vetus EC4 High Quality Engine Remote Controls User Manual
Introduction
This manual describes the Trolling option for what is concerning operating instructions, programming, electrical installation and commissioning. For general information about how to install an electronic control system, please refer to the product manual for control levers EC3 & EC4. The same Trolling option can be used either with levers EC3 & EC4.
General installation features
Description of the system and its parts
The electronic system with the trolling option is composed of:
- Up to 3 command stations
- N° 1 Actuator including trolling option
- Data communication cables which connect the command stations to the Actuators
- T CANBus connectors
- Electrical cables towards motor, gearbox and trolling valves
Trolling option in combination with Flap option
In case in addition to the trolling option it is required also the Flap
option, the system must be added of the option kit which is composed of:
- Trim/Flap box
- N°1 data communication cable
- N°1 T CANBus connector
- Electrical cables towards Trim/Flap pump
Maximum extension of the system
The maximum configuration of the system is as shown in the following
table:
Actuators | The maximum number of engines that the system can control is 2 |
---|---|
Command stations | The maximum number of command stations in the installation |
is 3
80 meters| Maximum distance between cockpit and engine room
Pilot instructions
The command station for the standard electronic system or for the electronic system with the trolling option is the same. It is possible to switch between standard operating mode and trolling mode and vice versa by simply depressing for 2 seconds the Command push button of the station which at the moment has the command of the electronic system (red command light = “ON”). Entering and exiting trolling mode can only occur with command levers in one of the three detent positions: forward, neutral or backward.
Standard operating mode
If you press down another time the command push-button, trolling is
deactivated and the red LED displays a fixed red light and you are in standard
operating mode. In standard operating mode, moving the lever from the neutral
position, after 16° forward or reverse automatically the electronic system
clutches-in respectively the forward or reverse gear. The accelerator lever
has a stroke of 62° both in forward and backward direction for setting the
motor RPM.
Trolling mode
When trolling mode is active, the red LED flashes and the the behaviour of the
lever is the following:
- moving the lever from the neutral position, after 16° forward or reverse automatically the electronic system clutches-in respectively the forward or reverse gear
- forward and reverse position are easily recognizable by the mechanical detents. At these lever’s positions, gear is engaged with trolling working at 100%. With trolling = 100%, the boat should be standstill because no movement is transmitted to the propeller
- moving the lever from 16° to 48°, the trolling percentage progressively reduces and the propeller speed progressively increases
- when lever reaches 48°, trolling = 0%, the gear is completely engaged and the propeller rotates with motor at minimum speed
- from 48° to 80°, throttle speed increases from minimum to maximum (with gear completely engaged)
Lever functionality without trolling
Lever functionality with trolling enabled
To be noticed: at power on, trolling function is automatically active
Trolling mode can be passed from one command station to the other, exactly
like all the other system functions. If you acquire the command from another
station where trolling was already activated, the trolling will automatically
be enabled also on the station which has taken the command (inheritance of the
command).
Signals indicating that the system is in Trolling mode
When Trolling mode is activated the Command (red) LED is:
- fast blinking when at least one of the levers are in the trolling mode area
- slow blinking when both the levers are out of the trolling mode area. In this case trolling function will be activated as soon as one of the levers enters again into the trolling area.
- fixed light if trolling function is deactivated
Control keypad
On the command station it is mounted an electronic keypad with 4 push-buttons
and 4 LEDs.
Command station EC3 | Command station EC4 |
---|---|
without trim option | with trim option |
| |
Description| LEDs colour
---|---
Engine ()| Green
Warm/Sync| Orange
Command| Red
Engine ()| Green
In installations with single engine, both the green LEDs are referring to the same engine. In systems with 2 engines the push button and the green LED on the right are referring to the starboard engine while the push button and the green LED on the left side are referring to the port engine.
It follows the table with the definition of LED and push buttons.
Push-button | LED | Description |
---|---|---|
Engine | The left LED is for the port (left) engine, while the right LED is |
for the star- board (right) engine. If the LED has a fixed light on (green),
the correspond- ing gearbox is in neutral position.If a command station has
not the command, a blinking (green) LED indi- cates that the lever on the
LED’s side is synchronised with the lever of thestation that at the moment has
the Command.
| Command| If it is switched off, the Station has not the command. If is
switched on, the Station has the command.
| Warm/Sync| If it is blinking, the navigation system is in Warm-up mode; this
means that the engines can be accelerated without clutching-in the gear.If the
LED is fix lighted, the system is in Synchro mode.
Warm/Sync| | When both the levers of the Station that has the command are in
neutral position, if you press for 1,5 seconds the button Warm, it is
activated the function Warm-up.
Command| | If you press Command for 1,5 seconds the station takes the command,
only if one of these two conditions are respected:- both the lever of the
station are in neutral- both the lever are synchronized with respect to
the levers of the station that at the moment has the command
All LEDs are lighted on| The control system isn’t working correctly
Acquisition of the command
It is possible to acquire the command of the boat from any Station in the
following cases:
The boat isn’t moving
- Position both the levers in neutral and press Command for 1,5 seconds.
- LED “Command” is now lighted on while the warm/synch LED is blinking. You are in Warm-up mode: throttle command is enabled but clutch command is disabled.
- To take the command you must press for 1,5 seconds the Warm/Sync bush-button, afterwards the station acquires the command.
In navigation
- Synchronize the 2 levers of the Station which wants to acquire the command with respect to the Station which has the command.
- When LEDs “Engine” of the station which wants to acquire the command are blinking, these levers are synchronised with the levers of the station which still has the command.
- By pressing the pushbutton Command for 1,5 seconds, the new station takes the command.
Important: before taking the command, proof that all the passengers are safely on board.
Engine Warm-up
If both levers are in neutral, by pressing for 1,5 seconds the button
Warm/Sync of the Station which has the command, you enter in Warm-up mode. If
you move the lever, it is only affected the accelerator but not the gear. In
Warm-up mode the LED Warm/Sync is blinking. After positioning again both
levers in neutral and pressing for 1,5 seconds the Warm/Sync, the system comes
back to the normal operation mode.
Synchro mode
It is possible to command both engines at the same speed and direction with
only one lever. This function can be activated only by the station which has
the command. With both levers in neutral position, press at the same time for
1,5 seconds the two “engine” push buttons. The command of both engines is now
on the right lever. In Synchro operation mode, the LEDs “Warm/Sync” and
“Command” are lighted on. From “Synchro” operation mode, if you position both
levers in neutral, and press contemporaneously for 1,5 seconds the two
“Engine” push buttons, the command of each engine is again assigned to the
respective lever and LED “Warm/Sync” is switched off. The same operation of
synchronisation or de-synchronisation can be performed on the station which
has the command, in case the RPM between the two motors doesn’t differ more
than 10%.
Fast Start-up Mode
This function is available on the first command station as described in
section 8.1 of this manual. When the configuration FSM (Fast Start up Mode) is
enabled, the command station with the FSM enabled takes automatically the
command at the power on, only if this command station is in neutral position.
If the command station is not in neutral position, the command station will
take the command as soon the neutral position will be reached.
Command station
Under the base of the command station there is an aluminium cap. Unscrewing it, you can access to a 4 poles dip-switch and you can make various settings relevant to the command station behaviour, as depicted in the station’s adhesive stick. If you move switch 2 in ON position, the trolling function will be enabled.
Operations:
- unscrew the cap;
- set the dip-switch position according to the following table;
- screw again the cap
Dip-switch 1: | OFF | Line termination disabled |
---|---|---|
ON | Line termination enabled | |
Dip-switch 2: | OFF | Trolling disabled |
ON | Trolling enabled | |
Dip-switch 3 | Dip-switch 4 | |
--- | --- | --- |
Address 1 | OFF | OFF |
Address FSM | ON | OFF |
Address 2 | OFF | ON |
Address 3 | ON | ON |
DIP switch configuration
| 1| 2| 3| 4
1 st command station| | | |
1 st command station FSM| | | |
2 nd command station| | | |
3 rd command station| | | |
If trolling function is disabled by setting switch 2=OFF, trolling is not activable (on a command station that has the command, pressing the Command button will not produce any effect: its behaviour will be the one of a standard plant).
Actuator
The actuator for full electronic systems looks according to the below drawing.
Per each engine it is necessary:
- N° 1 cable for the throttle.
- N° 1 cable 6 poles for the gearbox + neutral relay (code ECG3/6,ECG5/6 or ECG7/6 (see product manual EC3-EC4))
- N° 1 cable 2 poles for the PWM command of the trolling (2 wire used, code EC3T3M (see product manual EC3-EC4))
Wiring from the actuator box to gearbox with trolling option
Cabling of gearbox and neutral relay
Function | Wire number |
---|---|
Forward (FWD) – Signal | 1 |
Reverse (REV) – Signal | 2 |
Neutral relay | 3 |
Forward (FWD) – GND | 4 |
Neutral relay | 5 |
Reverse (REV) – GND | 6 |
Cabling of the trolling valve
Function | Wire colour |
---|---|
Trolling PWM signal | Brown |
Trolling PWM – GND | Blue |
Relays PCB version 3.0 for electronic gearboxes with trolling option
Pin | Description |
---|---|
1 | VDC |
2 | GND |
3 | (Not connected) |
4 | GND (connect to Wire ID 4 and 6 of “Gearbox + neutral” connectors, both |
left and right)
5| Connect to VDC (Pin 1)
6| Forward Left (Wire ID 1, “Gearbox + neutral” connector)
7| Backward Left (Wire ID 2, “Gearbox + neutral” connector)
8| (Not connected)
9| Neutral relais – NC contact – Left(Wire ID 3, “Gearbox + neutral”
connector)
10| Neutral relais – COM – Left(Wire ID 5, “Gearbox + neutral” connector)
11| trolling Left (BROWN, “Trolling” connector)
12| trolling Left (GND, BLUE, “Trolling” connector)
13| (Not connected)
14| (Not connected)
15| trolling Right (BROWN, “Trolling” connector)
16| trolling Right (GND, BLUE, “Trolling” connector)
17| (Not connected)
18| (Not connected)
19| Neutral relais – COM – Right(Wire ID 5, “Gearbox + neutral” connector)
20| Neutral relais – NC contact – Right(Wire ID 3, “Gearbox + neutral”
connector)
21| Connect to VDC (Pin 1)
22| Forward Right (Wire ID 1, “Gearbox + neutral” connector)
23| Backward Right (Wire ID 2, “Gearbox + neutral” connector)
24| (Not connected)
Programming of the Trolling functions
This chapter is dedicated to the specific parameters for setting up the trolling functionalities: for general programming of the actuator please refer to chapter 11 of the Lever EC3 – EC4 Product Manual.
Trolling actuator parameters
Flexball actuator for trolling control permits to adapt to every trolling
valve system by correctly modifying a specific set of parameters, which are
listed in the following table.
Important note: don’t modify these parameter unless you have completely understood their meaning and the trolling valve system. Personal injury and mechanical/electrical damages may occur!
Parameter / display code| Min| Max| Def| Unit|
Description
---|---|---|---|---|---
P0/S0| 0| 99| 15| %| PWM % @ minimum trolling speed(P ->PORT (left), S ->
STARBOARD (right) engine)
P1/S1| 0| 99| 23| %| PWM % @ maximum trolling speed(P ->PORT (left), S ->
STARBOARD (right) engine)
t2| 0| 99| 0| %| PWM % during propeller start
t3| 0| 99| 2| s/10| propeller start’s time span
t4| 0| 99| 0| %| RPM Engine % increment (related to minimum engine speed)
reached @ maximum trolling speed
t5| 0| 1| 0| –| PWM% @ neutral position, either 0 or P0/S0
t6| 0| 99| 0| %| Reserved (not used)
t7
|
0
|
99
|
0
|
%
|
RPM Engine % increment (related to minimum engine speed) maintained after
trolling speed ramp
Parameter ““P0”/ “S0”
This parameter defines the PWM percentage applied to the trolling valve when
trolling is maximum (100%). It determines the minimum propeller speed. Default
value is 14%.
P0 is for LEFT engine, S0 for RIGHT engine.
Parameter “P1”/ “S1”
This parameter defines the PWM percentage applied to the trolling valve when
trolling is minimum (0%). It determines the maximum propeller speed at the end
of the trolling ramp. Default value is 21%.
P1 is for LEFT engine, S1 for RIGHT engine
Parameter “t2”
In order to reduce the time to start the boat, it might be necessary to give a
quick “kick-off”. Parameters “t2” and “t3” permit to apply a for a limited
time (t3) a higher speed on the propeller. “t2” defines the percentage to be
applied for a defined amount of time, before entering in trolling mode.
Parameter “t3”
It defines for how much time can be applied the “kick-off” before entering in
trolling mode.
Parameter “t4”
In some application it might be useful to slightly change the motor speed
during the trolling ramp. When motor is idling, motor speed could be at its
minimum. When the gear is engaged, it might be necessary to slightly increase
the motor RPM to compensate an increase of the increased load of the shft +
propeller, which are now clutched together with the motor. At the end of
trolling ramp engine will reach the value imposed with this parameter: during
trolling ramp the engine’s speed will vary proportionally from “native“
minimum speed to the one defines by parameter t4.
Important note: don’t exceed the maximum input speed for your trolling
valve system!
Check carefully its technical data and set t4 correctly!
Parameter “t5”
This parameter defines the current will flow through the trolling valve
command when trolling function is active but the gearbox is in neutral state.
If you leave it at 0, no current will flow in the trolling solenoid valve when
the gearbox is in neutral position. If you set it to 1, the current that flows
in neutral position is determined by S0/P0 parameter. On ZF gearboxes it is
recommended to set t5=0 (default condition).
Parameter “t6”
Reserved.
Parameter “t7”
When trolling is activated, this parameter defines the minimum engine’s RPM at
the end of trolling speed ramp. When trolling is activated, if you set t4
equal to t7 no discontinuity will occur passing through trolling ramp zone and
acceleration zone.
Important note: once you have set t7 > 0, minimum speed will be increased also when the system is working in no trolling mode!
The following pictures describe the trolling parameters effect in case trolling is active.
Notes:
- In the third graph, time “0” is the instant at which the lever reaches the mechanical indent (gear engagement): no more lever movement is assumed;
- “t0” stands for both “P0” and “S0” parameters, “t1” stands for “P1” and ”S1”.
Flap actuator box option
In case in addition to the trolling option it is required also the Flap option, the system must be added of the option kit which is composed of:
- Trim/Flap actuator box
- N°1 T CANBus connector
- N°1 data communication cable
- Electrical cables towards Trim/Flap pump
It follows here below a drawing of the installation kit:
The actuator for trim/flap option looks according to the below drawing:
Installation scheme:
For all the instruction related to this function, please refer to the Lever EC3 – EC4 product Manual.
Wire number | Function |
---|---|
Yellow/green | Supply (external) |
Black 1 | TRIM/FLAP + |
Black 2 | TRIM/FLAP – |
System types and installation schemes
The actual plant architecture is related to
- type and quantity of engines;
- type of gearboxes;
- number of command stations.
Actuators and command stations, which communicate together through the CANBus network, must be configured in relation to where they are connected to the CANBus network. In the following installation schemes you can find:
- components necessary to build an installation;
- configuration of actuators and command stations in relation of their position on the CANBus network.
The following installation types and schemes cover the most common application cases.
Installation with 2 mechanical actuators – solution A
This installation scheme is valid for systems with up to 3 command stations and 2 engines and gearboxes, full electronic
Installation with 2 mechanical actuators – solution B
This installation scheme is valid for systems with up to 3 command stations and 2 engines and gearboxes, full electronic
Electrical cables
Cable actuator – gearbox + neutral relais
For the connection towards the gearbox solenoid driven.
Length | Vetus code |
---|---|
L=3 m | ECG3/6 |
L=5 m | ECG5/6 |
L=7 m | ECG7/6 |
Important : this cable is without connector on gearbox side
Actuator – Trolling valve cable & Actuator box – Trim/flap cable
The same cable is used either to connect the Actuator to the Trolling valve
and the Flap actuator box to the flap option.
- for the connection towards the trolling valve, use only back 1 and black 2 wires.
- for the connection between the Flap actuator box and trim/flap, please refer to the manual for the EC3 – EC 4 control lever”product manual”.
Important: this cable is without connector on trolling valve side and on the flap/pump side