olympia electronics ZLD-44-EM-ADR Addressable Self Testing Maintained Emergency Illumination Signs Instruction Manual
- June 12, 2024
- olympia electronics
Table of Contents
- Package Contents
- General
- Indications LED Status
- Installation Instructions
- Programming the address of a luminaire
- Surface mounting on a Wall with A-1134 base (Included in the package)
- Οptional Mounting Methods (Upon Request)
- Dimensional Drawings (mm)
- Battery Replacement
- Technical Characteristics
- LED Characteristics
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
European
manufacturers
ZLD-XX/EM/ADR
ADDRESSABLE
SELF TESTING MAINTAINED
EMERGENCY ILLUMINATION SIGNS
Thank you for your trust in our products Olympia Electronics – European manufacturer
Package Contents
1 | Luminaire |
---|---|
2 | Mounting accessories |
3 | Manual |
4 | Pictograms |
General
These devices are used indoors (ta 40 C) in places where emergency light is
needed. Each device must be permanently connected to mains power supply. In
normal operation the battery is charging. In case of a mains power supply
failure, the device enters emergency mode and the illumination LED turns on.
When the mains power supply is restored the device turns to normal operation.
Manual Operational Test
By pressing the test button an operation test is initiated. The light source
and the emergency circuit of the device are tested. The manual test can be
conducted only if the mains power supply and the battery are connected. During
this test period all indications LED are OFF.
Tests
The illumination source and the autonomy tests are programed by the control
panel.
The tests results are send to the control panel.
If the luminaire is not connected to the panel, the following automatic tests
executed:
Automatic Operational Test
This test includes all the operations that are provided in manual operational
test and is conducted automatically every 15 days and lasts 3 seconds.
Automatic Autonomy Test
The Automatic Autonomy Test is conducted every 6 months and measures the
device’s back up operation and emergency duration. In order to be performed,
the mains power supply and the battery should be connected and fully charged.
If the battery is not fully
charged, the test is postponed until the battery is completely charged. If
during this test, the autonomy is less than nominal then the battery fault led
turned on continuously and the battery must be replaced.
Indications LED Status
Resetting Errors
Push the Test button for more than 5 seconds, to delete all the indicated LED
errors. Then the device enters regularoperation mode.
Changing The Operating Mode
Press and hold the TEST button for more than 5 seconds. The luminaire will
erase first the errors (3 LED indicators will light in succession) and after 2
seconds the LED Lamp Fault will remain lit steadily. When the TEST button is
released, the luminaire will change between maintained or non maintained mode.
The change is recorded permanently in it’s memory.
Addressable Communication
The luminaires can be connected to the addressable panels of Olympia
Electronics. For address operations refer to the installation manual of the
panel. For address connections see page 2.
ΑΤΤΕΝΤΙΟΝ!!!
- Operations for installation, maintainance or testing must be done by authorized personnel only.
- Always use in any case round mains cable, with a diameter of 5-10mm (H05RN-F type 2x1mm² or any other type, at least equal to it’s mechanical and electrical properties). ATTENTION!! The cable must not be deformed in any way (This requirement is important to ensure the ΙΡ rating).
- The device must be connected to the mains power supply through a circuit breaker that is depends on the total line’s power load.
- In case of battery replacement, it must be replaced by the same type, by the manufacturer or a competent person.
- In case of inactive use for a period greater than 2 months, disconnect the battery by pulling out the battery’sconnector.
- It is not allowed to discard batteries into common trash bins, they must be discarded only in battery recycling points. Do not incinerate.
Installation Instructions
Programming the address of a luminaire
To program or change the address of a luminaire you must connect the luminaire to the panel alone and do the following steps:
- The luminaire must not be connected with the mains power supply not with the battery.
- One end of the cable is connented to the luminaire and the other end to the panel.
- You must go to the menu: TECHNICIAN MENU => SETTINGS=> CHANGE ADDRESS POINT
- Set the new address using the UP and DOWN keys and press enter when done.
Surface mounting on a Wall with A-1134 base (Included in the package)
Single sided luminaire
Οptional Mounting Methods (Upon Request)
Dimensional Drawings (mm)
Battery Replacement
It can be done only by a competent person and after the mains interruption.
Remove the old battery and place a new one of the same type and
characteristics and assembly the luminaire.
WARNING!! Use a maximum torque of 0,25Νm to tighten the screws.
NOTE: LED= Light Emitting Diode
LABELING EXPLANATION:
X: Self contained
1: Maintained operation ()
A: Including test device
B: Including remote test mode
C: Including inhibiting mode
G: Internally illuminated safety sign
180: 3 hours duration
1X A B C G 1 8 0
() Maintained operation: The luminaire lights its illumination source, when
it is powered by the mains power supply or not.
Non Maintained operation: The luminaire lights its illumination source, only
in mains power supply’s failure.
ATTENTION!!!
The light source of this luminaire is not replaceable when the light source
reaches its end of life the whole luminaire shall be replaced.
Technical Characteristics
OPERATION VOLTAGE | ZLD-28/EM/ADR | ZLD-34/EM/ADR | ZLD-44/EM/ADR |
---|---|---|---|
MAXIMUM POWER CONSUMPTION | 220-240V AC / 50-60Hz | ||
SUPPLY CURRENT | 3.8W / 6.5VA | 4W / 6.7VA | 4.3W / 6.9VA |
U-OUT | 28mA | 29mA | 30mA |
EOFi | 1.3 | 0.6 | 0.62 |
WIRE CROSS SECTION | 0.3mm² – 3.3mm² (22-12AWG) | ||
BATTERY (Ni-MH) | 3.6V / 1.5 Ah | ||
INSULATION BETWEEN SUPPLY & BATTERY CIRCUIT | Basic insulation | ||
BATTERY PROTECTION | Deep discharge and overcharge protection / the control |
gear will recharge the battery normally after the test of 22.3
MIN MAX. DISCHARGE VOLTAGE| 3 – 4.2V
MIN MAX. DISCHARGE CURRENT| 270 – 360mA| 270 – 370mA| 255 – 360mA
Rated CURRENT @3.6V| 310mA| 315mA| 290mA
MIN MAX. CHARGE CURRENT| 140 – 165mA
MAX CHARGE VOLTAGE| 5V
INDICATIONS| LED Charge, Lamp Fault LED, Battery Fault LED
CHARGE TIME| 3h
MINIMUM DURATION| 24 hours
LIGHT SOURCE| 18 white LEDs| 21 white LEDs| 24 white LEDs
LIGHT SOURCE LUMINOUS FLUX (MAINS / EMERGENCY)| 125lm/125lm| 145lm/125lm|
170lm/125lm
DEGREES OF COVER PROTECTION| IP40
PRODUCED IN ACCORDANCE WITH| EN 60598-1, EN 60598-2-22, ΕΝ 55015,
VIEWING DISTANCE| ΕΝ 61547, ΕΝ 61000-3-2, ΕΝ 61000-3-3
OPERATION TEMPERATURE RANGE| 16m| 30m| 38m
RELATIVE HUMIDITY| 5 to 40 °C
CONSTRUCTION MATERIAL| Aluminum, Acrylic Plate, ABS/PC
EXTERNAL DIMENSION (L x W x H)| Up to 95%
WEIGHT| Aluminum, Acrylic Plate, ABS/PC
GUARANTEE| 290 x 38 x 172 mm| 350 x 38 x 242 mm| 450 x 38 x 295 mm
CONTROL GEAR WITH AUTOMATIC| 780gr.| 1145gr.| 1585gr.
TEST FUNCTION| 3 years (1 year for the battery)
Controlgear classification in accordance with IEC 62034: with automatic test
function
The controlgear is suitable for LED modules only
The controlgear has mains-connected windings of transformer
The controlgear is proof against supply voltage polarity reversal
The lamp controlgear relies upon the luminaire enclosure for protection
against accidental contact with live part (7.2 BS EN 61347-2-7) Integrated SPD
LED Characteristics
MANUFACTURER| | Olympia Electronics S.A.|
---|---|---|---
MODEL NUMBER| 1111153| 1211153| 1311153
VOLTAGE RANGE| | 8.5- 10.5V DC|
NOMINAL POWER| 1200mW| 1400mW| 1600mW
CONNECTIONS| Non reversible| connection between main pcb and led module
Warranty
Olympia Electronics guarantees the quality, condition and operation of the
goods. The period of warranty is specified in the official catalogue of
Olympia Electronics and also in the technical leaflet, which accompanies each
product. This warranty ceases to exist if the buyer does not follow the
technical instructions included in official documents given by Olympia
Electronics or if the buyer modifies the goods provided or has any repairs or
re-setting done by a third party, unless Olympia Electronics has fully agreed
to them in writing. Products that have been damaged can be returned to the
premises of our company for repair or replacement, as long as the warranty
period is valid.
Olympia Electronics reserves the right to repair or to replace the returned
goods and to or not charge the buyer depending on the reason of defection.
Olympia Electronics reserves the right to charge or not the buyer the
transportation cost.
72nd km. O.N.R. Thessaloniki-Katerini
P.C. 60300 P.O. Box 06 Εginio Pierias Greece
www.olympia-electronics.com
info@olympia-electronics.gr
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>