TrolMaster OM-8 Dry Contact Board Instruction Manual

June 12, 2024
TrolMaster

TrolMaster logo

TrolMaster OM-8 Dry Contact Board

TrolMaster OM-8 Dry Contact Board

Thank you for purchasing our OM-8 Dry Contact Module.
This dry contact board is specially designed for the Hydro-X Pro and Aqua-X Pro system. It has 8 individual electrical contacts, and allows up to 12 Amp current through each contact. The OM-8 should be mounted inside an electric control cabinet, and connected to a power supply between 100-240 VAC.

The OM-8 connects to the device port on the main controller using an RJ 12 cable. After the module is addressed and added to your main controller, the main controller will send signals to control up to 8 individual outputs on the OM-8.

Features

  1. LCD Display, Simple to set up and use
  2. Easy installation
  3. Overload protection on each of the 8 outputs@ 12-amps
  4. Each contact can be forced open or closed for a duration of 30 minutes

TrolMaster OM-8 Dry Contact Board 1

Installation

  1. Pull the 4 tabs outward to release the bracket from the unit, mount the bracket to an electric control cabinet. Place the unit back on the bracket and press the 4 tabs back in to lock the unit in place.
  2. Connect the unit to the power supply. (100-240 VAC)
  3. Connect the OM-8 to the Main controller using a RJ 12 cable.

NOTE: A small circuit break (e.g. 6A) is required for the OM-8 operation.

Instructions
1. Connect it to the main control system (Hydro-X Pro, Aqua-X Pro)
Use an RJ 12 cable to connect the main controller with the OM-8 as demonstrated below.

TrolMaster OM-8 Dry Contact Board 2

TrolMaster OM-8 Dry Contact Board 3

After the power supply is connected correctly, the LCD should display “Press Addressing Key to be addressed”, otherwise it will show “OFF LINE”

TrolMaster OM-8 Dry Contact Board 4

Addressing:
Press the addressing button to add the OM-8 to the main controller. The names of each of the outputs will be displayed differently on the OM-8, depending on which controller it’s connected to.

For Hydro-Pro:

For Aqua-X Pro:

WARNING: DO NOT allow the OM-8 Dry Contact Board to be exposed to water or excessive heat. DO NOT open or attempt to repair or disassemble the controller, as there are no user-serviceable parts inside. Opening the controller will void the warranty.

If the surface of OM-8 Dry Contact Board is dirty, wipe it with a dry towel. The OM-8 Dry Contact Board operates under natural ventilation conditions.
Where the circuit breaker is used as the disconnect device, the disconnect device shall remain readily operable.
This device must be mounted inside an electric control cabinet. The cabinet should be locked at all times. Beware of the risk of electric shock, do not open unless you are a professional technician.

NOTE: The electric control cabinet should not have any perforation.

SPECIFICATIONS

Input Voltage

Tension D’entree

| 100-240V~, 50/60Hz, 0.15A

100-240V~, 50/60Hz, 0.15A

---|---
Degree of Ingress Protection

Indice de protection

| IP20

IP20


Max Relay Amperage:

| 12A@250VAC

12A@30VDC


Working Environments:

| Temperature 32-104°F, Humiditys90%
Package Dimensions (LWH):| 255mmX135mmX95mm

ENVIRONMENTAL AND DISPOSAL CONCERNS:
THIS PRODUCT CONTAINS A BATTERY AND OTHER COMPONENTS WHICH MUST BE DISPOSED OF PROPERLY.

lt This symbol displayed on a product, its accessories, or its packaging indicates that this product may not be discarded as household waste.
Dispose of the equipment through a recycling center that handles electronics and electrical appliances. By disposing of the equipment in the proper and lawful way you will be helping to preven t possible damage to the environment and risk to public health.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TrolMaster User Manuals

Related Manuals