermal Bypass Valve
Additional Features
- Mobile Home Certified
- Ultra Low NOx
- Tankless Rack System Compatible
- 1/2 in. (13 mm) Gas Line Compatible
- Complies with South Coast Air Quality Management District 14 ng/J or 20 ppm NOx Emission Levels
- EZConnect—1 RXP and 1 RX as System
OPTIONAL ACCESSORIES
Description| Part Number| Description| Part Number|
Description| Part Number
---|---|---|---|---|---
Isolation Valves and PRV| MIVK-T-LW| Pipe Cover| PCD11-SHS| Controllers|
MC-601-BK/W, MC-195T-US
Outdoor Vent Cap| RXOVC| Recess Box for SENSEITM RX Series| RGBCTWHRX|
Condensate Neutralizer| 804000074
Dedicated Return with Isolation Valves and PRV| 107000639| Bottom Plate for
Pipe Cover| 109001364| Scale Cutter| 103000038
Retrofit Door for RX in RGB-CTWH-4| 104000335| Wireless Module| RWM200|
Scale Cutter Refill| 103000039
Retrofit Door for RX in RGB-CTWH-3, 2, 1| 104000336| Recirculation Push
Button| RPB200| OPU Switch| REU-OPU3
Gas Conversion Kit (Labels Only)| 104000330| EZConnect Cable| REU-EZC-3|
Leak Detection Kit| RXLeakKit
New—for SENSEITM RX/CX Series Water Heaters
TECHNICAL SPECIFICATIONS
SENSEITM RXP TECHNICAL SPECIFICATIONS
SPECIFICATION| RXP199i| RXP160i
Dimensions – w, h, d| 18.5 in. x 25.8 in. x 11.4 in. (470 mm x 654 mm x 290
mm)
Minimum Gas Consumption Btu/h| 15,000
Maximum Gas Consumption Btu/h| 199,000| 160,000
Flow Rate1 (Min-Max)| 0.13 – 11.0 GPM (0.5 – 42 L/min)| 0.13 – 9.0 GPM (0.5 –
34 L/min)
Weight| 58 lb (26 kg)| 57 lb (26 kg)
Sound Level| 49 dB| 48 dB
Electrical| Normal| 98 W| 73 W
Normal with
Pump Operation
| 170 W| 149 W
Standby| 1.3 W
Freeze
Protection
| 174 W
Max Current| 4 Amps
Fuse| 10 Amps
Temperature
| · Minimum: 98° F (37° C) Default (Crossover Mode: 120°F (49°C))
· Maximum: 120° F (49° C) Default
140° F (60° C) With Parameter Adjustment
By-Pass Flow Control| Electronic
Gas Supply Pressure2| · Natural: 3.5 in. w.c. – 10.5 in. w.c.
· Propane: 8.0 in. w.c. – 13.5 in. w.c.
Ignition System| Direct Electronic Ignition
Electronic
Connections
| · Appliance: AC 120 Volts, 60Hz.
· Temperature Controller: DC 12 Volts (Digital)
Water Supply Pressure| · Minimum: 15 PSI (Recommended 50 PSI for max performance)
· Maximum: 150 PSI
Service Connections
| · Gas Supply: 3/4 in. (19 mm) NPT
· Cold Water Inlet: 3/4 in. (19 mm) NPT
· Hot Water Outlet: 3/4 in. (19 mm) NPT
· Condensate Drain: 1/2 in. (13 mm) NPT
Clearances
| · Top: 2 in. (51 mm)* · Back: 0 in.
· Bottom/Ground: 12 in. (305 mm) · Sides: 2 in. (51 mm)***
· Front: 0 in.** · Vent: 0 in.
- 0 in. from vent components.
- Clearance for servicing is 24 in. (610 mm) in front of the water heater.
- Add 0.25 in. (6.35 mm) for the recess box.
- Activation flow rate may vary slightly depending on the temperature setting and the inlet water temperature.
- The maximum gas supply pressure must not exceed the value specified by the manufacturer.
Rinnai products are continually being updated and improved; therefore, specifications are subject to change without prior notice.
SENSEITM RXP WATER FLOW CURVE
Flow curves apply only to incoming water temperatures of 70° F (21° C) or
less. For incoming water temperatures greater than 70° F (21° C), please
contact Rinnai.
NOTE: Maximum flow rates may vary based on set temperature, Delta T and altitude.
DIMENSIONS
SENSEITM RXP DIMENSIONS
FRONT
SIDE
Vent Connection
- 2 in. (51 mm) nominal PVC/CPVC/PP or 3 in./5 in. Concentric.
BOTTOM
Connection | in. | mm | |
---|---|---|---|
COLD | A | 0.37 | 9 |
B | 3.60 | 91 | |
HOT | C | 5.10 | 130 |
D | 6.20 | 158 | |
GAS | E | 5.60 | 142 |
F | 2.83 | 72 | |
DRAIN | G | 7.13 | 181 |
H | 5.32 | 135 |
SENSEIRXP PUMP PERFORMANCE AND PUMP + TANKLESS PERFORMANCE CURVE
Recirculation Pump Control
- Smart-Circ.™ “learns” users’ hot water patterns to activate recirculation.
- Manual schedule selection is available with Accessory controllers (MC-195T or Wi-Fi module.
Internal Multi-Speed DC Pump
- The integrated pump allows for recirculation through a dedicated return line or crossover with a thermal bypass valve.
Maximum Recirculation Pipe Lengths
- 400 equivalent feet for 3/4 in. pipe diameter
- 100 equivalent feet for 1/2 in. pipe diameter
Take equivalent elbow lengths into consideration when calculating pipe length.
For dedicated return lines: Total length includes both hot water supply
and dedicated return lines.
Cross-over mode: Total length includes both hot water supply and cold
water piping length from the tankless water heater to the thermal bypass
valve. Cross-over mode requires the use of a thermal bypass valve (included).
CONTACT
- Rinnai America Corporation
- 103 International Drive, Peachtree City, GA 30269
- 1-800-621-9419
- rinnai.us
- ©2024 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice.
- Local, state, provincial, federal and national fuel gas codes must be adhered to before and upon installation.
References