Thank you for purchasing this light fitting. Please read the instructions
carefully before use to ensure safe and satisfactory operation of this
product. Please retain these instructions for future reference.
Warning
This light fitting is double insulated and does not require connection to an
earth circuit.
Please read these instructions carefully before commencing any work
This unit must be fitted by a competent and qualified electrician.
Install in accordance with the IEE Wiring regulations and current Building
Regulations.
Check the pack and make sure you have all the parts listed.
To prevent electrocution switch off at the mains supply before installing or
maintaining this fitting. Ensure other persons cannot restore the electrical
supply without your knowledge.
This light fitting should be connected to a circuit.
If replacing an existing fitting, make a careful note of the connections.
This product has no special protection against the ingress of moisture.
Always use the correct type and wattage bulb. Never exceed the wattage stated.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your local authority or
retailer for recycling advice.
Layout
Plan the desired layout of these fittings carefully, ensuring the cables will
reach the distances between the junction box and each light fitting.
Avoid locating any cables in positions that would cause a hazard.
The mains supply cable must have a minimum cross sectional area of 1.0mm.
Cables must be protected using suitable conduit or plastic trunking.
This product must be mounted out of arms reach.
The unit must be located a minimum distance of 100mm from a joist.
Spotlights give a concentrated beam of light and must not be positioned any
closer than 0.5m (50cm) to the illuminated surface.
This product is NOT suitable for direct mounting on normally flammable
surfaces (suitable only for mounting on non-combustible surfaces).
Luminaires not suitable for covering with thermally insulating material.
Installation
Existing fittings must be completely removed before installation of a new
product. Before removing the existing fitting, carefully note the position of
each set of wires.
Note that the switch is turned off before installation.
The ceiling surface must be flat and smooth to ensure a good fit.
Plan the desired layout of this fitting carefully, ensuring the cables will
reach the distance between the junction box and the light fitting.
- Cut a mounting hole Sq:175mm x 85mm diameter in the ceiling taking care not to foul any pipes, mains cables or joists beneath the surface. It is always recommended to cut the hole slightly smaller than the size specified, and then file the hole until the recessed unit fits snugly.
- Ensure a minimum ceiling void depth of 130mm is available.
- Ensure free movement of air by removing void insulation from at least 150mm from around the hole. Under no circumstances must these fittings be covered with insulating matting or similar material.
- Secure the product to the ceiling with the supplied screws.
- Follow the installation steps below to install.
- Please remove the PVC cover before using.
- Switch on. Your light is now ready for use.
Wiring
Unclip the cover from the quick fit connection case. Having correctly
identified the wiring from your existing light fitting, pull the mains wire
through the hole and connect to the quick fit connection block in the following
way. No tools are necessary.
Check that…
You have to correctly identified the wires.
The connections are tight.
No loose strands have been left out of the connection block.
The cover on the connection box has been replaced.
Fitting/replacing the bulbs
- When changing a bulb, always switch off at the mains and allow the bulb to cool before handling. Dispose of used bulbs carefully. Use a soft cloth to handle bulbs, avoid directly touching the bulbs as this will shorten their life. Do not exceed the wattage stated or use a different shape bulb from that indicated on the fitting. To replace the bulb, Rotate decorative bezel anti-clockwise.
- Drop down and slide bulb out from clip. To refit, slide bulb into clip, slide bulb into clip, and refit the decorative bezel.
Technical data
240 V~, 50 Hz Supply
Voltage: Bulb
Type: 2 x Max. 50W GU10 (required)
** Conformity with all relevant EC Directive requirements.
The power supply is Double Insulated and does not require connection to an
Earth circuit.
Waste electrical products should not be disposed of with household waste.
Please recycle where facilities exist. Check with your Local Authority or
local store for recycling advice.
This product is suitable for dimming.
Care and Safety**
We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive
cleaners as these could damage the finish.
For your safety, always switch off the power supply before cleaning.
Always disconnect the product from mains at least 10 minutes allowing to cool
down before any maintenance or adjustment.
V1 07/01/2021
Saxby Lighting. BH17 7BY
www.saxbylighting.com
Documents / Resources
|
saxby lighting 94754 Trimless Downlight
Twin
[pdf] Instruction Manual
94754, 94754 Trimless Downlight Twin, Trimless Downlight Twin, Downlight Twin,
Twin
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>