VIMAR 02082.AB CALL-WAY Voice Unit Module User Manual

June 12, 2024
VIMAR

VIMAR 02082.AB CALL-WAY Voice Unit Module

VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-PRODUCT

Voice unit module to activate voice communication, activate and adjust the music channel and announcements, equipped with a flat cable for connecting to the display module, complete with single base for surface mounting, white. The device, installed in the single room and powered directly by the display module 02081.AB, enables hands-free communication between patient and nurse and between nurses; via the voice unit module it is moreover possible to make room, ward and general announcements and broadcast a music channel with the possibility of adjusting the listening volume. The device is equipped with 4 front buttons to activate voice communication, switch on, off and adjust the volume (decrease and increase) of the music channel. It is connected to the display module 02081.AB by means of the flat cable supplied.

CHARACTERISTICS.

  • Rated supply voltage (from display module 02081): 5 V d.c. ± 5%.
  • Absorption : 5 mA.
  • Speaker output power : 0.15 W/16 Ω.
  • Speakers: 2 x 8 Ω -250 mW in series.
  • Operating temperature: +5 °C – +40 °C (indoor).

INSTALLATION.

Vertical installation with double base:

  • to carry out semi-recessed mounting on light walls, on boxes with 60 mm distance between centres or on 3-gang boxes, use the double base;
  • connect the flat cable to the voice unit module 02082.AB and hook it onto the double base 02083 taking care to lay out the cable;
  • before hooking the display module 02081.AB onto the double base 02083, connect the extractable terminals 02085 (bus, inputs/outputs, + OUT and -).

Vertical/horizontal installation with single base:

  • use the single base to perform the installation;
  • connect the flat cable to the voice unit module 02082.AB and hook it onto the single base taking care to lay out the cable;
  • before hooking the display module 02081.AB onto its single base, connect the extractable terminals 02085 (bus, inputs/outputs, + OUT and -).

Horizontal installation

Vertical installation

FRONT VIEW

  • Button E: Switching music channel on/off and controlling voice direction (press to speak).
  • Button F: Decrease volume (only music channel).
  • Button G: Increase volume (only music channel).
  • Button H: Voice communication.

CONNECTIONS

VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-FIG-1
\(4\)VIMAR0-02082-AB-CALL-WAY-Voice-Unit-
Module-FIG-1 \(5\)

INSTALLATION WITH TWIN BASIS ON BRICK WALLS

INSTALLATION ON 3-MODULE FLUSH-MOUNTING BOXESVIMAR0-02082-AB-CALL-WAY-Voice-
Unit-Module-FIG-1 \(6\)

INSTALLATION ON ROUND FLUSH-MOUNTING BOX AND BASE FIXING WITH PLUGS AT TOPS.VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-FIG-1
\(7\)

HORIZONTAL INSTALLATION ON 2 RECTANGULAR FLUSH-MOUNTING BOXES, SIZE 3 MODULES, WITH COUPLING JOINTS (V71563).VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-
FIG-1 \(8\)

VERTICAL INSTALLATION ON 2 RECTANGULAR FLUSH-MOUNTING BOXES, SIZE 3 MODULES, WITH COUPLING JOINTS (V71563).VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-
FIG-1 \(9\)

VERTICAL INSTALLATION WITH DOUBLE BASE ON LIGHT WALLS.

INSTALLATION ON ROUND FLUSH-MOUNTING BOXES WITH FIXING CENTRE DISTANCE 60 mm.VIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-FIG-1
\(10\)

INSTALLATION ON 3-MODULE FLUSH-MOUNTING BOXESVIMAR0-02082-AB-CALL-WAY-Voice-
Unit-Module-FIG-1 \(11\)

UNHOOKING THE DISPLAY MODULE AND VOICE UNIT MODULEVIMAR0-02082-AB-CALL-WAY-
Voice-Unit-Module-FIG-1 \(12\)

  1. Insert and gently push a small Phillips screwdriver into the hole.
  2. Press lightly to unhook one side of the module.
  3. Insert and gently push the screwdriver into the second hole.
  4. Press lightly to unhook the other side of the module.
  5. Extract the module.

MODULE ASSEMBLY

  1. Connect the voice unit module.
  2. Arrange the connection cables inside the box.
  3. Connect the display module.
  4. UNHOOKING THE DISPLAY MODULEVIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-FIG-1 \(14\)
  5. Extract the display module.

1, 2, 3, 4. Carry out the same operations illustrated for unhooking the voice unit module.

UNHOOKING THE VOICE UNIT MODULE

VIMAR0-02082-AB-CALL-WAY-Voice-Unit-
Module-FIG-1 \(15\)

  1. Insert and gently push a small Phillips screwdriver into the hole.
  2. Press lightly to unhook one side of the module.
  3. Insert and gently push the screwdriver into the second hole.
  4. Press lightly to unhook the other side of the module.
  5. Extract the module.

The voice unit module is used to perform the following functions:

Voice communication

Systems equipped with speaker modules enable remote communication between the rooms which have been provided with nurse present signaling (green button on the display module) or between the supervisor and the room which has been provided with presence signalling. The volume level of the voice unit cannot be changed from the terminal.

  • Pressing button H once only (fully illuminated) starts hands-free communication with the terminal from which the call is made; on pressing button H a second time (minimum illumination) the voice communication is interrupted.
  • If there is more than one call, with button A of the display module 02081.AB, it is possible to scroll through the list of these calls and select the one you want to answer.
  • Button E lights up fully when a call is made to the room (for example via VOX) or when there is voice communication; in the case of voice communication piloted by the nurse, lights up to indicate you can speak (voice unit module in transmission).
  • The “direction” in which the communication is made is indicated by the same button (button E on = speak; button E off = listen).

The mode with which this communication is managed (full duplex/half duplex) is established by the device that triggers it:

  • telephone coupler always full duplex;
  • voice depending on the chosen configuration. In the latter mode, the half-duplex switching can take place in two ways:
  • Hands-free, where the “direction” of the communication is established by the tone of voice; the exchange is made when the voice unit module recognizes a higher sound level of one speaker rather than the other. This type of solution is used in rooms that are not very noisy.
  • Push to talk, where the communication exchange between the speakers takes place by pressing the button E (press to speak, release to listen) by the health personnel present in the control room or in a room where assistance is being given; the switching is controlled by the terminal that requested the voice unit connection. This type of application is used in noisy rooms.

Music transmission

Connecting the system to an audio source, when the system contains a phone coupler, the voice unit modules enable transmitting a music channel.

  • Pressing button E switches the music transmission on and off (the button is illuminated);
  • pressing button F lowers the volume;
  • pressing button G increases the volume.
  • ButtonsVIMAR0-02082-AB-CALL-WAY-Voice-Unit-Module-FIG-1 \(21\) and H are backlit with a red light for location in the dark.
  • When the voice or music channel is activated, the display will show the symbol with the set volume level

INSTALLATION RULES

Installation should be carried out by qualified staff in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed. Recommended installation height: from 1.5 m to 1.7 m.

CONFORMITY.

EMC directive. Standards EN 60950-1, EN 61000-6-1, EN 61000-6-3. REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE – Information for users
If the crossed-out bin symbol appears on the equipment or packaging, this means the product must not be included with other general waste at the end of its working life. The user must take the worn product to a sorted waste center, or return it to the retailer when purchasing a new one. Products for disposal can be consigned free of charge (without any new purchase obligation) to retailers with a sales area of at least 400 m2 if they measure less than 25 cm. An efficient sorted waste collection for the environmentally friendly disposal of the used device, or its subsequent recycling, helps avoid the potential negative effects on the environment and people’s health and encourages the re-use and/or recycling of the construction materials.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals