CHAUVET DJ Intimidator Free Spot 60 ILS Wireless Battery Moving Head User Manual
- June 12, 2024
- Chauvet DJ
Table of Contents
Intimidator Free Spot 60 ILS
Wireless Battery Moving Head User Manual
Before You Begin
What Is Included
- Intimidator Free Spot 60 ILS
- Power cable
- Omega bracket
- Quick Reference Guide
Unpacking Instructions
Carefully unpack the product immediately and check the container to make sure
all the parts are in the package and are in good condition.
Claims
If the box or the contents (the product and included accessories) appear
damaged from shipping, or show signs of mishandling, notify the carrier
immediately, not Chauvet. Failure to report damage to the carrier immediately
may invalidate the claim. Keep the box and contents for inspection.
For other issues, such as missing components or parts, damage not related to
shipping, or concealed damage, file a claim with Chauvet within 7 days of
delivery.
Text Conventions
Convention | Meaning |
---|---|
1–512 | A range of values |
50/60 | A set of values of which only one can be chosen |
Settings | A menu option not to be modified |
< ENTER> | A key to be pressed on the product’s control panel |
ON | A value to be entered or selected |
Symbols
Symbol | Meaning |
---|
| Electrical warning. Not following these instructions may cause electrical
damage to the product, accessories, or the user.
| Critical installation, configuration, or operation information. Not
following these instructions may make the product not work, cause damage to
the product, or cause harm to the operator.
| Important installation or configuration information. The product may
not function correctly if this information is not used.
| Useful information.
Safety Notes
ALWAYS:
- Connect to a grounded circuit.
- Connect to operating voltages as specified on the product’s spec sticker.
- Disconnect from power before replacing the fuse.
- Disconnect from its power source during periods of inactivity.
- Use a safety cable when suspending overhead.
- Heed all restrictions and warnings on the spec sticker.
- Mount in a location with at least 20 in (50 cm) of ventilation.
- Replace the fuse with the same type and rating.
In the event of a serious operating problem, stop using immediately.
DO NOT:
- Open this product or attempt any repairs. It contains no user-serviceable parts.
- Look at the light source when the product is on.
- Use if the power cord is crimped or damaged.
- Disconnect by pulling on the power cord.
- Allow flammable materials close to the product when it is operating.
- Touch the housing when it is on.
- Block any ventilation holes/slots in the housing.
- Connect to a dimmer or rheostat.
- Carry the product by its power cord.
- Operate in temperatures higher than 104°F (40°C).
- Expose to environments that exceed the Ingress Protection (IP) rating.
- Expose to rain or moisture.
- Use outdoors.
- Submerge.
- Expose to corrosive environmental conditions such as temperature, humidity, salinity, pressure, radiation, or shock.
- Set this product on a flammable surface.
Battery Charge Notes
Rechargeable lithium-ion batteries are potentially hazardous and can present a
serious FIRE HAZARD, SERIOUS INJURY and/or PROPERTY DAMAGE if damaged,
defective, or improperly used.
ALWAYS:
- Charge using a manufacturer-provided charger while the product is powered off.
- Charge the battery in temperatures between 32°-95°F (0°-35°C).
- Allow a depleted battery to charge for a few minutes before turning on the product. If the battery is completely discharged, the device cannot be turned on immediately when the charger is connected.
- Keep at least 3 ft (1 m) distance to any heat source and away from flammable materials.
- Keep the lid of any charging case open while charging.
- Keep batteries away from children.
- Store batteries between 40-60% charge.
- Follow local regulations when disposing of batteries.
- Replace with an authentic Chauvet battery.
DO NOT:
- Continue charging if the battery becomes hot, smokes, swells, or gives off an odor during charging.
- Leave the product unattended while charging.
- Deplete the battery below 10%.
- Charge the battery in a closed container.
- Charge for more than 24 hours.
FCC Statement of Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Warning for North America and Australia
Warning! This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20 cm between the radiator and the user.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Disclaimer
Chauvet believes that the information contained in this manual is accurate in
all respects. However, Chauvet assumes no responsibility and specifically
disclaims any and all liability to any party for any loss, damage or
disruption caused by any errors or omissions in this document, whether such
errors or omissions result from negligence, accident or any other cause.
Chauvet reserves the right to revise the content of this document without any
obligation to notify any person or company of such revision, however, Chauvet
has no obligation to make, and does not commit to make, any such revisions.
Download the latest version from
www.chauvetdj.com.
The works of authorship contained in this manual, including, but not limited
to, all designs, text, and images are owned by Chauvet.
© Copyright 2023 Chauvet & Sons, LLC. All rights reserved.
Electronically published by Chauvet in the United States of America.
Chauvet, the Chauvet logo, and Intimidator Free Spot 60 ILS are registered
trademarks or trademarks of Chauvet & Sons LLC. (d/b/a Chauvet and Chauvet
Lighting) in the United States and other countries. Other company and product
names and logos referred to herein may be trademarks of their respective
companies.
**** Keep this User Manual for future use.
Introduction
Product Overview
Product Dimensions
Setup
AC Power
The Intimidator Free Spot 60 ILS has an auto-ranging power supply, and it can
work with an input voltage range of 100 to 240 VAC, 50/60 Hz.
To determine the product’s power requirements (circuit breaker, power outlet,
and wiring), use the current value listed on the label affixed to the
product’s back panel or refer to the product’s specifications chart. The
listed current rating indicates the product’s average current draw under
normal conditions.
- **** Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.
- To eliminate unnecessary wear and improve its lifespan, completely disconnect the product from power via breaker or by unplugging it during periods of non-use.
**** Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.
Fuse Replacement
- Disconnect the product from power.
- Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
- Pry the fuse holder out of the housing.
- Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating.
- Insert the fuse holder back in place and reconnect power.
- Disconnect the product from the power outlet before replacing the fuse.
- Always replace a blown fuse with one of the same type and rating.
Battery Power
The Intimidator Free Spot 60 ILS comes with a rechargeable lithium battery for
cable-free operation.
Charging the Battery
The battery charges whenever the Intimidator Free Spot 60 ILS is plugged into
a power source using the included power cable. If the product is plugged in
and not in operation, make sure the product is turned off.
- **** Before charging the product, read and follow the safety recommendations in the Safety Notes.
- The LED indicator light will flash if units are overcharged.
- DO NOT use the Intimidator Free Spot 60 ILS on full power mode while being charged/plugged into a power source, as the unit will get extremely hot.
Battery Life Indicator
The numbers displayed on the battery indicator show how much battery life
remains available. The battery indicator will display up to four (+) signs
while charging.
Battery Run Time
Maximum Run Time | Recharge Time |
---|---|
Up to 8 hours | 6.75 hours |
Mounting
Before mounting the product, read and follow the safety recommendations
indicated in the Safety Notes.
Orientation
The Intimidator Free Spot 60 ILS may be mounted in any position; however, make
sure adequate ventilation is provided around the product.
Rigging
- Before deciding on a location for the product, always make sure there is easy access to the product for maintenance and programming purposes.
- Make sure adequate ventilation is provided around the product.
- Mount the product on a structure or surface that can support the product’s weight (see the Technical Specifications for weight information).
- Always use a safety cable when mounting the product overhead. Mount the product securely to a rigging point (e.g., an elevated platform or a truss).
- Use a mounting clamp of appropriate weight capacity when rigging the product onto a truss.
Mounting Diagram
Operation
Control Panel Operation
To access the control panel functions, use the four buttons located next to
the display. Please refer to the Introduction to see the button locations on
the control panel.
Button | Function |
---|---|
< MENU> | Exits from the current menu or function |
< UP> | Navigates upwards through the menu list and increases the numeric |
value when in a function
< DOWN>| Navigates downwards through the menu list and decreases the
numeric value when in a function
< ENTER>| Enables the currently displayed menu or sets the currently
selected value into the selected function
Menu Map
Refer to the Intimidator Free Spot 60 ILS product page on
www.chauvetdj.com for the latest menu map.
Main Menu | Programming Levels | Description |
---|---|---|
DMX Address | 001–499 | Selects DMX starting address |
Run Mode | DMX | 08CH |
10CH | 10-channel DMX mode | |
14Ch | 14-channel DMX mode | |
Slave | Slave 1–4 | Sets which slave unit(s) will mimic the master |
unit
ILS| ILS1–4| Sets ILS mode
AUTO| Sets the fixture to Auto mode
Sound| Sets the fixture to Sound mode
RF| Sets the fixture to connect via RF
Manual| Pan| 000–255| Adjusts the pan angle
Tilt| Adjusts the tilt angle
Color| Selects the color manually
Gobo| Selects the gobo manually
Gobo Rototate| Adjusts gobo rotation
Prism| Adjusts prism
Focus| Adjusts focus
Dimmer| Adjusts the brightness
Shutter| Adjusts the shutter
Setup| DFI| RX| Sets the product to receive D-Fi signal
TX| Sets the product to transmit D-Fi signal
OFF| Disables D-Fi mode
D-Fi Channel| 1–16| Sets D-Fi channel
Pan Reverse| OFF| Normal pan operation
ON| Reverse pan operation
Tilt Reverse| OFF| Normal tilt operation
ON| Reverse tilt operation
Screen Reverse| OFF| Normal display
ON| Reverse display
Pan Angle| 540| Selects the 540° pan angle range
360| Selects the 360° pan angle range
180| Selects the 180° pan angle range
Tilt Angle| 234| Selects the 234° tilt angle range
180| Selects the 180° tilt angle range
90| Selects the 90° tilt angle range
Totem Mode| OFF| Does not restrict the pan and tilt motion
UP| Restricts the pan and tilt motion for overhead mounting
DOWN| Restricts the pan and tilt motion for surface/ floor mounting
Sensitivity| 000–100| Sets the sound sensitivity in Sound mode
Main Menu| Programming Levels| Description
---|---|---
Setup| DMX Loss| Hold| Holds the last setting when DMX signal
is lost
Black| Blacks out the fixture when DMX signal is lost
Auto| Sets the fixture to Auto mode when DMX signal is lost
Sound| Sets the fixture to Sound mode when DMX signal is lost
Indicator| ON| Enables LED indicator
OFF| Disables LED indicator
Flash if DMX| ON| The LED indicator flashes when the unit is
connected to the DMX
OFF| The LED indicator flashes when the unit is disconnected from the
DMX
Runtime| 4 Hours| Adjusts the light and power consumption based on
the amount of time the fixture has been running
6 Hours
8 Hours
RF| Common| Enables control of the fixture using any RF remote
Bind| Enables control of the Intimidator Free Spot 60 ILS using only the
RF remote paired to the fixture
Off| Disables RF connection
RF Group| Group1–4| Sets which group of fixture the RF remote will
control
RF Bind| | Link the fixture to a single remote and displays
the ID of the linked remote.
Press < ENTER> then hold and press < BLACKOUT>.
The display will show “SUCCESS” (success) or “ERROR” (failure).
Follow Spot| OFF| Disables Follow Spot mode
ON| Enables fixture to be controlled via ILS command
Reset| NO| Resets individual functions or all functions from
startup
YES
Factory Reset| NO| Resets settings to factory default
YES
Sys Info| Ver:| V _| Displays the firmware version
Running Mode:| _| Displays the current running mode
DMX Address:| _| Displays the DMX address
Temperature:| _ °C| Displays the LED PCB temperature in °C
DFI:| _| Displays the D-Fi status
DMX Configuration
The Intimidator Free Spot 60 ILS works with a DMX controller. Information
about DMX is in the Chauvet DMX Primer available from the Chauvet website:
www.chauvetdj.com.
DMX Personality and Starting Address
When selecting a starting DMX address, always consider the number of DMX
channels the selected DMX mode uses. Choosing a starting address that is too
high could restrict access to some of the product’s channels.
The Intimidator Free Spot 60 ILS uses up to 14 DMX channels in a 14CH DMX
mode, which defines the highest configurable address to 499.
For more information about the DMX protocol, download the DMX Primer from:
www.chauvetdj.com.
To select the starting address, do the following:
- Press
- Press
. - Use
or <DOWN?> to select the starting address, from 001—-499. - Press
.
Gobos
DMX Values
08CH| 10CH| 14CH| Function| Value|
Percent/Setting
---|---|---|---|---|---
1| 1| 1| Pan| 000 255| 0–540°
–| –| 2| Fine pan| 000 255| Fine control of
panning
2| 2| 3| Tilt| 000 255| 0–234°
–| –| 4| Fine tilt| 000 255| Fine control of
tilting
–| –| 5| Pan/tilt speed| 000 255| Pan/tilt
speed, fast to slow
3| 3| 6| Color wheel| 000 006
007 013
014 020
021 027
028 034
035 041
042 048
049 055
056 062
063 189
190 221
222 223
224 255| White
Red
Orange
Yellow
Green
Blue
CTO
Cyan
Magenta
Color indexing
Color clockwise rotation, fast to slow
Stop
Color counter-clockwise rotation, slow to fast
4| 4| 7| Gobo wheel
(see Gobos)| 000 007
008 015
016 023
024 031
032 039
040 047
048 055
056 063
064 071
072 079
080 087
088 095
096 103
104 111
112 119
120 127
128 189
190 193
194 255| Open
Gobo 1
Gobo 2
Gobo 3
Gobo 4
Gobo 5
Gobo 6
Gobo 7
Gobo 7 shake, slow to fast
Gobo 6 shake, slow to fast
Gobo 5 shake, slow to fast
Gobo 4 shake, slow to fast
Gobo 3 shake, slow to fast
Gobo 2 shake, slow to fast
Gobo 1 shake, slow to fast
Open
Gobo clockwise rotation, slow to fast
Stop
Gobo counter-clockwise rotation, slow to fast
5| 5| 8| Gobo rotation| 000 007
008 119
120 231
232 255| No function
Gobo rotation, clockwise, slow to fast
Gobo rotation, counterclockwise, slow to fast
Gobo bounce, short to long
08CH| 10CH| 14CH| Function| Value|
Percent/Setting
---|---|---|---|---|---
6| 6| 9| Prism| 000 015
016 255| No function
3-facet prism
7| 7| 10| Focus| 000 255| Focus, large to
small
–| 8| 11| Dimmer| 000 255| 0–100%
8| 9| 12| Shutter| 000 003
004 007
008 076
077 145
146 215
216 255| Closed
Open
Strobe, slow to fast
Pulse strobe, slow to fast
Random strobe, slow to fast
Open
–| 10| 13| Function| 000 007
008 015
016 023
024 031
056 095
096 103
104 111
112 119
120 127
128 135
136 143
144 151
152 159
160 167
168 175
176 183
184 192
193 200
201 255| No function
Blackout on pan/tilt movement
Blackout on color wheel movement
Blackout on gobo wheel movement
No function
Pan reset
Tilt reset
Color wheel reset
Gobo wheel reset
No function
Prism reset
Focus reset
Reset all
No function
Run time from display menu setting
Runtime 4-hour mode
Runtime 6-hour mode
Runtime 8-hour mode
No function
–| –| 14| Movement macro| 000 007
008 023
024 039
040 055
056 071
072 087
088 103
104 119
120 135
136 151
152 167
168 183
184 199
200 215
216 231
232 247
248 255| No function Movement macro 1
Movement macro 2
Movement macro 3
Movement macro 4
Movement macro 5
Movement macro 6
Movement macro 7
Movement macro 8
Sound-active macro 1
Sound-active macro 2
Sound-active macro 3
Sound-active macro 4
Sound-active macro 5
Sound-active macro 6
Sound-active macro 7
Sound-active macro 8
Standalone Configuration
Set the product in one of the standalone modes to control without a DMX
controller.
**** Never connect a product that is operating in any standalone mode to a
DMX string connected to a DMX controller. Products in standalone mode may
transmit DMX signals that could interfere with the DMX signals from the
controller.
Run Mode
Automatic mode
To run the Intimidator Free Spot 60 ILS in automatic mode, follow the
instructions below:
- Press
- Press
. - Use
or to select Auto. - Press
.
Sound-active mode
To run the Intimidator Free Spot 60 ILS in sound mode, do the following:
- Press
- Press
. - Use
or to select Sound. - Press
.
RF mode
To use the Intimidator Free Spot 60 ILS with an RFC or RFC-XL remote, it must
first be set to RF mode. To do this, follow the instructions below:
- Press
- Press
. - Use
or <DOWN?> to select RF. - Press
.
**** For more information about using the Intimidator Free Spot 60 ILS with an RF remote, see RFC Remote Control section.
Manual Mode
To operate the Intimidator Free Spot 60 ILS manually through the menu, do the
following:
- Press
- Press
. - Use
or to select Manual. - Press
. - Use
or <DOWN?> to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus, Dimmer, or Shutter. - Press
. - Use
or to increase or decrease the value of the selected function, from 000-255. - Press
. - Repeat steps 6-9 until the product is set as desired.
Settings Configuration
Use a DMX controller to set and control the Intimidator Free Spot 60 ILS.
D-Fi Settings
To access the D-Fi Setting menu on the Intimidator Free Spot 60 ILS, do the
following:
- Press
- Press
. - Use
or <DOWN?> to select DFI (to activate D-Fi mode) or DFI Channel (to set the D-Fi channel). - Press
.
To set which D-Fi mode the Intimidator Free Spot 60 ILS will follow, follow the instructions below:
- Select the DFI option.
- Use
or <DOWN?> to select RX (to set the product to receive D-Fi signal), TX (to set the product to transmit D-Fi signal), or OFF (to deactivate D-Fi mode). - Press
.
To set the D-Fi channel on the Intimidator Free Spot 60 ILS, do the following:
- Select the DFI Channel option.
- Use
or to set the D-Fi channel, from 1-16. - Press
.
Pan Reverse
To manually set the orientation of the pan on the Intimidator Free Spot 60
ILS, follow the instructions below:
- Press
- Press
. - Use
or to select Pan Reverse. - Press
. - Use
or to select OFF (normal pan motion) or ON (reversed pan motion). - Press
.
Tilt Reverse
To manually set the orientation of the tilt on the Intimidator Free Spot 60
ILS, do the following:
- Press
- Press
. - Use
or to select Tilt Reverse. - Press
. - Use
or to select OFF (normal tilt motion) or ON (reversed tilt motion). - Press
.
Screen Reverse
To manually set the orientation of the tilt on the Intimidator Free Spot 60
ILS, do the following:
- Press
- Press
. - Use
or to select Screen Reverse. - Press
. - Use
or to select OFF (normal screen display) or ON (reversed screen display). - Press
.
Pan Range
To set the maximum angle of the pan on the Intimidator Free Spot 60 ILS, do
the following:
- Press
- Press
. - Use
or to select Pan Range. - Press
. - Use
or <DOWN?> to set the pan angle from 180 (180°), 360 (360°), or up to 540 (540°). - Press
.
Tilt Range
To set the maximum angle of the tilt on the Intimidator Free Spot 60 ILS,
follow the instructions below:
- Press
- Press
. - Use
or to select Tilt Range. - Press
. - Use
or to set the tilt angle from 90 (90°), 180 (180°), or up to 234 (234°). - Press
.
Totem Mode
To restrict the range of pan and tilt motion based on how the Intimidator Free
Spot 60 ILS is mounted, do the following:
- Press
- Press
. - Use
or to select Totem Mode. - Press
. - Use
or <DOWN?> to select from OFF (no restriction on the pan and tilt motion), UP (restricts the pan and tilt motion for overhead mounting), or DOWN (restricts the pan and tilt motion for surface or floor mounting). - Press
.
Sound Sensitivity
To set the sound sensitivity on the Intimidator Free Spot 60 ILS, follow the
instructions below:
- Press
- Press
. - Use
or to select Sensitivity. - Press
. - Use
or <DOWN?> to increase or decrease the sound sensitivity, from 000—-100. - Press
.
DMX Loss
To set the action that the Intimidator Free Spot 60 ILS will do when the DMX
signal is lost, do the following:
- Press
- Press
. - Use
or to select DMX Loss. - Press
. - Use
or <DOWN?> to select from Hold (holds the last setting when DMX signal is lost), Black (blacks out the fixture when DMX signal is lost), Auto (sets the fixture to Auto mode when DMX signal is lost), or Sound (sets the fixture to Sound mode when DMX signal is lost). - Press
.
Indicator
To enable or disable the LED indicator on the Intimidator Free Spot 60 ILS,
follow the instructions below:
- Press
- Press
. - Use
or <DOWN?> to select Indicator. - Press
. - Use
or to select from ON (enables the LED indicator) or OFF (disables the LED indicator). - Press
.
Flash if DMX
To set whether the LED indicator flashes when the Intimidator Free Spot 60 ILS
is connected to or disconnected from the DMX, do the following:
- Press
- Press
. - Use
or <DOWN?> to select Flash if DMX. - Press
. - Use
or <DOWN?> to select from ON (the LED indicator flashes when the fixture is connected to the DMX) or OFF (the LED indicator flashes when the fixture is disconnected to the DMX). - Press
.
Run Time
To adjust the run time on the Intimidator Free Spot 60 ILS, follow the
instructions below:
- Press
- Press
. - Use
or <DOWN?> to select Runtime. - Press
. - Use
or to select the number of hours the fixture will run: 4 Hours, 6 Hours, or 8 Hours. - Press
.
**** The maximum output is inversely proportional to the run time: The brighter the output, the less run time available.
RF Setting
To set how the Intimidator Free Spot 60 ILS will receive RF signal and work
with RF remotes, do the following:
- Press
- Press
. - Use
or to select RF. - Press
. - Use
or <DOWN?> to select from the following: Common (to allow the fixture to respond to all RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception). - Press
.
RF Group
To select which group of fixtures the RF remote will control, follow the
instructions below:
- Press
- Press
. - Use
or to select RF Group. - Press
. - Use
or to select Group 1-4. - Press
.
Follow Spot
To enable control of the Intimidator Free Spot 60 ILS via ILS command, do the
following:
- Press
- Press
. - Use
or to select Follow Spot. - Press
. - Use
or <DOWN?> to select ON (enables Follow Spot mode) or OFF (disables Follow Spot mode). - Press
.
Product Reset
To reset individual or all functions on the Intimidator Free Spot 60 ILS upon
startup, do the following:
- Press
- Press
. - Use
or to select Reset. - Press
. - Use
or <DOWN?> to select YES (enables reset of all functions from startup) or NO (disables product reset from startup). - Press
.
Factory Reset
To reset the product to factory default settings, follow the instructions
below:
- Press
- Press
. - Use
or to select Factory Reset. - Press
. - Use
or <DOWN?> to select YES (enables factory reset) or NO (disables factory reset). - Press
.
Product Information
To view the product information, do the following:
- Press
- Press
. - Use
or to choose among: - Ver: displays the current software version of the fixture
- Running Mode: displays the current running mode
- DMX Address: displays the DMX address
- Temperature: displays the LED PCB temperature in °C
- DFI: displays the fixture’s D-Fi status
ILS Mode
ILS (Integrated Lighting System) provides 4 modes that synchronize with the
GigBAR MOVE+ILS: Modes 1 and 3 synchronize with side 1 of the GigBAR MOVE+ILS,
whereas modes 2 and 4 synchronize with side 2 of the GigBAR MOVE+ILS. When
linked, effects will sync with the most similar effect on the selected side
of the GigBAR MOVE+ILS: Kinta effects will sync with one of the kintas, moving
heads will sync with one of the moving heads, and wash effects will sync with
one of the pars. Laser effects will sync with the laser, and strobe effects
will sync with the strobe effects regardless of ILS mode.
This product will synchronize with the spot effect on the selected side of the
GigBAR MOVE+ILS, as well as the laser and strobes.
To set the Intimidator Free Spot 60 ILS to respond to an ILS signal:
- Press
- Use
or <DOWN?> to select from ILS1 (side 1), ILS2 (side 2), ILS3 (side 1), or ILS4 (side 2). - Press
.
Master/Slave Mode
The Master/Slave mode allows a single Intimidator Free Spot 60 ILS product
(the “master”) to control the actions of one or more Intimidator Free Spot 60
ILS products (the “slaves”) without the need of a DMX controller. The master
product will be set to operate in Standalone, whereas the slave products will
be set to operate in Slave mode. Once set and connected, the slave products
will operate in unison with the master product. Configure the products as
indicated below.
Slave products:
- Press
- Use
or to select DFI. Press . - Use
or to select RX. Press . - Press
- Use
or <DOWN?> to select Slave. Press . - Use
or <DOWN?> to select the slave unit(s), from Slave1—4. Press . - Set the DMX address to 001.
- Set the D-Fi to receive a specific channel, 1-16.
- Finish setting and connecting all the slave products.
Master product :
- Set the master product to operate in standalone mode.
- Set the D-Fi to transmit on the D-Fi channel the slaves are receiving on.
- For more information on how to activate the Intimidator Free Spot 60 ILS built-in D-Fi, see D-Fi Settings.
- All products must be set to the same DMX personality, DMX address, and D-Fi channel.
- Configure all the slave products before configuring the master to transmit.
- Never connect a DMX controller to a D-Fi channel configured for Master/Slave operation because the controller may interfere with the signals from the master.
RFC Remote Control
The Intimidator Free Spot 60 ILS can be operated with an RFC remote or an RFC-
XL remote (sold separately). To enable RF control, follow the instructions
below:
- Press
- Press
.\ - Use
or to select RF. - Press
. - Use
or to select from the following: Common (to allow the fixture to respond to all RF signals), Bind (to link the fixture to a single RF remote), or Off (to turn off RF reception). - Press
.
**** For more information about using an RFC or RFC-XL remote, download the user manuals from www.chauvetdj.com
RFC-XL Remote Control Operation
Automatic Mode
Automatic mode will enable you to run the automatic programs on the product.
To turn on Automatic mode:
1. Press
2. Press <+> or <> to choose between the different auto programs.
To adjust the speed of the automatic program:
- Press <SPEED/SENSITIVITY>.
- Press <+> or <> to increase or decrease the speed of the program.
Sound-Active Mode
To turn on Sound-Active mode:
- Press
. - Press <+> or <—> to select a sound-active program.
To adjust the sound sensitivity:
- Press <SPEED/SENSITIVITY>.
- Press <+> or <> to increase or decrease the sensitivity.
Dimmer
To adjust the total output of the product:
- Press
. - Press <+> or <> to increase or decrease the output level.
Prism
To adjust the focus of the product’s output:
- Press
. - Press <+> or <> to select the prism.
Focus
To adjust the focus of the product’s output:
- Press
. - Press <+> or <> to adjust the focus.
Pan
To adjust the product’s pan angle:
- Press
. - Press <+> or <> to adjust the pan.
Black Out
To black out the lights of the product:
- Press
. This will tum off all the lights until the button is pressed again.
**** The RFC-XL remote will not respond to any inputs when Black Out is
activated. If the remote does not respond when a button is pressed, try
pressing
Maintenance
Product Maintenance
Dust build-up reduces light output performance and can cause overheating. This
can lead to reduction of the light source’s life and/or mechanical wear. To
maintain optimum performance and minimize wear, clean all lighting products at
least twice a month. However, be aware that usage and environmental
conditions could be contributing factors to increase the cleaning frequency.
To clean the product, follow the instructions below:
- Unplug the product from power.
- Wait until the product is at room temperature.
- Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the external surface/vents.
- Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropyl alcohol.
- Apply the solution directly to a soft, lint-free cotton cloth or a lens-cleaning tissue.
- Softly drag any dirt or grime to the outside of the transparent surface.
- Gently polish the transparent surfaces until they are free of haze and lint.
Always dry the transparent surfaces carefully after cleaning them.
Technical Specifications
Dimensions and Weight
Length | Width | Height | Weight |
---|---|---|---|
114 in (290 mm) | 11.9in (301 mm) | 15.4in (391 mm) | 221b (9.9 kg) |
Note: Dimensions in inches rounded to the nearest hundredth.
Power
Power Supply Type | Range | Voltage Selection |
---|---|---|
Switching (internal) | 100 to 240 VAC, 50/60 Hz | Auto-ranging |
Parameter | 120 V, 60 Hz | 230V, 50 Hz |
Consumption | 1MOW | 107 W |
Operating Current | 0.9A | 0.5A |
Fuse | T2A,250V | T2A,250V |
Power /O | U.S./Worldwide | UK/Europe |
Power cord plug | Edison (U.S.) | Local plug |
Light Source
Type | Quantity | Color | Power | Current | Lifespan |
---|---|---|---|---|---|
LED | 1 | Cool white | 70W | 4.8A | 50,000 hours |
Photometrics
Strobe Rate| Zoom Range| llluminance @ 2 m (13°)|
llluminance @ 2 m (19°)
---|---|---|---
0to23Hz| 13°-19°| 16,932 lux| 9,424 lux
Thermal
Maximum External Temperature | Cooling System |
---|---|
104 °F (40 °C) | Convection |
DMX
Input/Output | Channel Range |
---|---|
3-pin XLR | 8,10, or 14 |
Ordering
Product Name | Item Code | UPC Number |
---|---|---|
Intimidator Free Spot 60 ILS | 10012030 | 7.81E+11 |
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
Address: 3360 Davie Rd.
Davie, FL 33314
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084| Voice:
844-393-7575
Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet Benelux
Address: Stokstraat 18
9770 Kruishoutem
Belgium
Voice: +32 9 388 93 97| Email:
BNLtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet France
Address: 3, Rue Ampére
91380 Chilly-Mazarin
France
Voice: +33 178 85 33 59| Email:
FRtech@chauvetlighting.fr
Website: www.chauvetprofessional.eu
Chauvet Germany
Address: Bruno-Biirgel-Str. 11
28759 Bremen
Germany
Voice: +49 421 62 60 20| Email:
DEtech@chauvetlighting.de
Website: www.chauvetprofessional.eu
Chauvet Mexico
Address: Av. de las Partidas 34 – 3B
(Entrance by Calle 2)
Zona Industrial Lerma
Lerma, Edo. de México, CP 52000
Voice: +52 728-690-2010| Email:
servicio@chauvet.com.mx
Website: www.chauvetprofessional.mx
Warranty & Returns
For warranty terms and conditions and return information, please visit our
website.
For customers in the United States and Mexico: www.chauvetlighting.com
/warranty-registration.
For customers in the United Kingdom, Republic of Ireland, Belgium, the
Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu
/warranty-registration.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>