TOSHIBA RBC-AXU33UP-E Wireless Remote Controller Kit User Manual
- June 12, 2024
- Toshiba
Table of Contents
RBC-AXU33UP-E Wireless Remote Controller Kit
Product Information: Product Name: AIR CONDITIONER
(ACCESSORIES) Model: RBC-AXU33UP-E Type: Wireless remote controller
kit (For 4-way cassette type) Language: English Product Usage
Instructions: 1. Safety Precautions: – Before using the
product, please refer to the Installation manual provided with the
ceiling panel and air conditioner (indoor unit) and follow the
safety precautions mentioned. 2. Parts of the Remote Controller: –
Infrared signal emitter: Transmits a signal to the indoor unit. –
START/STOP button: Press to start or stop the operation. If no
receiving sound is heard from the indoor unit, press the button
twice. – Mode select button (MODE): Press to select a mode (Auto,
Cool, Dry, Heat, Fan only). Each press will cycle through the
modes. – Temperature button: Press to adjust the temperature. – Fan
speed button (FAN): Press to select fan speed. AUTO adjusts speed
automatically based on room temperature. Manual selection is also
available (LOW, LOW+, MED, MED+, HIGH). – Auto louver button
(SWING): Press to swing the louver. Press again to stop swinging. –
Set louver button (FIX): Press to adjust the airflow direction.
Keep depressed for continuous adjustment. – Off timer button (OFF):
Press to set the OFF timer. – On timer button (ON): Press to set
the ON timer. – Reserve button (SET): Press to reserve time
settings. – Cancel button (CLR): Press to cancel ON timer and OFF
timer. – High power button (Hi POWER): Press to start high power
operation (not applicable to group control). – PRESET button: Press
to change the operation mode to a previously memorized mode by
pressing for at least 3 seconds during the preferred mode. P is
displayed to indicate the memorized mode. 3. Operating
Instructions: – Ensure that the safety precautions mentioned in the
user manual are followed. – Use the START/STOP button to turn on or
off the air conditioner. Press once to start and press again to
stop. – Use the MODE button to cycle through different operating
modes (Auto, Cool, Dry, Heat, Fan only). – Adjust the temperature
using the temperature button. – Select the desired fan speed using
the FAN button. AUTO adjusts speed automatically, while manual
selection is also possible. – Use the SWING button to swing the
louver and adjust the airflow direction using the FIX button. – Set
the OFF timer and ON timer using the respective buttons. – Reserve
time settings by pressing the SET button. – Cancel ON timer and OFF
timer by pressing the CLR button. – Start high power operation by
pressing the Hi POWER button (not applicable to group control). –
Change to a previously memorized mode by pressing the PRESET button
for at least 3 seconds during the desired mode. Please refer to the
complete user manual for detailed instructions and additional
information.
AIR CONDITIONER (ACCESSORIES)
Operations Manual
Wireless remote controller kit (For 4-way cassette type) Model name:
RBC-AXU33UP-E
English
Operations Manual
Thank you very much for purchasing TOSHIBA Air Conditioner. Please read this
owner’s manual carefully before using your Air Conditioner. · Be sure to
obtain the “Owner’s manual” and “Installation manual” from constructor (or
dealer). · Request to constructor or dealer. · Please clearly explain the
contents of the Owner’s manual and hand over it.
Observe the safety precautions described in the Installation manual supplied
with the ceiling panel and air conditioner (indoor unit).
Contents
1 ACCESSORIES ……………………………………………………………………………………………………………………………… 2 2 PARTS NAME
OF REMOTE CONTROLLER …………………………………………………………………………………….. 3 3 ADJUSTING
CLOCK………………………………………………………………………………………………………………………. 5 4 LIMITED OPERATION BY
GROUP CONTROL ………………………………………………………………………………….. 6 5 HANDLING THE REMOTE
CONTROLLER……………………………………………………………………………………….. 7 6 HOW TO USE REMOTE
CONTROLLER…………………………………………………………………………………………… 8 7 TEMPORARY OPERATION
…………………………………………………………………………………………………………… 14
1-EN
– 1 –
1 ACCESSORIES
Remote controller
Remote controller holder
Operations Manual Wireless receiver
Batteries (two)
Names and functions of indicators
and controls on Wireless receiver
Display panel
2
3 1
4
The operating conditions are indicated below.
1 TEMPORARY operation
If you misplace or lose the wireless remote controller or its batteries are
exhausted, push the temporary operation button. · Push the temporary operation
button to start the
air conditioner. Push this button once again to stop it.
2 OPERATION (White)
This lamp goes on during operation.
3 TIMER (White)
This lamp goes on white the timer reserved.
NOTE
In case of timer setting by wired remote controller, TIMER lamp does not
light. In case of group control, TIMER lamp goes on header unit only. (see “4
LIMITED OPERATION BY GROUP CONTROL”)
4 Preheat/Defrost (White)
This lamp lights up when the power is turned on or right after heating
operation starts or during defrost operation.
CAUTION
· Disagreement in operation mode If you select AUTOMATIC OPERATION in a model
with no auto-changeover (cooling/ heating) control setting or if you select
HEAT in a Cool Only model, an alarm sound (pi, pi) from the air conditioner
due to disagreement in operation mode. Change the operation mode with the MODE
button on the wireless remote controller. This disagreement indication cannot
be deleted by the wired remote controller.
· When local prohibition is set by the central control from other equipment,
no signal is received even if the remote controller button is pressed.
However, a signal of START/STOP button is accepted. (An alarm sound “pi ”
arises intermittently five times.)
– 2 –
2-EN
Operations Manual
2 PARTS NAME OF REMOTE CONTROLLER
Names and functions of indicators
and controls on indoor unit
1
13
2
4
3
6
7
SWING FAN
5
FIX QUIET
15
Hi POWER
12
11
9 14
COMFORT SLEEP
8 10
1 Infrared signal emitter
Transmits a signal to the indoor unit.
2 START/STOP button
Press the button to start operation. (A receiving beep is heard.) Press the
button again to stop operation. (A receiving beep is heard.) If no receiving
sound is heard from the indoor unit, press the button twice.
3 Mode select button (MODE)
Press this button to select a mode. Each time you press the button, a mode is
selected in a sequence that goes from A : Auto, : Cool,
: Dry, : Heat, : Fan only, and back to A. (A receiving beep is heard.)
4 Temperature button ( )
…………. The set temperature is increased up to 30°C.
…………. The set temperature is dropped down to 17°C. (A receiving beep is
heard.)
5 Fan speed button (FAN)
Press this button to select fan speed. When you select AUTO, the fan speed is
automatically adjusted according to the room temperature.
You can also manually select the desired fan
speed from among five settings.
(LOW , LOW+ , MED
,
MED+
, HIGH
)
(A receiving beep is heard.)
6 Auto louver button (SWING)
Press this button to swing the louver. (A receiving beep is heard.) Press the SWING button to stop the louver swinging. (A receiving beep is heard.)
7 Set louver button (FIX)
Press this button to adjust the airflow direction. (A receiving beep is heard.) While this button is kept depressed, the receiving tone continuously sounds.
8 Off timer button (OFF)
Press this button to set the OFF timer.
9 On timer button (ON)
Press this button to set the ON timer.
10 Reserve button (SET)
Press this button to reserve time settings. (A receiving beep is heard.)
11 Cancel button (CLR)
Press this button to cancel ON timer and OFF timer. (A receiving beep is heard.)
12 High power button (Hi POWER)
Press this button to start the high power operation. This function is not operated group control.
13 PRESET button
Press this button to change the operation mode to the preferred operation mode memorized previously. To memorize the operation mode, press this button for at least 3 seconds during the preferred operation mode. P is displayed and the operation mode is memorized.
14 COMFORT SLEEP button
Press this button to start the OFF timer operation that automatically adjusts the room temperature and the fan speed. You can select the OFF timer time from four durations (1, 3, 5 or 9 hours). During group control operation, the set temperature and the fan speed are not automatically adjusted. Only off timer function is activated.
3-EN
– 3 –
Operations Manual
15 QUIET button
Press this button to start quiet operation. Pressing this button again will
restore normal operation.
Names and functions of indications
on wireless remote controller
Display
All indications, except for clock time indication, are
indicated by pressing the START/STOP
button.
1 32 10
8
7
9
5
6
4
· In the illustration, all indications are indicated for explanation. During operation, only the relevant indications will be indicated on the remote controller.
1 Transmission mark
This transmission mark ( ) indicates when the remote controller transmits signals to the indoor unit.
2 Mode display
Indicates the current operation mode. (A : Auto, : Cool, : Dry, : Heat,
: Fan only)
3 Temperature display
Indicates the temperature setting (17°C to 30°C).
When you set the operating mode to : Fan only, no temperature setting is
indicated.
4 FAN speed display
Indicates the selected fan speed. AUTO or one of five
fan speed levels
(LOW , LOW+ , MED
,
MED+
, HIGH
)
can be indicated. Indicates
when the
operating mode is : Dry.
5 TIMER and clock time display
The time set for timer operation or clock time is indicated. The present time
is always indicated except for TIMER operation.
6 Hi POWER display
Indicates when the high power operation starts. Press the Hi POWER button to start and press it again to stop the operation.
7 P (PRESET) display
Indicated when memorizing the preferred operation mode or when it has been memorized. Also, this icon is indicated when the memorized preferred operation is displayed.
8
(COMFORT SLEEP) display
Indicated during the OFF timer operation that automatically adjusts the room temperature and the fan speed. Each time you press the COMFORT SLEEP button, the display changes in the sequence of 1h, 3h, 5h, and 9h.
9
(QUIET) display
Indicated during the quiet operation.
10 Swing display
Indicated during the swinging operation where the horizontal louver automatically moves up and down.
NOTE
When both wired remote controller and wireless remote controller are used,
display on the screen of wireless remote controller may differ from the actual
operation in some cases.
Preparation and check before use
1. Loading Batteries · Remove the battery cover. · Insert 2 new batteries
(R03 [AAA]) following the (+) and (-) positions.
2. Removing Batteries · Remove the battery cover. · Remove the 2 used
batteries.
Batteries
· To replace the batteries, use two new batteries (R03 [AAA]).
· In normal use, the batteries will last about one year. · Replace the
batteries if there is no receiving beep from
the indoor unit or when the air conditioner cannot be operated using the
remote controller. · To avoid malfunctions by battery leakage, remove the
batteries when not using the remote controller for more than one month. ·
Please dispose of the used batteries according to the local regulation.
– 4 –
4-EN
Operations Manual
3 ADJUSTING CLOCK
Setting the clock
Before you start operating the air conditioner, set the clock of the remote
controller using the procedures given in this section. The clock panel on the
remote controller will indicate the time regardless of whether the air
conditioner is in use or not.
Clock adjusting
Initial setting
When batteries are inserted in the remote controller the clock panel will indicate AM 0:00 and will flash.
SWING FAN
FIX QUIET
Hi POWER
2
COMFORT SLEEP
3
SWING FAN
FIX QUIET
COMFORT SLEEP
Hi POWER
1 2
1
1 CLOCK button
Press the CLOCK by tip of a pencil. The CLOCK display flashes.
2 TIMER or button
1 TIMER or button
Press the TIMER or button to set the current time. Each press of the TIMER
button changes the time in one minute steps. Pressing the TIMER button
continually changes the time in ten minute steps.
2 SET button
Press the SET button. The current time is indicated and the clock starts.
Press the TIMER or button to set the current time. Each press of the TIMER
button changes the time by one minute. Pressing the TIMER button continually
changes the time by ten minutes.
3 SET button
Press the SET button. The current time is indicated and the clock starts.
5-EN
– 5 –
Operations Manual
4 LIMITED OPERATION BY GROUP CONTROL
NOTE Group control: Operate air conditioners in more than one system in same
time. Header indoor unit: The representative unit during group control.
Receive commands from wired remote controller and transmit the commands to
follower units. (Header indoor unit is indoor unit that receives START/STOP
signal from the wireless remote control.) Follower indoor unit: Indoor units
other than the Header unit are called follower unit. A wired remote controller
(separately available) is required for the group control.
Example of group combination
Indoor
Wired Remote controller
Indoor
Outdoor
Outdoor
Indoor Outdoor
Control line Other connecting line
CAUTION
When using indoor unit in group control, 1. Hi POWER operation will not
function.
When Hi POWER is transmitted from wireless remote controller the receiving
sound will be heard from the indoor unit and display on the wireless remote
controller will also change. However, the indoor unit does not operate Hi
POWER operation. Restore the display on the wireless remote controller pushing
Hi POWER button. 2. COMFORT SLEEP When COMFORT SLEEP is transmitted from
wireless remote controller, the receiving sound will be heard from the indoor
unit and the display on the wireless remote controller will also be changed as
same as Hi POWER operation. However, the set temperature and the fan speed
will not be automatically adjusted. Only off timer function is activated. 3.
Units other than the Header unit cannot be operated with remote controller and
the TEMPORARY operation. When operating air conditioner with wireless remote
controller transmission should be sent to the Header unit. Header and follower
indoor units are decided through address setting upon installation. Follower
unit will not receive any signals from wireless remote controller. Air
conditioner will not work even if the temporary operation button on the
follower unit is pressed. (Some Follower units may receive SWING and FIX, but
these operations are performed only on the unit that received the signal.)
(When wireless remote controller is used, only the Header unit receives SWING
signal. If the SWING signal is transmitted to follower unit, the sound to
refuse receiving signal (3 beeps) is heard and the follower unit does not
receive the signal. For FIX operation, both Header and follower unit perform
the operation by itself. When wired remote controller is used, airflow
direction can be changed on each unit by selecting the indoor unit.) 4. TIMER
lamp lights up only on the Header unit. When the timer is set with wired
remote controller, even the TIMER lamp on the Header unit will not light up.
– 6 –
6-EN
Operations Manual
5 HANDLING THE REMOTE CONTROLLER
CAUTION
· The air conditioner will not operate if curtains, doors or other materials
block the signals from the remote controller to the indoor unit.
· Prevent any liquid from falling into the remote controller. Do not expose
the remote controller to direct sunlight or heat.
· If the infrared signal receiver on the indoor unit is exposed to direct
sunlight, the air conditioner may not function properly. Use curtains to
prevent the sunlight from reaching the receiver.
· If the room using the air conditioner has fluorescent lighting with
electronic starters, signals may not be properly received. If you are planning
to use such fluorescent lamps, consult your local dealer.
· If other electrical appliances react to the remote controller move these
appliances or consult your local dealer.
Remote controller holder
Installing the remote controller holder
· Before you actually install the remote controller holder on a wall or
pillar, check whether the remote controller signals can be received by the
indoor unit.
Mounting and removing the remote controller
· To mount the remote controller hold it parallel to the remote controller
holder and push it in fully. To remove the remote controller slide the remote
controller upwards and out from the holder.
Location of the remote controller
· Keep the remote controller where its signals can reach the receiver of the
indoor unit (a distance of 7 m is allowed).
· When you select the timer operation, the remote controller automatically
transmits a signal to the indoor unit at the specified time. If you keep the
remote controller in a position that hinders proper signal transmission, a
time lag of up to 15 minutes may occur.
7 m
7-EN
– 7 –
6 HOW TO USE REMOTE CONTROLLER
Cooling/heating/fan only operation
Dry operation
Start
Start
Operations Manual
1
3
2
SWING FAN
4
1 3 2
SWING FAN
1 START/STOP button (
)
Press this button to start the air conditioner.
2 Mode select button (MODE)
Select Cool , Heat , or Fan only .
3 Temperature button ( )
Set the desired temperature. When the air conditioner is in FAN ONLY
operation, the temperature display is not indicated.
4 Fan speed button (FAN)
Select one of
LOW , LOW+ ,
MED
, MED+
, HIGH
.
· The OPERATION lamp on the display panel of the indoor unit goes on. And operation starts after approximately 3 minutes. (If you select FAN ONLY mode, the unit will start immediately.)
· The : Fan only mode does not control temperature.
· Fan speed
is the same as
HIGH
.
1 2 4 Therefore, perform only steps , and to select
this mode.
1 START/STOP button (
)
Press this button to start the air conditioner.
2 Mode select button (MODE)
Select Dry .
3 Temperature button ( )
Set the desired temperature.
· The fan speed display indicates
.
· The OPERATION lamp on the display panel of the indoor unit lights, and operation starts after approximately 3 minutes.
Stop
START/STOP button (
)
Press this button again to stop the air conditioner.
Stop
START/STOP button (
)
Press this button again to stop the air conditioner.
NOTE
When the indoor unit is operated together with a cooling only outdoor model
outdoor unit, appears on the remote controller but the heating operation is
disabled.
– 8 –
8-EN
Operations Manual
Automatic operation (auto changeover)
This function is available only for use in combination with a heat recovery
model outdoor unit. If this function is used with another model of outdoor
unit, “A” (Auto) appears on the remote controller but the automatic operation
is disabled.
Start
Timer operation
Use the wired remote controller for timer setting if it is also in use. ON
timer and OFF timer
1
3
2
SWING FAN
4
1 START/STOP button (
)
Press this button to start the air conditioner.
2 Mode select button (MODE)
Select A.
3 Temperature button ( )
Set the desired temperature.
4 Fan speed button (FAN)
Select one of
LOW , LOW+ ,
MED
, MED+
, HIGH
.
· The OPERATION lamp on the display panel of the indoor unit lights. The
operating mode is selected in accordance with the room temperature and
operation starts after approximately 3 minutes.
· If the “A” mode is uncomfortable, you can select the desired conditions
manually.
Stop
START/STOP button (
)
Press this button again to stop the air conditioner.
CAUTION
Disagreement in operation mode
If you select AUTOMATIC OPERATION in a model with no auto-changeover
(cooling/heating) control setting or if you select HEAT in a Cool Only model,
lamp
lights up and and lamps blink alternately with an alarm sound (pi, pi) from
the air conditioner due to disagreement in operation mode. Change the
operation mode with the MODE button on the wireless remote controller. This
disagreement indication cannot be deleted by the wired remote controller.
SWING FAN
FIX QUIET
Hi POWER
1
COMFORT
3
SLEEP
2
Setting TIMER
1 ON/OFF TIMER button ( or )
Press the ON or OFF TIMER buttons as required. · The previous timer setting is
displayed and
flashes along with ON/OFF timer display. Set the timer to the desired time.
Each press of the TIMER button changes the time in ten minute steps. Pressing
the TIMER button continually changes the time in one hour step.
2 SET button
Press the SET button to set the timer. The timer time is indicated and the
timer starts.
Cancelling TIMER
3 CLR button
Press the CLR button to cancel the timer setting.
CAUTION
· When you select the timer operation, the remote controller automatically
transmits the timer signal to the indoor unit at the specified time.
Therefore, keep the remote controller in a location where it can transmit the
signal to the indoor unit properly. Otherwise, the time lag of up to 15
minutes will occur.
· If you do not press the SET button within 30 seconds after setting the time,
the setting will be cancelled.
9-EN
– 9 –
Operations Manual
Once you select the timer operation mode, the settings are saved in the remote controller. Thereafter, the air conditioner will start operating under the same conditions when you simply press the ON/OFF button of the remote controller.
If the clock display is flashing, you cannot set the timer. Follow the
instructions in the section “SETTING THE
CLOCK” and then set the timer.
Combined timer (Setting both ON and OFF timers simultaneously)
OFF timer ON timer
(Operation Stop Operation)
This feature is useful when you want to stop the air conditioner after you go
to sleep, and start it again in the morning when you wake up or you return
home. Example: To stop the air conditioner and start it again next morning.
Operation
Operation again
Stop
ON timer OFF timer
(Stop Operation Stop)
You can use this setting to start the air conditioner when you wake up and
stop it when you leave the house. Example: To start the air conditioner next
morning and stop it.
Operation
Stop
Stop
Setting combined TIMER
1. Press the ON TIMER ON timer.
button to adjust the
2. Press the OFF TIMER OFF timer.
button to adjust the
3. Press the SET button.
· Either ON or OFF timer function which is closer to the current time, is
activated first.
· If the same time is set for both ON and OFF timers, no timer operation is
performed. Also, the air conditioner may stop operating.
Setting combined TIMER
1. Press the OFF TIMER timer.
button to adjust the OFF
2. Press the ON TIMER timer.
button to adjust the ON
3. Press the SET button.
Every day combined timer (setting both ON and OFF timer simultaneously and
activate every day.)
This feature is useful when you want to use combined timer at the same time
every day.
Setting combined TIMER
1. Press the ON TIMER ON timer.
button to adjust the
2. Press the OFF TIMER OFF timer.
button to adjust the
3. Press the SET button.
4. After step 3, an arrow mark ( or ) flashes for about 3 seconds and during this flashing, press the
SET button. · During the every day timer is activating, both arrows
( , ) are indicated.
Cancel the timer operation
Press the CLR button.
Clock display
During the TIMER operation (ON-OFF, OFF-ON, OFF timer) clock display is
disappeared so as to show the setting time. To see the present time, press SET
button briefly and the present time is displayed about 3 seconds.
– 10 –
10-EN
Operations Manual
High power operation
High power (Hi POWER)
· The Hi POWER (high power operation) mode automatically controls room
temperature, airflow and operation mode so that the room is quickly cooled in
summer and warmed in winter.
Quiet operation
· The QUIET mode provides quiet operating status by automatically setting the
fan speed to the lowest speed.
SWING FAN
FIX QUIET
Hi POWER
1
Setting Hi POWER mode
1 Hi POWER button
Press the Hi POWER button after starting any operation. At the same time, the
“Hi POWER” mark on the remote controller is indicated.
Cancelling Hi POWER mode
1 Hi POWER button
Press the Hi POWER button once again. At the same time, the “Hi POWER” mark on
the remote controller goes out.
CAUTION
· The Hi POWER mode cannot be activated in the DRY and FAN ONLY operation and
when the ON TIMER operation is reserved.
· Hi POWER mode is not available for group control. When Hi POWER is
transmitted to the Header indoor unit, the receiving sound is heard but the Hi
POWER mode will not be performed. Please cancel the Hi POWER mode.
SWING FAN
FIX QUIET
1
Hi POWER
Setting QUIET mode
1 QUIET button
Press the QUIET button after starting any operation. At the same time, the
mark is indicated.
Cancelling QUIET mode
1 QUIET button
Press the QUIET button once again.
At the same time, the controller disappears.
mark on the remote
CAUTION
The QUIET mode cannot be activated in the DRY operation.
NOTE
Under certain conditions, the quiet operation may not provide adequate cooling
or heating due to the feature of quietness.
11-EN
– 11 –
Operations Manual
Preset Operation
Set your preferred operation mode for future use. The setting is memorized by
the unit for future operation (except airflow direction).
CAUTION
The COMFORT SLEEP mode is not enabled in the DRY or FAN ONLY operation.
1
Select your preferred operation.
1 Press the PRESET button for 3 seconds to
memorize the setting. The P mark is displayed.
When you press this button next time, the memorized operation mode will be
enabled.
COMFORT SLEEP operation
COMFORT SLEEP mode is a OFF timer operation with automatic temperature and fan
speed adjustment.
NOTE
· For the cooling operation, the set temperature will automatically increase 1
degree/hour for 2 hours (maximum 2 degrees increase). For the heating
operation, the set temperature will decrease.
· During group control operation, the set temperature and the fan speed are
not automatically adjusted. Only off timer function is activated.
SWING FAN FIX QUIET
Hi POWER
COMFORT SLEEP
1
1 Press the COMFORT SLEEP button.
Select 1, 3, 5 or 9 hours for the OFF timer operation.
– 12 –
12-EN
Operations Manual
Adjusting airflow direction
· Adjust the airflow direction properly. Otherwise, it might cause discomfort
and make the room temperature uneven.
· Adjust the vertical airflow using the remote controller. · Adjust the
horizontal airflow manually.
To automatically swing the airflow direction Perform this function when the air conditioner is in operation.
Adjust the vertical airflow
The air conditioner automatically adjusts the vertical airflow direction in
accordance with the operating conditions when AUTO or A mode is selected.
Swing
To set the airflow direction you desire Perform this function when the air conditioner is in operation.
Swing
SWING FAN
1 FIX QUIET Hi POWER
1 SWING button
Press the SWING button on the remote controller. · To stop the function, press
the SWING button.
SWING FAN
1
FIX QUIET
Hi POWER
1 FIX button
Keep pressing or pressing briefly the FIX button on the remote controller to
move the louver in the desired direction. · In subsequent operations, the
vertical airflow is
automatically set in the direction to which you adjusted the louver using the
FIX button.
NOTE
Operating angle of vertical airflow louver will be different during cooling,
dry and heating operation.
CAUTION
· The FIX and SWING buttons will be disabled when the air conditioner is not
in operation (including when the ON timer is set).
· Do not operate the air conditioner for long hours with the airflow direction
set downward during the cooling or dry operation. Otherwise, condensation may
occur on the surface of the vertical airflow louver and cause dew dripping.
· Do not move the vertical airflow louver manually. Always use the FIX button.
If you move the louver manually, it may malfunction during operation. If the
louver malfunctions, stop the air conditioner once, and restart.
· When the air conditioner is started immediately after it was stopped, the
vertical airflow louver might not move for 10 seconds or so.
· Louver operation is limited when performing group control. (see page 6)
13-EN
– 13 –
Operations Manual
7 TEMPORARY OPERATION
TEMPORARY operation
This function is used to operate the unit temporarily in case you misplace the
wireless remote controller or its batteries are exhausted. · Push the
temporary operation button once (less than 3 seconds) to start the air
conditioner. · The last operation conducted with the wireless remote
controller will be performed. (When wireless remote
controller is not used, models with the auto-changeover (cooling/heating)
function perform “A” operation, and those without the function perform cooling
operation (set temperature: 24°C, fan: HIGH).)
I cannot find the remote controller
A temporary operation feature is
provided!
CAUTION
Continuous pressing of the temporary operation button for 10 seconds and above
will start the forced cooling operation. (This will impose burden on the air
conditioner. Do not perform this for the purposes other than test run.) In
this time all indicators of indoor unit go on.
– 14 –
14-EN
144 / 9 Moo 5, Bangkadi Industrial Park, Tivanon Road, Tambol Bangkadi, Amphur
Muang, Pathumthani 12000, Thailand
1130615201
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>