DELL Technologies S6000-ON 32-Port 40GbE QSFP Switch User Guide

June 12, 2024
DELL Technologies

Dell Technologies

Rev. A00
November 2021

Dell System S6000–ON 9.14(2.11) Release Notes

This document contains information on open and resolved caveats, and operational information specific to the Dell Networking OS software and the S6000-ON platform.
Current Release Version: 9.14(2.11)
Release Date: 2021-11-25
Previous Release Version: 9.14(2.10)

This document may contain language that is not consistent with current guidelines of Dell Technologies. There are plans to update this document over subsequent releases to revise the language accordingly.

Incorrect behavior or unexpected caveats are listed as the Problem Report (PR) numbers within the appropriate sections.

For more information on hardware and software features, commands, and capabilities, see the Dell EMC Networking website at: https://www.dellemc.com/networking.

Document Revision History

Table 1. Revision History

Date Description
2021­-11 Initial release.

Supported Hardware

The following hardware is supported with this platform:

Hardware

S6000-ON chassis
Thirty-two QSFP+ ports (40 Gbps)
Two AC/DC PSUs
Three fan subsystems

If all the three fan trays are found to be empty or faulty, the system shuts down after one minute.

Supported Software

The following software is supported with this platform:

Software Minimum Release Requirement
Dell Networking OS 9.14(2.11)
BigSwitch 4.0.0
Cumulus: S6000-ON (S6000 with ONIE) Cumulus Linux 2.1
ONIE v3.20.1.3
New Dell Networking OS Version 9.14(2.11) Features

The following features are integrated into the Dell Networking 9.14.2 branch through this release:
None

Restrictions

  • Prerequisite steps to upgrade the Dell Networking OS from earlier version to 9.14.2.0 or later:

1. Uninstall the older version of the Open Automation (OA) package
2. Upgrade the Dell Networking OS to 9.14.2.0 or later version
3. Install the following OA packages from the respective upgraded version:

a. SmartScripts
b. Puppet
c. Open management infrastructure (OMI)
d. SNMP MIB

Prerequisite steps to downgrade the Dell Networking OS from 9.14.2.0 or later to the earlier version:

1. Uninstall the OA package of 9.14.2.0 or later version
2. Downgrade the Dell Networking OS to an earlier version
3. Install the respective OA package from an earlier version

For more information about installing, uninstalling and upgrading the Dell Networking OS and OA package, see the respective Dell System Release Notes.

  • If you downgrade the Dell Networking OS version from 9.14.2.11 to 9.11.0.0 or any older versions, the system displays the following error message even though there is no functional impact:

CDB boot error:  C.cdb file format

Before downgrading, save the current configuration and then remove the CDB files (confd_cdb.tar.gz.version and confd_cdb.tar.gz). To remove the files, use the following steps:

Dell#write memory
Dell#delete flash://confd_cdb.tar.gz.version
Dell#delete flash://confd_cdb.tar.gz
Dell#reload

  • In a VXLAN scenario, hybrid port is not supported.
  • While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command at the beginning of the startup configuration if the write memory command is used at the end of the configuration.
  • When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
  • The following features are not available in the Dell Networking OS from version 9.7(0.0):
    • PIM ECMP
    • Static IGMP join (ip igmp static-group)
    • IGMP querier timeout configuration (ip igmp querier-timeout)
    • IGMP group join limit (ip igmp group join-limit)
  • You can use the negotiation auto command to turn auto-negotiation on or off only on fiber interfaces operating at 1G speed.
  • When 1024 or more VNI profiles are configured, the system takes more time to load. Dell recommends to restrict the VNI profiles to be less than 1000.
  • If you use the interface range command to select multiple interfaces that are added to the management VRF, the ipv6 address command does not display the autoconfig option. You can configure the autoconfig command on individual interfaces.
  • If you use the interface range command to select multiple interfaces that are added to the management VRF, the ipv6 nd command displays the following options but they do not take effect if you use them:
    • dns-server
    • hop-limit
    • managed-config-flag
    • max-ra-interval
    • mtu
    • other-config-flag
    • prefix
    • ra-guard
    • ra-lifetime
    • reachable-time
    • retrans-timer
    • suppress-ra
  • You cannot use the established keyword in an ACL rule, along with the other control flags.
  • While using the established keyword in an ACL rule, all the other TCP control flags are masked, to avoid redundant TCP control flags configuration in a single rule. When you use any TCP control flag in an ACL rule, established is masked and other control flags are available.

Changes to Default Behavior and CLI Syntax

  • If you are upgrading from an earlier OS9 version to 9.14.2.x, ensure you first upgrade to version 9.13.0.0 before upgrading to the required version of 9.14.2.x to prevent any issues during the upgrade procedure.

Upgrading the CPLD

The S6000-ON system with Dell Networking OS Version 9.14(2.11) requires System CPLD revision 10, Master CPLD revision 12, and Slave CPLD revision 10.

Verify that a CPLD upgrade is required

If your CPLD revisions are higher than the ones shown here, DO NOT make any changes. If you have questions regarding the CPLD revision, contact technical support.

Use the following command to identify the CPLD version:

Dell#show revision

—  Stack unit 0  —
S6000 SYSTEM CPLD     : 10

S6000 MASTER CPLD    : 12

S6000 SLAVE CPLD        : 10

Use the following command to view CPLD version that is associated with the Dell Networking OS image:

Dell#show os-version

RELEASE IMAGE INFORMATION :
———————————————————————
Platform       Version         Size               ReleaseTime
S-Series:SI   9.14(2.11)   62072761   Oct 18 2021  09:48:25

TARGET IMAGE INFORMATION :
———————————————————————
Type            Version                        Target     checksum
runtime     9.14(2.11)      Control Processor       passed

BOOT IMAGE INFORMATION :
———————————————————————
Type             Version                       Target    checksum
boot flash     3.1.1.7      Control Processor        passed

BOOTSEL IMAGE INFORMATION :
———————————————————————
Type                Version                      Target    checksum
boot selector    3.1.0.3     Control Processor        passed

FPGA IMAGE INFORMATION :
———————————————————————
Card                               FPGA Name            Version
stack-unit 0     S6000 SYSTEM CPLD                   10
stack-unit 0     S6000 MASTER CPLD                  12
stack-unit 0        S6000 SLAVE CPLD                   10

Installing Dell Networking OS on the S6000-ON using ONIE

The Dell Networking OS installer package, ONIE-FTOS-SI-ON-9.14.2.11.bin, is required for installing Dell Networking OS on S6000-ON that has only ONIE.

To upgrade the ONIE package you have installed, use one of the following two processes: zero touch (dynamic) update or manual update.

1. Zero touch (dynamic): Copy the update ONIE installer and the DIAG installer for your system to the TFTP/HTTP server.Configure the DHCP options using the ONIE specifications shown at the following link: http://opencomputeproject.github.io/onie/docs/design-spec/updater.html

S6000-ON image >>>> onie-updater-x86_64-dell_s6000_s1220-r0

2. Manual: Copy the image onto the TFTP/HTTP servers and boot ONIE. Update the ONIE using the onie-self-update command, then download and run an ONIE updater image. The supported URL types are: HTTP, FTP, TFTP, and FILE.

S6000-ON image >>>> onie-updater-x86_64-dell_s6000_s1220-r0

3. UPGRADING ONIE ON AN EXISTING S6000–ON SYSTEM.The following example uses TFTP to upgrade ONIE.

ONIE:/ # onie-self-update tftp:tftp server IP address/ONIE installer image path
ONIE:/ # onie-self-update tftp://10.11.227.233/onie-updater- x86_64-dell_s6000_s1220-r0
Info: Fetching tftp://10.11.227.233/onie-updater-x86_64-dell_s6000_s1220-r0 …
onie-updater-x86_64- 100% |***| 8541k 0:00:00
ETA
ONIE: Executing installer: tftp://10.11.227.233/onie-updater- x86_64-dell_s6000_s1220-r0


Reboot.

The following example uses HTTP to upgrade ONIE.

ONIE:/ # onie-nos-install http:http server IP address/ONIE installer image path
ONIE:/ # onie-nos-install http://10.11.227.233/dell/onie/S6000-ON/image- drop-18102021/
diag-in[Jstaller-x86_64-dell_s6000_s1220-r0.bin
***** Mon Oct 18 14:53:08 PDT 2021 **

Stopping: discover… done.
Info: Fetching http://10.11.227.223/dell/onie/S6000-ON/image- drop-18102021/diag-
installer-x86_64-dell_s6000_s1220-r0.bin …
Connecting to 10.11.227.233 (10.11.56.31:80)
installer 33% |** | 1730k 0:00:01
ETAinstaller 100% |***| 5091k
0:00:00 ETA
ONIE: Executing installer: http://10.11.227.233/dell/onie/S6000-ON/image-
drop-18102021/diag-installer-x86_64-dell_s6000_s1220-r0.bin
Ignoring Verifying image checksum … OK.
Preparing image archive …sed -e ‘1,/^exit_marker$/d’ /installer | tar xf – OK.
Diag Installer: platform: x86_64-dell_s6000_s1220-r0
Total Partitions are 2
false
Creating new diag partition /dev/sda3 …
Warning: The kernel is still using the old partition table.
The new table will be used at the next reboot.
The operation has completed successfully.

The system is going down NOW!.
Sent SIGTERM to all processes
Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart

4. Upgrade the DIAG installer package.

ONIE:/ # onie-nos-install tftp or http:IP address and path
014/diag-in[Jstaller-x86_64-dell_s6000_s1220-r0.bin
* Mon Oct 18 14:53:08 PDT 2021 **
Stopping: discover… done.
Info: Fetching http://10.11.56.31/dell/onie/S6000-ON/image-drop-18102021/diag-
installer-x86_64-dell_s6000_s1220-r0.bin …
Connecting to 10.11.56.31 (10.11.56.31:80)
installer 33% |** | 1730k 0:00:01
ETAinstaller 100% |***
| 5091k
0:00:00 ETA
ONIE: Executing installer: http://10.11.56.31/dell/onie/S6000-ON/image- drop-18102021/
diag-installer-x86_64-dell_s6000_s1220-r0.bin
Ignoring Verifying image checksum … OK.
Preparing image archive …sed -e ‘1,/^exit_marker$/d’ /installer | tar xf – OK.
Diag Installer: platform: x86_64-dell_s6000_s1220-r0
Total Partitions are 2
false
Creating new diag partition /dev/sda3 …
Warning: The kernel is still using the old partition table.
The new table will be used at the next reboot.
The operation has completed successfully.
.
.
.
The system is going down NOW!
Sent SIGTERM to all processes
Sent SIGKILL tosd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart

5. Upgrade the BIOS image using the BIOS image and Flashrom utility included with the diagnostic package.

ONIE:/ # flashrom -E -p internal

flashrom v0.9.10-r1711 on Linux 3.2.35-onie+ (x86_64)
flashrom is free software, get the source code at http://www.flashrom.org

Calibrating delay loop… OK.
Found chipset “Intel CentertonLPC”. Enabling flash write… OK.
Found Macronix flash chip “MX25L12805(D)” (16384 kB, SPI) at physical address
0xff000000.
Erasing and writing flash chip… Erase/write done.
ONIE:/ #

ONIE:/ # flashrom -w /tmp/diag/S6000-ON-BIOS-3.20.0.3.bin -p internal

flashrom v0.9.10-r1711 on Linux 3.2.35-onie+ (x86_64)
flashrom is free software, get the source code at http://www.flashrom.org

Calibrating delay loop… OK.
Found chipset “Intel CentertonLPC”. Enabling flash write… OK.
Found Macronix flash chip “MX25L12805(D)” (16384 kB, SPI) at physical address
0xff000000.
Reading old flash chip contents… done.
Erasing and writing flash chip… Erase/write done.
Verifying flash… VERIFIED.
ONIE:/ #
.
.
.
.
auto reboot

S6000–ON Upgrade Procedures: Overview

To upgrade the Dell Networking OS to the latest version, complete these steps:

When upgrading from an earlier version of OS9 (example: 9.10.0.1) to 9.14.2.x, first upgrade to 9.13.0.0 to prevent any issues during the upgrade procedure.

  • Upgrade the S6000–ON Dell Networking OS Image and Boot Code
  • Upgrading the CPLD
  • VLT Upgrade Procedure
Upgrade the S6000-ON Dell Networking OS Image and Boot Code using Dell

Networking OS CLI

Bare Metal Provisioning

If you are using Bare Metal Provisioning (BMP), see the Bare Metal Provisioning topic in the Dell Networking OS Configuration Guide or the Open Automation Guide.

Manual Upgrade Procedure

Follow these steps carefully to upgrade your S6000-ON systems:

1. Dell Networking recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.

2. Upgrade the Dell Networking OS in flash partition A: or B:

EXEC Privilege Mode

upgrade system [flash: | ftp: | stack-unit <1-6 | all> | tftp: | scp: | usbflash:] [A: | B:]

Dell#upgrade system tftp: A:
Address or name of remote host []: 10.16.127.35
Source file name []: S6K_on
02:08:59 : Discarded 1 pkts. Expected block num : 51. Received block num: 50
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………………………………..
…………………………………………………!
63287484 bytes successfully copied
System image upgrade completed successfully.
Dell#Oct 18 14:21:21: %STKUNIT1-M:CP %DOWNLOAD-6-UPGRADE: Upgrade completed successfully

3. In case of a stack setup, upgrade the Dell Networking OS for the stacked units.

EXEC Privilege Mode

upgrade system stack-unit [0-11 | all] [A: | B:]

If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed to the stack units. If B: is specified in the command, the Management unit’s B: will be pushed to the stack units. Upgrade of stack units can be done on individual units by specifying the unit id [1-6] or on all units by using all in the command.

Dell#upgrade system stack-unit all A:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Image upgraded to all
Dell#

4. Verify that the Dell Networking OS has been upgraded correctly in the upgraded flash partition.

EXEC Privilege Mode

show boot system stack-unit [1-6 | all]

Dell#show boot system stack-unit all

Current system image information in the system:

Type                  Boot Type             A                   B
———————————————————
stack-unit 1  FLASH BOOT    9.14(2.11)    9.14(2.10)[boot] stack-unit 2 is not present.
stack-unit 3 is not present.
stack-unit 4 is not present.
stack-unit 5 is not present.
stack-unit 6 is not present.
Dell#

5. Upgrade the S6000-ON Boot Flash and Boot Selector images

EXEC Privilege Mode

upgrade boot [all | bootflash-image | bootselector-image] stack-unit [1-6 | all] [booted | flash: | ftp: | scp: | tftp: | usbflash:]

Dell Networking OS version 9.14(2.11) requires S6000-ON Boot Flash image version 3.20.2.5 and Boot Selector image version 3.20.0.3. The Boot Flash and Boot Selector images can be upgraded together by selecting all in the command. If the user wants to upgrade Boot Flash image or Boot Selector image separately, the options bootflash-image or bootselector-image needs to be given separately in the command. The booted option is used to upgrade the Boot flash and Boot Selector images to the image versions packed with the loaded Dell Networking OS image. The Boot Flash and Boot Selector image versions packed with the loaded Dell Networking OS can be found using the show os- version command in EXEC PRIVILEGE mode. Dell #upgrade boot all stack-unit 1 booted

Dell# show os-version
RELEASE IMAGE INFORMATION :
———————————————————————
Platform                Version        Size               ReleaseTime
S-Series:SI-ON   9.14(2.11)   63304169   Oct 18 2021 09:47:31

TARGET IMAGE INFORMATION :
———————————————————————
Type              Version                         Target    checksum
runtime      9.14(2.11)      Control Processor        passed

BOOT IMAGE INFORMATION :
———————————————————————
Type               Version                       Target    checksum
boot flash      3.20.2.5      Control Processor        passed

BOOTSEL IMAGE INFORMATION :
———————————————————————
Type                 Version                       Target    checksum
boot selector    3.20.0.3     Control Processor        passed

FPGA IMAGE INFORMATION :
———————————————————————
Card                                      FPGA Name       Version
stack-unit 1     S6000-ON SYSTEM CPLD              10
stack-unit 1     S6000-ON MASTER CPLD             12
stack-unit 1        S6000-ON SLAVE CPLD              10
Dell#

Dell#upgrade boot bootflash-image stack-unit 1 ftp:
Address or name of remote host []: 10.16.127.35
Destination file name []: FTOS-SI-ON-9.14.2.11.bin
User name to login remote host: ftpuser
Password to login remote host:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Current Boot information in the system:

Card       BootFlash     Current Version     New Version
——————————————————————–
Unit1     Boot Flash                 3.20.2.5             3.20.2.5


  Warning – Upgrading boot flash is inherently risky and should only           
  be attempted when necessary. A failure at this upgrade may cause             
  a board RMA. Proceed with caution !                                                         


Proceed upgrade Boot Flash image for stack-unit 1 [yes/no]: yes

!!!!!!
Bootflash image upgrade for stack-unit 1 completed successfully.
Dell#
Dell#upgrade boot bootselector-image stack-unit 1 ftp:
Address or name of remote host []: 10.16.127.35
Destination file name []: FTOS-SI-ON-9.14.2.11.bin
User name to login remote host: ftpuser
Password to login remote host:
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

Current Boot information in the system:

=======================================================================
Card     BootSelector     Current Version      New Version
———————————————————————–
Unit1    Boot Selector                3.20.0.3               3.20.0.3


  Warning – Upgrading boot selectors is inherently risky and should             
  only be attempted when necessary. A failure at this upgrade may               
  cause a board RMA. Proceed with caution !                                               


Proceed upgrade Boot Selector image for stack-unit 1 [yes/no]: yes

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
Bootselector image upgrade for stack-unit 1 completed successfully.

6. Change the Primary Boot Parameter of the S6000-ON to the upgraded partition A: or B:

CONFIGURATION Mode

boot system stack-unit [1–6 | all] primary system: [A: | B: | tftp: | ftp:]

7. Save the configuration so that the configuration will be retained after a reload using write memory command.

EXEC Privilege Mode

write memory

Dell#write memory
!
Oct 18 18:58:59: %STKUNIT1-M:CP %FILEMGR-5-FILESAVED: Copied running-config to startup-config in flash by default

Dell#

8. Reload the unit.

EXEC Privilege Mode

reload

Command    : reload
Mode           : EXEC PRIVILEGE
Dell#reload
Proceed with reload [confirm yes/no]: y

9. Verify that the ONIE has been upgraded to the Dell Networking OS version 9.14(2.11).

EXEC Privilege Mode

show version

Dell#show version
Dell Real Time Operating System Software
Dell Operating System Version: 2.0
Dell Application Software Version: 9.14(2.11)
Copyright (c) 1999-2021 by Dell Inc. All Rights Reserved.
Build Time: Mon Oct 18 09:28:18 2021
Build Path: /build/build03/SW/SRC
Dell Networking OS uptime is 1 minute(s)

System image file is “system://B”

System Type: S6000-ON
Control Processor: Intel Centerton with 3 Gbytes (3203911680 bytes) of memory, core(s) 2.

16G bytes of boot flash memory.

1 32-port TE/FG (SI-ON)
32 Forty GigabitEthernet/IEEE 802.3 interface(s)
Dell#

10. Verify that the S6000–ON has been upgraded to the latest Boot Flash and Boot Selector images.

EXEC Privilege Mode

show system stack-unit [1-6]

Dell#show system stack-unit 1

— Unit 1 —
Unit Type                               : Management Unit
Status                                     : online
Next Boot                              : online
Required Type                        : S6000-ON – 32-port TE/FG (SI-ON)
Current Type                          : S6000-ON – 32-port TE/FG (SI-ON)
Master priority                        : 14
Hardware Rev                         : 4.0
Num Ports                              : 128
Up Time                                 : 1 min, 2 sec
Dell Networking OS Version  : 9.14(2.11)
Jumbo Capable                       : yes
POE Capable                         : no
FIPS Mode                             : disabled
Boot Flash                              : 3.20.2.5
Boot Selector                          : 3.20.0.3
Memory Size                          : 3203911680 bytes
Temperature                           : 33C
Voltage                                   : ok
Serial Number                        : NA
Part Number                          : Rev
Vendor Id                              : DL
Date Code                             : 10182021
Country Code                       : CN
Piece Part ID                        : CN-08YWFG-28298-3AG-0009
PPID Revision                      : N/A
Service Tag                            : N/A
Expr Svc Code                      : 0
Auto Reboot                         : enabled
Burned In MAC                    : 1a:ba:2a:b8:2d:9d
No Of MACs                        : 3

— Power Supplies —
Unit   Bay    Status    Type               FanStatus    FanSpeed(rpm)
————————————————————
2         1      up         AC                   up               6720
2         2      down    UNKNOWN   down          0

— Fan Status —
Unit   Bay     TrayStatus      Fan1    Speed    Fan2    Speed
—————————————————-
2         1        up                  up         7021      up       6922
2         2        up                  up         6971      up       7072
2         3        up                  up         7021       up      6971

Speed in RPM
Dell#

Upgrading the CPLD

The S6000-ON system with Dell Networking OS Version 9.14(2.11) requires System CPLD revision 10, Master CPLD revision 12, and Slave CPLD revision 10.

For the Port LEDs to work properly with the Dell Networking OS version 9.9(0.0P5), downgrade the CPLD version to 12.

Verify that a CPLD upgrade is required

Use the following command to identify the CPLD version:

Dell#show revision

— Stack unit 1 —
S6000-ON SYSTEM CPLD    : 10

S6000-ON MASTER CPLD   : 12

S6000-ON SLAVE CPLD       : 10
Dell#

Use the following command to view CPLD version that is associated with the Dell Networking OS image:

Dell# show os-version

RELEASE IMAGE INFORMATION :
———————————————————————
Platform                Version           Size             ReleaseTime
S-Series:SI-ON    9.14(2.11)    63304169    Oct 18 2021 09:47:31

TARGET IMAGE INFORMATION :
———————————————————————
Type               Version                           Target    checksum
runtime         9.14(2.11)      Control Processor         passed

BOOT IMAGE INFORMATION :
———————————————————————
Type               Version                          Target    checksum
boot flash      3.20.2.5        Control Processor        passed

BOOTSEL IMAGE INFORMATION :
———————————————————————
Type               Version                          Target    checksum
boot selector   3.20.0.3        Control Processor        passed

FPGA IMAGE INFORMATION :
———————————————————————
Card                                         FPGA Name       Version
stack-unit 1       S6000-ON SYSTEM CPLD              10
stack-unit 1       S6000-ON MASTER CPLD             12
stack-unit 1           S6000-ON SLAVE CPLD             10
Dell#

Upgrading the CPLD Image

The upgrade fpga-image stack-unit 1 booted command is hidden when using the FPGA Upgrade feature in the CLI. However, it is a supported command and will be accepted when entered as documented.

Ensure that the BIOS version is 3.20.0.3 or above. You can verify this version using show system stack-unit 1 command.

To upgrade the CPLD image on S6000-ON, follow these steps:

1. Upgrade the CPLD image.

EXEC Privilege Mode

upgrade fpga-image stack-unit [1–6] booted

Dell# upgrade fpga-image stack-unit 1 booted

Current information for the system:

Card                             Device Name   Current Version   New Version
——————————————————————
Unit1     S6000-ON SYSTEM CPLD                       10                     10
Unit1     S6000-ON MASTER CPLD                       12                     12
Unit1         S6000-ON SLAVE CPLD                       10 10


  Warning – Upgrading FPGA is inherently risky and should                         
  only be attempted when necessary. A failure at this upgrade may               
  cause a board RMA. Proceed with caution !                                               


Upgrade image for stack-unit 1 [yes/no]:

2. Power cycle the system physically. Switch off the system by unplugging the power chords from the REAR PSUs and wait until the PSU FAN–REAR STATUS LED is completely OFF.

Do not switch on the system with PSU–REAR LED glowing AMBER.

3. Switch on the system and wait for the Dell prompt. The CPLD version can be verified using the show revision command.

EXEC Privilege Mode

show revision

Dell#show revision

— Stack unit 1 —
S6000-ON SYSTEM CPLD     : 10

S6000-ON MASTER CPLD    : 12

S6000-ON SLAVE CPLD        : 10
Dell#

Do not use power-cycle stack-unit command to power cycle the system and do not power off the system while FPGA upgrade is in progress. For any queries, contact technical support.

Uninstalling Dell Networking OS from the S6000-ON

To uninstall the Dell Networking OS version 9.14(2.11) from the S6000-ON device, perform the following steps:

1. Reboot the system. During the reboot process, the system displays the following message prompting you to press the Esc key in order to stop the auto-boot process:

Version 2.15.1236. Copyright (C) 2021 American Megatrends, Inc.
BIOS Date: 10/18/2021 21:34:20 Ver: 0ACAH019
Press DEL or F2 to enter setup.

Grub 1.99~rc1 (Dell Inc)
Built by root at ubuntu on Mon_Oct_18_14:04:19_UTC_2021
S6000ON Boot Flash Label 3.20.2.5 NetBoot Label 3.20.2.5

Press Esc to stop autoboot … 5

2. At this prompt message, press the Esc key. The following menu appears:

+—————————————————————————-+
| FTOS
| FTOS-Boot Line Interface
| ONIE
+—————————————————————————-+

3. From the menu, choose the ONIE option.

To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.

The following menu appears:

+——————————————————————+
| ONIE: Install OS                                                   |
| ONIE: Rescue                                                        |
|*ONIE: Uninstall OS                                              |
| ONIE: Update ONIE                                            |
| ONIE: Embed ONIE                                            |
| ONIE: Diag                                                           |
| PLATFORM-DIAG x86_64-dell_s6000_s1220-r0 |
+——————————————————————-+

4. From this menu, choose the ONIE : Uninstall OS option.

To choose an option from the menu, highlight one of the options using the up or down arrow key and press Enter.

The uninstall process begins. Following is the log generated by the system while Dell Networking OS 9.14(2.11) uninstalls:

ONIE: OS Uninstall Mode …
Version : feature/workspace-202110181619-dirty
Build Date: 2021-10-180T16:22-0700
Info: Mounting kernel filesystems… done.
Info: Mounting LABEL=ONIE-BOOT on /mnt/onie-boot …
Info: Using eth0 MAC address: 90:b1:1c:f4:a2:4d
Info: eth0: Checking link… up.
Info: Trying DHCPv4 on interface: eth0
DHCPv4 on interface: eth0 failedONIE: Using default IPv4 addr: eth0:
192.168.3.10/255.255.255.0
Starting: dropbear ssh daemon… done.
Starting: telnetd… done.
discover: Uninstall mode detected. Running uninstaller.
Erasing internal mass storage device: /dev/sda4 (32MB)

Percent complete: 100%

Erase complete.
Deleting partition 4 from /dev/sda
Erasing internal mass storage device: /dev/sda5 (300MB)

Percent complete: 100%

Erase complete.
Deleting partition 5 from /dev/sda
Erasing internal mass storage device: /dev/sda6 (300MB)

Percent complete: 100%

Erase complete.
Deleting partition 6 from /dev/sda
Erasing internal mass storage device: /dev/sda7 (14032MB)

Percent complete: 100%

Erase complete.
Deleting partition 7 from /dev/sda
Installing for i386-pc platform.
Installation finished. No error reported.
Uninstall complete. Rebooting…
umount: can’t remount rootfs read-only
The system is going down NOW!
Sent SIGTERM to all processes
Sent SIGKILL to all processes
Requesting system reboot
sd 0:0:0:0: [sda] Synchronizing SCSI cache
Restarting system.
machine restart
BIOS (Dell Inc) Boot Selector
S6000-ON (SI) 3.20.0.3 (32-port TE/FG)

POST Configuration

CPU Signature 30669
CPU FamilyID=6, Model=36, SteppingId=9, Processor=0
Microcode Revision 10b
POST Control=0xea000303, Status=0xe6009f00

MSRs:

Platform ID: f09884f046
PMG_CST_CFG_CTL: 263006
BBL_CR_CTL3: 7e00010f
Perf Ctrl & status: 63d, 63d104606000648

Perf cnt (curr/fixed): 17d50cf4/3f8d8e10
Clk Flex Max: 0
Misc EN: 60840080
Therm Status: 88440000 (offset=0x0)
MC0 Ctl: 0
MC0 Status: 0

BIOS initializations…

CPGC Memtest for rank 0 ………………… PASS

CPGC Memtest for rank 1 ………………… PASS

POST:

RTC Battery ok at last cold boot (0xb)
RTC date Monday 10/18/2021 22:20:38

POST SPD test …………………………. PASS

POST Lower DRAM Memory test

SpeedStep enabled, Processor Bus Ratio=10, Vid=51

Short memory cell test

Perf cnt (curr/fixed): 24e32568/24e48b08

POST Lower DRAM Memory test …………….. PASS
POST Lower DRAM ECC check ………………. PASS

DxE POST

POST Upper DRAM Memory test

SpeedStep enabled, Processor Bus Ratio=10, Vid=51

Short memory cell test

Perf cnt (curr/fixed): ba0ec40/ba0ede8

POST Upper DRAM Memory test …………….. PASS
POST Upper DRAM ECC check ………………. PASS

POST PCIe test ………………………… PASS
POST NVRAM check ………………………. PASS

POST overall test results ………………. PASS

POST SPD test …………………………. PASS

POST Lower DRAM Memory test

SpeedStep enabled, Processor Bus Ratio=10, Vid=51

Short memory cell test

Perf cnt (curr/fixed): 24e4db50/24e640f0

POST Lower DRAM Memory test …………….. PASS
POST Lower DRAM ECC check ………………. PASS

DxE POST
POST Upper DRAM Memory test

SpeedStep enabled, Processor Bus Ratio=10, Vid=51

Short memory cell test

Perf cnt (curr/fixed): ba5bf38/ba5c0d8

POST Upper DRAM Memory test …………….. PASS
POST Upper DRAM ECC check ………………. PASS

POST PCIe test ………………………… PASS
POST NVRAM check ………………………. PASS

POST overall test results ………………. PASS

5. After the installation completes, the system displays the following ONIE prompt:

ONIE:/ #

Documentation Corrections

This section describes the errors identified in the current release of the Dell Networking OS.

  • The router bgp command allows you to configure only one L3 interface with an IPv4 address. The Configuration guide does not mention this limitation and will be corrected in the next release of the guide.

Deferred Issues

Issues that appear in this section were reported in Dell Networking OS version 9.14(2.0) as open, but have since been deferred.
Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution.

Deferred issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a

running process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

Deferred S6000-ON 9.14(2.0) Software Issues

Issues that appear in this section were reported in Dell Networking OS version 9.14(2.0) as open, but have since been deferred.
Deferred caveats are those that are found to be invalid, not reproducible, or not scheduled for resolution.

The following issues have been deferred in the Dell Networking OS version 9.14(2.0):
None.

Fixed Issues

Fixed issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a

running process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

Fixed S6000-ON 9.14(2.11) Software Issues

Dell Networking OS 9.14(2.11) includes fixes for caveats addressed in the previous 9.14 releases. Refer to the respective release notes documentation for the list of caveats fixed in the earlier 9.14 releases.

The following caveats are fixed in Dell Networking OS version 9.14(2.11):

PR# 170066

Severity Sev 3
Synopsis In certain scenarios, performing ssh to a switch may not work

as expected.
Release Notes| In certain scenarios, performing ssh to a switch may not work as expected.
Workaround| None

PR# 170093

Severity Sev 3
Synopsis OpenSSH version 8.6p1 that is bundled with 9.14.2.11, fixes

vulnerabilities reported by CVE-2020-12062 and CVE-2020-15778.
Release Notes| OpenSSH version 8.6p1 that is bundled with 9.14.2.11, fixes vulnerabilities reported by CVE-2020-12062 and CVE-2020-15778.
Workaround| None

PR# 170151

Severity Sev 2
Synopsis A memory leak and stacking protocol loop may be seen when more

than two stack links are connected in a stack group.
Release Notes| A memory leak and stacking protocol loop may be seen when more than two stack links are connected in a stack group.
Workaround| None

PR# 170159

Severity Sev 3
Synopsis SSH connections with Cipher Block Chaining (CBC) ciphers are

vulnerable.
Release Notes| SSH connections with Cipher Block Chaining (CBC) ciphers are vulnerable.
Workaround| Configure a stronger Cipher/MAC/KEX setting using the ip ssh server command.

PR# 170161

Severity Sev 2
Synopsis SSH connections may be vulnerable with switches running on a

1024 bit RSA key.
Release Notes| SSH connections may be vulnerable with switches running on a 1024 bit RSA key.
Workaround| Create a new 2048 bit RSA key using the crypto key generate rsa command.

PR# 170179

Severity Sev 2
Synopsis In certain scenarios, the switch may encounter an exception

when trying to ssh into it.
Release Notes| In certain scenarios, the switch may encounter an exception when trying to ssh into it.
Workaround| None

PR# 170198

Severity Sev 2
Synopsis A BGP route added using the network command does not get

deleted even when the contributing route is deleted.
Release Notes| A BGP route added using the network command does not get deleted even when the contributing route is deleted.
Workaround| None

Known Issues

Known issues are reported using the following definitions.

Category Description
PR# Problem Report number that identifies the issue.
Severity S1 — Crash: A software crash occurs in the kernel or a

running process that requires a restart of AFM, the router, switch, or process.
S2 — Critical: An issue that renders the system or a major feature unusable, which can have a pervasive impact on the system or network, and for which there is no work-around acceptable to the customer.
S3 — Major: An issue that affects the functionality of a major feature or negatively effects the network for which there exists a work-around that is acceptable to the customer.
S4 — Minor: A cosmetic issue or an issue in a minor feature with little or no network impact for which there might be a work-around.
Synopsis| Synopsis is the title or short description of the issue.
Release Notes| Release Notes description contains more detailed information about the issue.
Work around| Work around describes a mechanism for circumventing, avoiding, or recovering from the issue. It might not be a permanent solution.
Issues listed in the “Closed Caveats” section should not be present, and the work-around is unnecessary, as the version of code for which this release note is documented has resolved the caveat.

KnownS6000-ON 9.14(2.11) Software Issues

The following caveats are open in Dell Networking OS version 9.14(2.11):
None

Support Resources

The following support resources are available for theS6000 system.

Documentation Resources

This document contains operational information specific to the S6000–ON system.

For information about using the S6000–ON, refer to the following documents at http://www.dell.com/support:

  • Installing the S6000-ON System
  • Quick Start Guide
  • Dell Networking Command Line Reference Guide for the S6000-ON System
  • Dell Networking Configuration Guide for the S6000-ON System

For more information about hardware features and capabilities, refer to the Dell Networking website at https://www.dellemc.com/networking.

For more information about the open network installation environment (ONIE)-compatible third-party operating system, refer to http://onie.org.

Issues

Issues are unexpected or incorrect behavior and are listed in order of Problem Report (PR) number within the appropriate sections.

Finding Documentation

This document contains operational information specific to the S6000–ON system.

  • For information about using the S6000–ON, refer to the documents at http://www.dell.com/support.
  • For more information about hardware features and capabilities, refer to the Dell Networking website at https://www.dellemc.com/networking.
  • For more information about the open network installation environment (ONIE)-compatible third-party operating system, refer to http://onie.org.
Contacting Dell

If you do not have an active Internet connection, you can find contact information on your purchase invoice, packing slip, bill, or Dell product catalog.

Dell provides several online and telephone-based support and service options. Availability varies by country and product, and some services may not be available in your area. To contact Dell for sales, technical support, or customer service issues:

Go to www.dell.com/support.

Notes, cautions, and warnings

A NOTE indicates important information that helps you make better use of your product.

A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.

A WARNING indicates a potential for property damage, personal injury, or death.

© 2021 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

DELL Technologies User Manuals

Related Manuals