DELL Technologies S6000 System 9.14 2.14 Release Notes User Guide
- June 12, 2024
- DELL Technologies
Table of Contents
- DELL Technologies S6000 System 9.14 2.14 Release Notes
- Product Information
- Product Usage Instructions
- Dell System S6000 9.14(2.14) Release Notes
- Restrictions
- Supported Hardware
- S6000 Upgrade Procedures Overview
- Upgrading the CPLD
- **** Upgrading the CPLD Image
- VLT Upgrade Procedure
- Documentation Corrections
- Support Resources
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DELL Technologies S6000 System 9.14 2.14 Release Notes
Product Information
Product Name: Dell System S6000
Release Version: 9.14(2.14)
Release Date: April 2022
Manufacturer: Dell Technologies
Product Description: The Dell System S6000 is a networking platform that
runs on the Dell Networking OS software. It provides various features and
capabilities for networking purposes.
Product Usage Instructions
- Before upgrading to version 9.14.2.x from an earlier OS9 version, ensure you first upgrade to version 9.13.0.0 to prevent any issues during the upgrade procedure.
- To verify the error-disabled status of an interface, enter any of the following show commands:
Dell# show inventory media
Dell# show interfaces fortyGigE 1/49
- To upgrade the Dell Networking OS from an earlier version to 9.14.2.0 or later, follow these prerequisite steps:
- Uninstall the older version of the Open Automation (OA) package.
- Upgrade the Dell Networking OS to 9.14.2.0 or later version.
- Install the following OA packages from the respective upgraded version:
* SmartScripts
* Puppet
* Open management infrastructure (OMI)
* SNMP MIB
- To downgrade the Dell Networking OS from 9.14.2.0 or later to an earlier version, follow these prerequisite steps:
- Uninstall the OA package of 9.14.2.0 or later version.
- Downgrade the Dell Networking OS to an earlier version.
- Install the respective OA package from an earlier version.
- If you downgrade the Dell Networking OS version from 9.14.2.14 to 9.11.0.0 or any older versions, the system may display the following error message:
CDB boot error: C.cdb file format
Before downgrading, save the current configuration and then remove the CDB files (confd_cdb.tar.gz.version and confd_cdb.tar.gz) using the provided steps.
For more detailed information about installing, uninstalling, and upgrading the Dell Networking OS and OA package, refer to the respective Dell System Release Notes.
Dell System S6000 9.14(2.14) Release Notes
This document contains information on open and resolved caveats, and
operational information specific to the Dell Networking OS software and the
S6000 platform.
Current Release Version : 9.14(2.14)
Release Date: 2022-04-15
Previous Release Version: 9.14(2.12)
NOTE : This document may contain language that is not consistent with
current guidelines of Dell Technologies. There are plans to update this
document over subsequent releases to revise the language accordingly.
Incorrect behavior or unexpected caveats are listed as the Problem Report (PR)
numbers within the appropriate sections.
For more information on hardware and software features, commands, and
capabilities, refer to the Dell Networking website at:
https://www.dellemc.com/networking.
Document Revision History
Table 1. Revision History
Date | Description |
---|---|
2022–04 | Initial release. |
New Dell Networking OS Version 9.14(2.14) Features
The following features are integrated into the Dell Networking 9.14.2 branch
through this release:
- None
Changes to Default Behavior and CLI Syntax
- If you are upgrading from an earlier OS9 version to 9.14.2.x, ensure you first upgrade to version 9.13.0.0 before upgrading to the required version of 9.14.2.x to prevent any issues during the upgrade procedure.
Restrictions
- You can use non-Dell qualified cables, adapters, and optics in a S6000 switch, but Dell Networking does not guarantee their performance as the S6000 does not support non-Dell qualified transceivers of 25G and above. If you insert
a non-Dell qualified transceiver of 25G and above into a SFP28, QSFP+, or QSFP28 port, the switch places the interface in an error-disabled (operationally down) state and generates a syslog message, such as: %S6000LC0640:8 %IFAGT-2-TRANSCEIVER_UNSUPPORTED_ERROR: Transceiver in slot 1 port 49 unrecognized, putting interface in operational-down state.
To verify the error-disabled status of an interface, enter any of the following show commands.
Prerequisite steps to upgrade the Dell Networking OS from earlier version to 9.14.2.0 or later:
- Uninstall the older version of the Open Automation (OA) package
- Upgrade the Dell Networking OS to 9.14.2.0 or later version
- Install the following OA packages from the respective upgraded version:
a. SmartScripts
b. Puppet
c. Open management infrastructure (OMI)
d. SNMP MIB
Prerequisite steps to downgrade the Dell Networking OS from 9.14.2.0 or later to the earlier version:
- Uninstall the OA package of 9.14.2.0 or later version
- Downgrade the Dell Networking OS to an earlier version
- Install the respective OA package from an earlier version
For more information about installing, uninstalling and upgrading the Dell Networking OS and OA package, refer the respective Dell System Release Notes.
- If you downgrade the Dell Networking OS version from 9.14.2.14 to 9.11.0.0 or any older versions, the system displays the following error message even though there is no functional impact:
Before downgrading, save the current configuration and then remove the CDB files (confd_cdb.tar.gz.version and confd_cdb.tar.gz). To remove the files, use the following steps:
Dell#write memory
Dell#delete flash://confd_cdb.tar.gz.version
Dell#delete
flash://confd_cdb.tar.gz
- While deploying the system in the normal-reload mode in BMP configuration, use the ip ssh server enable command at the beginning of the startup configuration if the write memory command is used at the end of the configuration.
- REST API does not support AAA authentication.
- The following features are not available in the Dell Networking OS from version 9.7(0.0):
- PIM ECMP
- Static IGMP join (ip igmp static-group)
- IGMP querier timeout configuration (ip igmp querier-timeout)Dell#reload
- IGMP group join limit (ip igmp group join-limit)
- Half-Duplex mode is not supported.
- When FRRP is enabled in a VLT domain, no flavor of Spanning tree should concurrently be enabled on the nodes of that specific VLT domain. In essence FRRP and xSTP should not co-exist in a VLT environment.
Supported Hardware
The following hardware is supported with this platform:
Hardware
S6000 chassis
32 40Gbps QSFP+ ports
2 AC/DC PSUs
3 fan subsystems
USB Error Messages
NOTE : If all the three fan trays are found to be empty or faulty, the
system will shut down after one minute.
NOTE: The rear rack mounting bracket (SA-01-RMB-8) will fit only into
racks with depths in the following ranges:
- 22.98 in. to 24.65 in.
- 27.86 in. to 30.34 in.
The following informational error message appear when a USB thumb drive is
inserted or removed from the system. No action needs to be taken when these
messages appear.
Internal Messages
Removal Messages
S6000 Upgrade Procedures Overview
To upgrade the Dell Networking OS to the latest version, complete these steps:
NOTE: When upgrading from an earlier version of OS9 (example: 9.10.0.1)
to 9.14.2.x, first upgrade to 9.13.0.0 to prevent any issues during the
upgrade procedure.
- Upgrading the S6000 Dell Networking OS Image and Boot Code
- Upgrading the CPLD
- VLT Upgrade Procedure
Upgrading the S6000 Dell Networking OS Image and Boot Code
The S6000 system is pre-loaded with default Dell Networking OS software.
-
NOTE : If you downgrade from Dell Networking OS version 9.14(2.14) to version 9.6(0.0) or any version prior to 9.6(0.0), any existing quad mode configuration on the following ports is removed: 4, 12, 20, 28, 100, 108, 116, and 124
-
NOTE : If you downgrade from Dell Networking OS version 9.14(2.14) to 9.0(2.0), remove any existing quad mode configuration from the following 40G ports: 4, 12, 20, 28, 100, 108, 116, and 124. To remove any quad mode configuration,
use the no stack-unit port portmode quad command in CONFIGURATION mode and then save the configuration using the write memory command in EXEC PRIVILEGE mode. -
NOTE:
Before upgrading the OS to version 9.14(2.14), uninstall the older version of the Open Automation package. Upgrade the OS to 9.14(2.14) and then install the latest OA package.
If you downgrade the OS from version 9.14(2.14) to an earlier version, uninstall the older OA package first. Downgrade the OS to an earlier version and then install the relevant OA package version.
Bare Metal Provisioning
NOTE : If you are using Bare Metal Provisioning (BMP), refer to the
Bare Metal Provisioning chapter in the Dell Networking OS Configuration Guide
or the Open Automation Guide.
Manual Upgrade Procedure
Follow these steps carefully to upgrade your S6000 systems:
-
Dell Networking recommends that you back up your startup configuration and any important files and directories to an external media prior to upgrading the system.
-
Upgrade the Dell Networking OS in flash partition A: or B: EXEC Privilege Mode
upgrade system [flash: | ftp: | stack-unit <0-5 | all> | tftp: | scp: | usbflash:] [A: |B:] -
In case of a stack setup, upgrade the Dell Networking OS for the stacked units.
EXEC Privilege Mode
upgrade system stack-unit [0-11 | all] [A: | B:] If A: is specified in the command, the Dell Networking OS version present in Management unit’s A: partition will be pushed to the stack units. If B: is specified in the command, the Management unit’s B: will be pushed to the stack units. Upgrade of stack units can be done on individual units by specifying the unit id [0-5] or on all units by using all in the command. -
Verify the Dell Networking OS has been upgraded correctly in the upgraded flash partition.
EXEC Privilege Mode
show boot system stack-unit [0–5 | all] -
Upgrade the S6000 Boot Flash and Boot Selector images.
EXEC Privilege Mode
upgrade boot [all | bootflash-image | bootselector-image] stack-unit [0-5 | all] [booted | flash: | ftp: | scp: | tftp: | usbflash:] Dell Networking OS version 9.14(2.14) requires S6000 Boot Flash image version 3.1.1.7 and Boot Selector image version 3.1.0.3. The Boot Flash and Boot Selector images can be upgraded together by selecting all in the command. If the user wishes to upgrade Boot Flash image or Boot Selector image separately, the options bootflash-image or bootselector-image needs to be given separately in the command. The booted option is used to upgrade the Boot flash and Boot Selector images to the image versions packed with the loaded Dell Networking OS image. The Boot Flash and Boot Selector image versions packed with the loaded Dell Networking OS can be found using the show os-version command in EXEC PRIVILEGE mode.
NOTE : The Boot Flash version packed in Dell Networking OS 9.14(2.14) for S6000 system is 3.1.1.7. Upgrade of Boot Flash to version 3.1.1.7 is not mandatory for proper functioning of the system. -
Change the Primary Boot Parameter of the S6000 to the upgraded partition A: or B: CONFIGURATION Mode boot system stack-unit [0–5 | all] primary system: [A: | B: | tftp: | ftp:]
-
Save the configuration so that the configuration will be retained after a reload using write memory command. EXEC Privilege Mode write memory
-
Reload the unit.
EXEC Privilege Mode reload -
Verify the S6000 has been upgraded to the Dell Networking OS version 9.14(2.14).
EXEC Privilege Mode show version -
Verify that the S6000 has been upgraded to the latest Boot Flash and Boot Selector images
EXEC Privilege Mode
show system stack-unit [0-5]
SMARTSCRIPTS
To uninstall and install new SMARTSCRIPTS packages after upgrading to Dell
Networking OS, refer to the Open Automation Guide.
Upgrading the CPLD
The S6000 system with Dell Networking OS Version 9.14(2.14) requires System
CPLD revision 10, Master CPLD revision 12, and Slave CPLD revision 10.
Verify that a CPLD upgrade is required
NOTE : If your CPLD revisions are higher than the ones shown here, DO NOT
make any changes. If you have questions regarding the CPLD revision, contact
technical support.
Use the following command to identify the CPLD version:
Use the following command to view CPLD version that is associated with the Dell Networking OS image:
**** Upgrading the CPLD Image
NOTE: The upgrade fpga-image stack-unit 0 booted command is hidden when
using the FPGA Upgrade feature in the CLI. However, it is a supported command
and will be accepted when entered as documented.
NOTE : Ensure that the BIOS version is 3.1.0.3 or above. You can verify
this version using the show system stack-unit 0 command.
To upgrade the CPLD image on S6000, follow these steps:
-
Upgrade the CPLD image.
EXEC Privilege Mode upgrade fpga-image stack-unitbooted -
Power cycle the system physically. Switch off the system by unplugging the power chords from the REAR PSUs and wait until the PSU FAN–REAR STATUS LED is completely OFF.
NOTE : Do not switch on the system with PSU–REAR LED glowing AMBER. -
Switch on the system and wait for the Dell prompt. The CPLD version can be verified using the show revision command.
EXEC Privilege Mode show revision NOTE : Do not power off the system while FPGA upgrade is in progress. For any queries, contact technical support
VLT Upgrade Procedure
Follow this procedure to upgrade the system from release 9.4(2.8) to the latest version in a VLT setup:
-
Upgrade the system-flash partition A or B with the new image on both VLT peers.On both the VLT peers, set Primary boot parameter to boot the system from upgraded system flash partition [A or B].You can enter one of the following options:flash— Copies from flash file system (flash://filepath).ftp — Copies from remote file system (ftp://userid:password@hostip//filepath).scp — Copies from remote file system (scp://userid:password@hostip//filepath).tftp — Copies from remote file system (tftp://hostip/filepath).
EXEC Privilege Mode
upgrade system [flash: | ftp: | scp: | tftp: | usbflash:] [A: | B:] -
Reload or power-cycle one of the VLT peers (For Example, Peer 2).
EXEC Privilege Mode reload or power cycle -
Wait for Peer 2 to come up; VLT adjacency will be established. (Peer 2 – new image and Peer 1 – old image).
-
Wait for the Peer 2 to bring up all VLT LAG ports. Use the command show vlt detail to confirm all VLT ports in the local chassis are active.
EXEC Privilege Mode show vlt detail -
Following upgrade, use the write memory command to save the running-config to memory.
EXEC Privilege Mode write memory -
Ensure both the nodes are now forwarding traffic.
-
When all VLT ports are active on the Peer 2, repeat steps 2 through 5 for the Peer 1.
Documentation Corrections
This section describes the errors identified in the current release of the Dell Networking OS.
- The router bgp command allows you to configure only one L3 interface with an IPv4 address. The Configuration guide does not mention this limitation and will be corrected in the next release of the guide.
Deferred Issues
Issues that appear in this section were reported in Dell Networking OS version
9.14(2.0) as open, but have since been deferred. Deferred caveats are those
that are found to be invalid, not reproducible, or not scheduled for
resolution.
Deferred issues are reported using the following definitions.
Deferred S6000 9.14(2.0) Software Issues
Issues that appear in this section were reported in Dell Networking OS version
9.14(2.0) as open, but have since been deferred. Deferred caveats are those
that are found to be invalid, not reproducible, or not scheduled for
resolution.
The following issues have been deferred in the Dell Networking OS version
9.14(2.0):
- None.
Fixed Issues
Fixed issues are reported using the following definitions.
Fixed S6000 9.14(2.14) Software Issues
NOTE : Dell Networking OS 9.14(2.14) includes fixes for caveats
addressed in the previous 9.14 releases. Refer to the respective release notes
documentation for the list of caveats fixed in the earlier 9.14 releases.
The following caveats have been fixed in Dell Networking OS version
9.14(2.14):
PR# 170114
- Severity : Sev 2
- Synopsis : The switch experiences memory leaks when processing certain types of packets.
- Release Notes : The switch experiences memory leaks when processing certain types of packets.
- Workaround : None
PR# 170232
- Severity : Sev 2
- Synopsis: The switch sends deprecated VRRP traps.
- Release Notes: The switch sends deprecated VRRP traps.
- Workaround : None
PR# 170301
- Severity : Sev 3
- Synopsis : The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli (CVE-2022-0778).
- Release Notes : The BN_mod_sqrt() function, which computes a modular square root, contains a bug that can cause it to loop forever for non-prime moduli (CVE-2022-0778).
- Workaround : None
Known Issues
Known issues are reported using the following definitions.
KnownS6000 9.14(2.14) Software Issues
The following caveats are open in Dell Networking OS version 9.14(2.14):
- None
Support Resources
The following support resources are available for theS6000 system.
Documentation Resources
This document contains operational information specific to the S6000 system.
For information about using the S6000, refer to the following documents at
http://www.dell.com/support:
- Installing the S6000 System
- Quick Start Guide
- Dell Networking Command Line Reference Guide for the S6000 System
- Dell Networking Configuration Guide for the S6000 System
For more information about hardware features and capabilities, refer to the
Dell Networking website at https://www.dellemc.com/networking.
For more information about the open network installation environment
(ONIE)-compatible third-party operating system, refer to http://onie.org.
Issues
Incorrect behavior or unexpected caveats are listed as the Problem Report (PR)
numbers within the appropriate sections.
Finding Documentation
This document contains operational information specific to the S6000 system.
- For information about using the S6000, refer to the documents at http://www.dell.com/support.
- For more information about hardware features and capabilities, refer to the Dell Networking website at https://www.dellemc.com/networking.
- For more information about the open network installation environment (ONIE)-compatible third-party operating system, refer to http://onie.org.Contacting Dell
NOTE: If you do not have an active Internet connection, you can find
contact information on your purchase invoice, packing slip, bill, or Dell
product catalog.
Dell provides several online and telephone-based support and service options.
Availability varies by country and product, and some services may not be
available in your area. To contact Dell for sales, technical support, or
customer service issues: Go to
www.dell.com/support.
Notes, cautions, and warnings
- NOTE : A NOTE indicates important information that helps you make better use of your product.
- CAUTION : A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
- WARNING : A WARNING indicates a potential for property damage, personal injury, or death.
© 2022 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
References
- Computers, Monitors & Technology Solutions | Dell USA
- Support | Dell US
- Dell Networking Solutions | Dell USA
- Dell Networking Solutions | Dell USA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>