TrolMaster OA6-24 Aqua-X 24V Control Board Instructions

June 12, 2024
TrolMaster

TrolMaster OA6-24 Aqua-X 24V Control Board

TrolMaster-OA6-24-Aqua-X-24V-Control-Board-PRODUCT

Product Information

Thank you for purchasing our OA6-24 24V Control Board. The 24V Control Board is specially designed for the Aqua-X Irrigation Control System. It features 6 individual 24V outputs for solenoid valve control in the Aqua-X Control System. A solenoid valve is a basic component in automatic flow control in the irrigation system. With the use of 24V Control Board(s), the Aqua-X Irrigation Control System can manage up to 30 individually controlled 24V outputs (used to control solenoid valves) for multiple watering plans (by schedule or by recycle). With the massive control outputs, users can easily manage water delivery schedules for multiple nutrients, multiple rooms, and multiple zones.

Features

  • LED Power Indicator
  • Addressing Button
  • 6 Individually-Controlled 24V Outputs
  • Individual LED Indicator for Each Output
  • Double RJ12 Cable Sockets for Daisy Chain Connectivity

Product Usage Instructions

Connection to Aqua-X

Connect the 24V Control Board to the Aqua-X Controller.

Address Assignment

Once the 24V Control Board is successfully connected and the Aqua-X Controller is powered on, the LED indicator on the Control Board will keep flashing, indicating that the Control Board has not yet been assigned to the Aqua-X Controller.

24V Control Board Setting

Follow the steps below to set up the 24V Control Board:

  1. On the SETTING page, press the ENTER button to enter the 24V Control Board list page. The connected Control Boards will be shown page by page.
  2. Press the RIGHT button to select the desired 24V Control Board (A, B, C…) for the setting change.
  3. Once the Control Board is selected, press the ENTER button. The first output will be highlighted and blinking.
  4. Use the LEFT, RIGHT, UP or DOWN button to select the desired output (e.g., 24V A1).
  5. Press the ENTER button to confirm and enter the SETTING page of that output.
  6. On the SETTING page of the selected output, press the ENTER button. The tick icon on the “By schedule” option will be highlighted and blinking.
  7. Use the DOWN button to select “By recycle” if desired.
  8. Press the ENTER button to confirm and save the setting.

a. By Schedule

  • Similarly, you can change the “On at” and “Time” for other schedules (up to 12 lines) using the above process.

b. By Recycle

  • Similarly, you can change the “On time,” “Off time,” and “Times” accordingly.

Specifications

  • Refer to the product specifications for detailed information.

General Information

  • Please use TrolMaster’s components for better performance.
  • In the case of defects of the Control Board, the Control Board will either be replaced or required to be used with new or reconditioned products or parts by TrolMaster within a three-year warranty from the original date of purchase. For service, return the Control Board in good packaging to our agent with the original sales receipt.
  • Non-professionals should NOT open the cabinet to prevent electric shock or damage to the Control Board.

Warning

  • DO NOT allow the Control Board to be exposed to water or moisture.

Overview

  • Thank you for purchasing our OA6-24 24V Control Board
  • A 24V Control Board is specially designed for Aqua-X Irrigation Control System. It features 6 individual 24V outputs for the solenoid valve control in the Aqua-X Control System. A solenoid valve is a basic component in automatic flow control in the irrigation system
  • With the use of 24V Control Board(s), the Aqua-X Irrigation Control System could manage up to 30 individually controlled 24V outputs (used to control solenoid valves) for multiple watering plans (by schedule or by recycle). With the massive control outputs, user could manage water delivery schedules easily for multiple nutrients, multiple rooms and multiple zones.
  • If you have any questions, please contact us:
  • TrolMaster Agro Instruments Co.,Ltd.
  • 1112 Eagleridge Blvd Pueblo,CO 81008

Features

  • LED Power Indicator
  • Addressing Button
  • 6 Individually-Controlled 24V Outputs
  • Individual LED Indicator for Each Output
  • Double RJ12 Cable Sockets for Daisy Chain Connectivity TrolMaster-OA6-24-Aqua-X-24V-Control-Board-FIG-2

Operatimages/oa1.pngion Instructions

Connection to Aqua-X

  • Use a RJ12 Cable to connect the first 24V Control Board to the Aqua-X Controller. Plug the RJ12 cable connector into the 24V CONTROL port on the bottom of the Aqua-X Controller. Then plug the opposite RJ12 cable connector into the RJ12 cable socket on the either side of the first 24V Control Board. Use another RJ12 cable to connect the second 24V Control Board. Plug the RJ12 cable connector into the RJ12 cable socket on the opposite side of the first 24V Control Board. Then plug the opposite RJ12 cable connector into the RJ12 cable socket on the either side of the second 24V Control Board.
  • Other 24V Control Boards can be connected in series as above processes. However, the total connection number should not exceed 5 if the 24V Control Boards were used alone.

Address Assignment

  • When a 24V Control Board has been successfully connected, the Aqua-X Controller and powered on, the LED indicator on the Control Board will keep flashing which means that the Control Board has not yet been assigned to the Aqua-X Controller.
  • When the RJ12 cable is not correctly connected to the specific 24V CONTROL port or the 24V Control Board is not connected to the power supply or the 24V Control Board has not yet been assigned to the Aqua-X Controller, the LCD screen of the Aqua-X Controller will show “No 24V Board Online” on the setting page. Please make sure the RJ12 cable is correctly connected and power on the 24V Control Board. After power-on, the LED power indicator will keep flashing every second. Then press the ADDRESSING button on the 24V Control Board, the LCD screen of the Aqua-X Controller will display “24V Board A has been added”. The first connected Control Board will be marked as “A”, and the second one marked as “B”, the third one as “C”, and so on.

24V Control Board Setting

  • On the SETTING page, press the ENTER button to enter the 24V Control Board list page. The connected Control Board(s) will be shown page to page. User can press RIGHT button to select the 24V Control Board (A, B, C…) for the setting change.
  • When the Control Board is selected, press ENTER button and the 1st output will be highlighted and blinking. Press LEFT, RIGHT, UP or DOWN button to select the output such as 24V A1. Press ENTER button to confirm and enter the SETTING page of that output.
  • On the SETTING page of selected output such as 24V A1, press ENTER button and the tick icon on the “By schedule” will be highlighted and blinking. You can also press DOWN button to select “By recycle”. Press the ENTER button to confirm and save the setting.

a. By Schedule:

  • Once the “By schedule” setting is selected, the user can press ENTER button to activate the setting for the 1 line of total 12 lines of schedule. The Hour of “On at” time will be highlighted and blinking, which means that it’s ready for change. Users can press the UP or DOWN button to change the HOUR. Press the ENTER button and the MINUTE of “On at” will be highlighted and blinking, user press the UP or DOWN button to change the minute. Press the ENTER button and the MINUTE of “Time” will be highlighted and blinking, user can press the UP or DOWN button to change the minute. Press ENTER button and the SECOND will be highlighted and blinking, user can press the UP or DOWN button to change the second. Press the ENTER button and the tick symbol will be highlighted and blink. Finally, press the ENTER button to confirm and save the changes and the LCD screen will display “Setting saved”.
  • Similarly, the user can change the “On at” & “Time” for another schedule ( up to 12 lines) as above processes.

b. By recycle

  • Once the “By recycle” setting is selected, user can press UP or DOWN button to select ” Start”, “On time”, “Off time” & “Times” for change. Press ENTER button to activate the setting. For example, when “Start” selected, press “ENTER” button and the HOUR will be highlighted and blinking, user can press UP or DOWN button to change the hour. Press ENTER button and the MINUTE will be highlighted and blinking, press UP or DOWN button to change the minute. Finally, press ENTER button to confirm and save the change and the LCD screen will display ” Setting saved”
  • Similarly, user can change the “On time”, ” Off time” and “Times” accordingly.

SPECIFICATIONS

GENERAL INFORMATION

  • a ). Please use TrolMaster’s components for better performance
  • b ). In the case of defects of the Control Board, the Control Board will either be replaced or required using new or reconditioned products or parts by TrolMaster within a three-year warranty from the original date of purchase. For service, return the Control Board in good packaging to our agent with the original sale receipt. c ). Non-professionals DO NOT open the cabinet to prevent electric shock or damage to the Control Board.TrolMaster-OA6-24-Aqua-X-24V-Control-Board-FIG-11
  • WARNING : DO NOT allow the Control Board to be exposed to water or excessive heat. DO NOT open or attempt to repair or disassemble the Control Board, as there are no user-serviceable parts inside. Opening the controller will void the warranty.
  1. If the surface of the Control Board is dirty, wipe it with a dry towel.
  2. The Control Board is designed for indoor use only, it should be operated under natural ventilation conditions.
  3. For safety, it is necessary to connect the ground wire. If a short circuit did occur, the current would flow through the ground wire, causing a blown fuse or tripped circuit breaker.
  4. The Control Board should be positioned in a place that it’s easy to pull out when a fault occurs.