INSTALLATION
a) Pierce the bench (35mm), connect the inlet flexible hoses (2) to
the mixing faucet tightening them by hand (do not tighten by inappropriate
tools or in inappropriate ways) and insert them into the installation surface
hole.
b) Fasten faucet to installation surface using the fixing set (1).
c) Remove the chrome-plated botton (5) from the front of the lever
(4). Assemble the lever (4) onto the square top of the mixing
cartridge (3) and tighten its screw (6). Fix the botton (5) on its
seat taking care to place the blue and red indicators in the right positions.
d) Connect the left inlet flexible hose with hot water and the right one
with cold water, maintaining minimum bend radius (30mm).
The installer has the responsibility to ensure that the installation is done
according to European Norm EN 1717. In case it is not mounted on the main
water supply system, it is highly recommended to install a water softener or
filter, because limestone deposits and impurities in the water may eventually
cause clogging and damage the faucet’s mixing cartridge.
e) Test the right working of the faucet before starting using it. Test
the faucet with lever up (open), down (close), up left (hot water) up right
(cold water). If the supply of cold / hot water is reversed, reverse the
connection of the inlet flexible hoses.
Operating parameters
Minimum static pressure: > 0,1 Mpa (1 bar)
Maximum water temperature and pressure: < 65° and < 1 Mpa static
Recommended water temperature and pressure: < 60° and < 0,5 Mpa The mixing
cartridge is approved for operation at a maximum water temperature of 65°C.
Operating with hotter water than specified will cause serious damage to the
mixing cartridge
USE
- Do not move the swivel nozzle and lever violently in order to prevent possible damages to mixing cartridge
- Keep the faucet’s surfaces clean and dry using a soft cloth, in order to prevent limestone or corrosion
MAINTENANCE and CLEANING
- Before cleaning make sure faucet surface is of room temperature
- Do not use aggressive and / or corrosive detergents and / or cleaning pads
- After cleaning with soft detergent rinse immediately with cold water
- Remove the aerator often and keep it clean with suitable solvents (not corrosive) and water