VIMAR 03835 BY-ALARM PLUS Detector Movim.RF Superf Instruction Manual

June 12, 2024
VIMAR

BY-ALARM PLUS
03835

 03835 BY-ALARM PLUS Detector Movim.RF Superf

By-alarm Plus passive infrared + microwave double detector technology, 868 MHz radio frequency connection, masking detection, power supply with CR17450 3V lithium battery included, surface mounting, white.
The dual technology sensor incorporates a microwave sensor and an infrared sensor and is able to signal people or animals passing through its area of coverage. The dual technology enables making the sensor insensitive to the most common causes of false alarms. The sensor functions in “AND” mode, this means that, when either sensor detects motion in the area of coverage it remains on pre-alarm awaiting confirmation from the other sensor as well. Once this condition occurs the device sends the signal to the control unit.

BATTERIES

The detector is powered by a CR17450 3 V lithium battery. To proceed with battery replacement, simply open up the body of the device and then replace the battery, paying attention to the correct insertion, with the polarities indicated.
When replacing the battery, it is good practice to press the configuration push button to be sure of synchronising the device with the receiver via radio.
CAUTION! Risk of explosion if the battery is replaced with the incorrect type

INSTALLATION

  1. Choose a suitable location for installation.
  2. Undo the screw, open the cover and remove it from the base.
  3. Undo the screw and remove the electronic board from its seat.
  4.  Open the through holes for the fixing screws.
  5. Hold the base where it will be fastened and mark the fixing points.
  6. Fasten the base with the fixing screws.
  7.  Insert the battery with the correct polarity.
  8. Add the device and enter the QR code in the By-alarm Plus Manager software to configure it.
  9. Refit the electronic board in its seat.
  10. Fit the front cover and tighten the fixing screws.
  11. Carry out the appropriate programming and set the sensitivities.

OPERATION

If someone is moving in the space covered by the detector, the alarm signal is activated and the LEDs corresponding to the sensors that detected the movement turn on; in this case, the red LED lights to indicate that the alarm signal was sent and has been received by the control unit.
The detector sensitivity can be set during configuration, depending on the environment and the position where it is installed. Varying the sensitivity reduces the range and reduces its ability to detect small heat/temperature variations.
LED indications
The LED lights with different colours according to the status:

  • red = alarm detected
  • yellow = infrared activated
  • green = microwave activated

Anti-tamper
The detector is protected against tampering by:

  • a contact on the electronic board;
  • an inertial sensor that detects detector position and tilt variations.

Anti-masking
When configured appropriately, the microwave module provides anti-masking protection. If the front of the detector is covered with reflective or ferrous material, a “masking” signal is generated and will only be reset after the covering material has been removed. The distance between the covering material and detector required to create masking depends on the material, and may be in the range 0 to 30 cm; ferrous materials are detected closer than reflective materials. The signal is generated within about 30 s of covering the detector; it is reset about 5 s after removing the material. The alarm is inhibited for about 3 minutes after being transmitted.
FRONT VIEW

VIMAR 03835 BY-ALARM PLUS Detector Movim.RF Superf - FRONT
VIEW

A: Plastic device cover
B: Red indicator LED
C: Lens
D: Plastic base
E: Seats for cover closing tabs
F: Seats for fixing screws
G: Cover fixing screw
H: Battery positive +
I: Battery negative –
J: Anti-tamper contact
K: Configuration push button
L: Infrared sensor (PIR)
M: Microwave sensor (MW)

WARNING: Dispose of batteries in the specific separate collection bins.

CONFIGURATION

Refer to the By-Alarm Plus system installation manual and the By-Alarm Plus Manager software manual for all the details.

INSTALLATION RULES

  • Installation and configuration must be carried out by qualified personnel in compliance with the current regulations regarding the installation of electrical equipment in the country where the products are installed.
  • Install the device at a height of 2 to 2.4 m.
  • The fixing screws are part of the anti-removal device, and so they are essential to ensure that it operates correctly.
  • Take great care to avoid drilling into water pipes, gas pipes, electrical conduits, etc. during installation.
  • Do not install the detector near the following disturbance sources: reflective surfaces, direct air flows, draughts, fans, windows, steam sources, oil vapours, infrared sources, electrical lines, neon lights and objects that can cause temperature variations, such as stoves, refrigerators and ovens (see the INSTALLATION RULES figure).
  • Do not use this product in areas with sudden temperature changes.
  • Do not install more than one detector in the same room, or two detectors in different rooms but less than 2m from each other.
  • Do not obscure the field of view of the detector, not even partially.
  • The LEDs must be above the lens.
  • Do not touch the sensor surface as doing so may cause it to malfunction. Clean the sensor surface with a soft cloth if necessary.

CHARACTERISTICS

  • Power supply: 3 V CR17450 lithium battery included

  • “Low battery” signal voltage: < 2.4 V

  • Consumption:
    – 50 µA in standby
    – 30 mA max during operation

  • Sensor type: Dual digital PIR and microwave module

  • Detection method: Infrared emission + doppler effect

  • Countable alarm pulses: 1 to 2

  • Minimum signalling duration: 5 s

  • Detection distance: 10 m max

  • Detection angle: 90°

  • Frequency range: 868 MHz

  • RF transmission power: < 25 mW (14dBm)

  • Microwave:
    – Frequency range: 24.0 – 24.25 GHz
    – Max RF output power: 31.62 mW e.i.r.p. (15 dBm)

  • Communication type: bidirectional

  • Modulation: GFSK

  •  Average battery life: 3 years

  • Low battery warning: on the keypad and in the control unit

  • 1 configuration push button

  • Alarm indicator LED

  • Operating temperature: -10 to +40 °C

  •  Relative humidity: ≤ 93% non-condensing

  • Safety class: 2

  • Environment class: II

  • Dimensions (W x H x D): 120 x 60 x 48 mm

  • Weight: 100 g

REGULATORY COMPLIANCE.

RED directive. RoHS directive.
Standards EN 62368-1, EN 50130-4, EN 50130-5, EN 55032, EN 50131-2-6, EN 301 489-3, EN 300 220-2, EN 62479, EN IEC 63000.
Vimar SpA declares that the radio equipment complies with Directive 2014/53/EU. The full textof the EU declaration of conformity is on the product sheet available on the following website: www.vimar.com.
REACH (EU) Regulation no. 1907/2006 – Art.33. The product may contain traces of lead.
WEEE – User information
The crossed bin symbol on the appliance or on its packaging indicates that the product at the end of its life must be collected separately from other waste. The user must therefore hand the equipment at the end of its life cycle over to the appropriate municipal
centres for the differentiated collection of electrical and electronic waste. As an alternative to independent management, you can deliver the equipment you want to dispose of free of charge to the distributor when purchasing a new appliance of an equivalent type.
You can also deliver electronic products to be disposed of that are smaller than 25 cm for free, with no obligation to purchase, to electronics distributors with a sales  area of at least 400m 2 . Proper sorted waste collection for subsequent recycling, processing and  nvironmentally conscious disposal of the old equipment helps to prevent any possible negative impact on the environment and human health while promoting the practice of reusing and/ or recycling materials used in manufacture.VIMAR 03835 BY-ALARM PLUS
Detector Movim.RF Superf - INSTALLATION RULESVIMAR 03835 BY-ALARM PLUS Detector Movim.RF Superf -
COVER DIAGRAMS

49401657A0 01 2212

Viale Vicenza, 14
36063 Marostica VI – Italy
www.vimar.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals