SPECIFICATIONS

  • Inputs Gold Plated RCA jacks with adjustable gain
  • Input impedance 50k Ohms
  • Outputs 5 way gold plated binding posts
  • RMS Continuous 50 Watts (40 Watts per channel 20Hz to 20kHz
  • output power @ <0.2% THD all channels driven into 8 ohms)
  • Recommended speaker impedance 6 – 8 Ohms nominal
  • Frequency response 10 Hz – 40 kHz +/- 1dB (1W)
  • S/N ratio over 105 dB A-weighted (50 Watts)
  • THD distortion less than 0.1% 20 Hz to 20 kHz
  • IMD distortion less than 0.01% 60 Hz 7 kHz 4:1 (SMPTE)
  • Trigger control 12 VDC 35mA on 3.5mm mono jack
  • Dimensions 17″ x 3.5″ x 11.5″ (432 x 89 x 292mm)
  • Fan Noise quiet 28 dBA
  • Power 750 Watts at 117 VAC or 230VAC
  • Weight 22 lbs (10 kg)

NOTES: Inputs use RCA connectors Outputs use speaker binding posts

FEATURES

  • Automatic protection circuitry – Each amplifier channel is individually and fully protected against low impedance, overheating, overloading, over-voltage, and under voltage. The protection circuitry automatically restores the sound once the affected amplifier channel returns to the safe operating area.

  • Individual input gain adjustment – Each channel features an input gain adjustment to adjust the channel for volume, gain, and speaker sensitivity variations.

  • External power on/off – The amplifier can be turned off and on by external controllers. To activate external power “on”, apply a 12VDC current to the trigger jack using a compatible power supply. As long as the 12VDC is applied, the amplifier will remain on. The amplifier power switch should be in the “off” position for external power control.

  • Link Feature – The Link button is normally set to the “in” position to give all six stereo inputs individual sources. When the Link button is set to the
    “out” position, that input Left/Right is internally linked or cascaded to the source connected to input #1. Any of the five inputs (2 through 6) can be linked individually in any combination with the #1 input. When all inputs are linked to input #1 the input impedance is about 8500 Ohms.
    NOTE: When linked, unused RCA inputs can be used as outputs to other amplifiers.

  • Cooling fan – The AE6MA features a thermostatically controlled internal fan to help to avoid overheating and keep all channels within the safe operating area so that the likelihood of the protection circuitry being activated is reduced. The fan also helps maximize energy efficiency.

INSTALLATION

  • WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
  • WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
  • CAUTION: Never listen to a sound that is distorted. If distorted sound is heard, turn the volume down immediately or speaker and/or amplifier damage could occur that is not covered by the warranty.
  • CAUTION: The AE6MA contains no user-serviceable parts. Do not attempt to open or repair the AE6MA.

User Adjustments and Service: There are no user adjustments on the AE6MA. Your installer may make certain gain-level adjustments on the rear panel.

  1. The most important consideration when installing the AE6MA is cooling, since the amplifier packs a lot of audio power into a small-sized chassis. When installing the amplifier in an equipment stack, it should be the top component. Make sure to leave at least 3-5 inches (76.19mm-127mm) of space above the amplifier to allow for adequate cooling.
  2. Never operate the AE6MA on its side, as it will impair the unit’s cooling and void the warranty.
  3. Connect the AE6MA RCA inputs to the source component outputs using good-quality RCA cables. Connect each channel individually, unless using the Link feature.
  4. Connect the AE6MA speaker outputs to speakers using good quality speaker wire. It is recommended that 18 AWG speaker wires be used for runs up to 50 feet (15 m). For runs from 50-150 feet (15-45 m), 16AWG speaker wire should be used. And for runs over 150 feet (45 m), 14 AWG speaker wires should be used. Make sure the wire used is correctly rated for installation inside walls, ceilings, or floors. Check local codes for complete information.
  5. Impedance ratings (speakers): the AE6MA amplifier is designed to operate speakers with nominal impedance ratings between 6-8 Ohms. Connecting the amplifier to a speaker with a rating below 6 Ohms may result in the protection circuitry being activated and the channel being shut down. The amplifier should never be connected to a speaker rated at above 8 Ohms or below 4 Ohms. Failure to observe this could potentially cause damage to the amplifier.
  6. Individually adjust the channel gains as required. Ideally, all gains are fully on (fully clockwise).
  7. Make sure the speakers in each room are connected in-phase with the amplifier, i.e. the speaker wire from amplifier + going to the speaker +. NOTE: If the speakers are connected out-of-phase it will usually result in poor stereo imaging and bass response.
  8. The AE6MA is equipped with a trigger port that allows it to be remotely turned on and off. The power supply for the trigger port to function needs to be 12VDC 35mA minimum, with a 3.5mm plug. 5VDC triggers will not work.
  9. Connect the AC power into an outlet that can supply at least 6 amps (750 watts) dedicated to the AE6MA.

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.Leviton.com

TROUBLESHOOTING

If a problem is encountered with the AE6MA amplifier, the most expedient procedure is to locate the problem and if possible repair it before requesting service. Be sure to carefully check other system components such as controllers, CD players, volume controls, wiring, speakers, etc. that may be at fault.

Power led does not light – no sound

  • Check that the AE6MA amplifier is plugged in.
  • Test the AC outlet with a lamp.
  • If remote on/off is used, check that the trigger voltage is at 12VDC.
  • Check to see if the AE6MA power button is on (in).

Sound cuts out

  • Verify speaker impedance is 4-16 ohms. Changing speakers may be required.
  • Check if the amp feels hot. If it’s hot, increase cooling – see Installation note #1.

Sound is distorted

  • Turn the volume down.
  • Check speakers for damage.
  • Check inputs for proper levels. AE6MA amplifier gain and source output level may have to be adjusted.
  • Speakers may be less than 4 ohms.

AE6MA does not turn off

  • Turn AE6MA power switch off (out).
  • If trigger is being used, power switch needs to be set to off (out) position, or the amplifier is on all the time.
  • Try disconnecting trigger jack.

Trigger does not work

  • Measure trigger voltage with a volt meter. It needs to be 11-15 volts DC to work (current is 35mA per AE6MA) – see Installation note #8.

Speaker pops when amp turned on or off

  • Speaker may need resistor placed across terminal. Suggest 1/4 w 2k Ohm. This resistor discharges the speakers internal capacitor.

SAFETY INFORMATION

  • Use a 120-volt AC current with this unit. Using any other line voltage may create a safety and fire hazard and may cause damage to the unit. For questions concerning voltage requirements, contact a qualified electrician.
  • Use only the power cord attached to the unit. To prevent safety hazards, do not use extension cords. Replace damaged power cords immediately through an authorized service center.
  • Do not open the cabinet. This unit contains no user serviceable parts. Any modification to the unit will void the warranty. If any foreign object such as water or a paper clip falls into the unit, unplug the unit and consult an authorized service center.
  • Place the unit on a firm, level surface that can support the weight of the unit. This will ensure proper operation and avoid potential safety hazards.
  • Make sure to provide ventilation space above and below the unit, whether installed inside or outside of a cabinet or other enclosed area. A fan may be required under some circumstances.
  • Do not place the unit directly on a carpeted surface.
  • Avoid unit placement in extreme hot or cold locations, or in an area exposed to direct sunlight or heating equipment.
  • Avoid moist or humid locations.
  • Do not obstruct the ventilation slots on top of the unit.
  • To clean the unit, wipe with clean, soft, dry cloth. A soft cloth dampened with mild soapy water, and then a fresh cloth with water may be used, if necessary. Wipe dry immediately with a dry cloth. NEVER use a cleaning agent besides mild soap.
  • Before moving the unit, make sure to disconnect all interconnection cords to other components, and the AC outlet connection.
  • The carton and shipping materials used to protect the unit during shipment are designed to cushion it from shock and vibration. It is suggested that you save the carton and packaging materials to ship or move the unit in the future.

FREQUENTLY ASKED QUESTIONS

What is the Leviton AE6MA Architectural Edition 12-Channel Amplifier?

The Leviton AE6MA Architectural Edition 12-Channel Amplifier is a multi- channel audio amplifier designed for use in home theater and multi-room audio setups.

How many channels does the AE6MA amplifier have?

It has 12 channels, allowing you to power multiple audio zones or speakers.

What is the power output per channel?

The power output per channel may vary, so it's important to consult the amplifier's specifications for the exact power ratings.

What types of audio inputs does the amplifier support?

The amplifier may support a variety of audio inputs, such as RCA, XLR, or optical inputs, depending on its design.

Is the amplifier suitable for both residential and commercial use?

Yes, the Leviton AE6MA Architectural Edition amplifier is designed for both residential and commercial audio applications.

Does it support zone-specific volume control?

Yes, many multi-channel amplifiers like the AE6MA allow for individual volume control for each audio zone.

Is the amplifier rack-mountable?

Yes, some models of the AE6MA amplifier are rack-mountable, which is convenient for professional installations.

What is the amplifier's frequency response range?

The frequency response range can vary, but it typically falls within the range of 20Hz to 20kHz.

Can the amplifier be integrated with home automation systems?

Yes, some versions of the AE6MA amplifier may offer integration options with home automation systems, allowing for centralized control.

Does the AE6MA amplifier have built-in protection features?

Yes, many modern amplifiers include protection features such as overcurrent, overheat, and short-circuit protection.

What is the cooling mechanism for the amplifier?

The amplifier might use various cooling mechanisms, including fans or heatsinks, to prevent overheating.

Can the amplifier handle low-impedance and high-impedance speakers?

The amplifier's compatibility with different speaker impedance levels would be outlined in its specifications.

Is the AE6MA amplifier energy-efficient?

Energy efficiency can vary among different models, so it's advisable to check the specifications for energy consumption details.

Are there any EQ (equalization) settings on the amplifier?

Some amplifiers might include basic EQ settings for fine-tuning the sound output.

Is the AE6MA amplifier part of a larger audio system ecosystem?

Leviton might offer other audio products that can be integrated with the AE6MA amplifier for a complete audio solution.

VIDEO – PRODUCT OVERVIEW

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals