Product Information

Product Name: IBS Advanced Round Insulated Braided Conductor
Catalog Number: IBSADV120-530
Product Description: The IBS Advanced Round Insulated Braided Conductor is a low voltage connector made from high-quality electrolytic copper wire. It is designed to provide maximum flexibility and durability for power connections to electrical devices. The insulation is made from a high- resistance, low smoke, halogen-free, and flame retardant thermoplastic material.
Manufacturing: This product is manufactured in an ISO 9001 certified automated facility.

Features:

  • Round shape for more compact power connections
  • Pre-punched palms for easy and fast connections
  • No lugs required, eliminating faulty connections due to vibration or fatigue
  • Low smoke opacity in accordance with IEC 61034-2 and UL 2885
  • Does not generate corrosive gases
  • Improves visibility for emergency situations
  • Reduces environmental impact

Certifications:

  • No certifications are mentioned in the provided text.

Product Usage Instructions

  1. Ensure that the power source is turned off before making any connections.
  2. Identify the pre-punched palms on the round IBS Advanced connector.
  3. Match the corresponding electrical devices with the appropriate pre-punched palms.
  4. Insert the electrical device connectors into the pre-punched palms until they are securely connected.
  5. Repeat the process for all required connections.
  6. Once all connections are made, ensure that they are secure and properly aligned.
  7. After confirming the connections, you can turn on the power source.
  8. If there are any issues or concerns, refer to the nVent product instruction sheets available at www.nvent.com or contact your nVent customer service representative.

Warning: Please follow all nVent’s product instruction sheets and training materials for proper installation and usage to avoid product malfunction, property damage, bodily injury, and warranty voidance.

Contact Information:

  • Europe Netherlands: +31 800-0200135
  • France: +33 800 901 793
  • Europe Germany: 800 1890272
  • Other Countries: +31 13 5835404
  • APAC Shanghai: +86 21 2412 1618/19
  • Sydney: +61 2 9751 8500

Note : The information provided is based on the given text-extract from the user manual. For detailed instructions and additional information, please refer to the complete user manual or contact nVent customer service.
Disclaimer : This response is provided as a general guide and should not replace professional advice or specific instructions from the manufacturer.
Source : Product information and instructions extracted from the user manual.

CATALOG NUMBER

  • IBS Advanced Round Insulated Braided Conductor, Halogen Free are the ideal ready-to-install flexible wire replacement solution. Round IBS Advanced connect to the terminals of an electrical device without the need for additional accessories, such as angular connectors, spreaders, ring terminal connectors or extenders. Round IBS Advanced are available in cross sections of 120, 185 and 240 mm²
    (236.82, 365.10, and 473.65 kcmil), lengths from 330 to 1,030 mm (9.06″ to 40.55″), and amperages ranging from 420 to 630 A.

  • Manufactured in an ISO 9001 certified automated facility, round IBS Advanced is formed by weaving high-quality electrolytic copper wire to form a durable low voltage connector with maximum flexibility that allows for more compact power connections to electrical devices. The round IBS Advanced allows users to reduce the total size and weight of the installation, improving both design flexibility and assembly aesthetics.

  • The round IBS Advanced features pre-punched palms that are ready to connect out of the box. There are no lugs to purchase or install, making connections simpler and faster and eliminating faulty connections due to vibration or fatigue.

  • The advanced technology insulation is a high-resistance low smoke, halogen-free and flame retardant thermoplastic.

  • Round IBS Advanced does not generate corrosive gases and produces a relatively low smoke opacity in accordance with IEC 61034-2 and UL 2885. The low smoke characteristic improves the visibility conditions for people to be able to easily locate the emergency exit and also allows rescue workers to better assess an emergency situation. Round IBS Advanced means greater safety for individuals, less damage for your electrical equipment and less environmental impact.

  • The halogen–free feature enables a reduction in the quantity of toxic smoke. Round IBS Advanced does not contain any halogens, according to IEC 60754-1 and UL 2885, minimizing toxicity and making it the ideal product for use in enclosed spaces such as data centers, rail, and public facilities such as hospitals and schools. This also facilitates the use of round IBS Advanced in specific applications such as submarines, switchboards and other enclosed environments that require a low emissions solution.

  • In addition to the above features, round IBS Advanced is also compliant with the UL 94-V0 testing standard and Glow wire test 960 °C. The flame retardant portion of the test illustrates the self-extinguish feature.

  • This superior feature of round IBS Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In case of fire, round IBS Advanced generates a limited quantity of smoke that is less damaging to your electrical equipment.

CERTIFICATIONS

nVent-ERIFLEX-EFX-534516-IBS-Advanced-Round-Insulated-
Braided-Conductor-fig- \(3\)

FEATURES

  • Resistant to vibration, improving reliability and performance
  • Insulated by high-resistance, halogen free, flame retardant and low smoke material
  • Tinned copper provides superior corrosion resistance
  • Improves assembly flexibility and aesthetics
  • Quick and easy installation
  • No additional cutting, stripping, crimping and punching needed
  • Conforms to NF EN 45545 obtaining an HL3 classification for chapters R22 and R23
  • Small wire diameter provides maximum flexibility
  • Dramatically smaller and more flexible than comparable cable based on ampacity
  • Better power density than cable with lower skin effect ratio
  • Reduces total installation cost
  • RoHS compliant

PRODUCT ATTRIBUTES

  • Article Number: 534516
  • Typical Application Current Rating: 400 A
  • Material: Copper;Thermoplastic Elastomer
  • Finish: Tinned
  • Dielectric Strength: 20 kV/mm
  • Low Smoke Rating: IEC® 61034-2;ISO 5659-2;UL® 2885
  • UV Resistance Rating: UL® 854;UL® 2556
  • Halogen Free Rating: UL® 2885;IEC® 60754-1;IEC® 62821-1
  • Flammability Rating: UL® 94V-0
  • Insulation Elongation: 500 %
  • Insulation Thickness: 0.070″
  • Max Working Voltage, IEC/UL 758: 1,000 VAC;1,500 VDC
  • Max Working Voltage, UL 67: 600 VAC/DC
  • Working Temperature: -58 to 239 °F
  • Wire Diameter: 0.006″
  • Certification Details: UL® 67;UL® 758
  • Complies With: IEC® 60439.1;IEC® 60695-2-11 (Glow Wire Test 960 °C);IEC® 61439.1;IEC® 61439.1 Class II
  • Cross Section: 236.820 kcmil
  • Conductor Width: 0.94″
  • Conductor Thickness: 0.39″
  • Length: 20.870″
  • A: 0.470″
  • Diameter: 1.060″
  • Hole Size: 0.410″
  • Unit Weight: 1.760 lb

ADDITIONAL PRODUCT DETAILS

ΔT = Temperature of conductors – Internal temperature of panel.

This table indicates the temperature rise produced by chosen current in the given section. This calculation does not take
into account the heat dissipation from the switch gear.
Distance between supports must not exceed 630 mm (17.8″) according to IEC 61439-1.

DIAGRAMS

nVent-ERIFLEX-EFX-534516-IBS-Advanced-Round-Insulated-Braided-
Conductor-fig- \(4\)

WARNING
nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty.

North America
+1.800.753.9221
Option 1 – Customer Care
Option 2 – Technical Support

Europe
Netherlands:
+31 800-0200135
France:
+33 800 901 793

Europe
Germany:
800 1890272
Other Countries:
+31 13 5835404

APAC
Shanghai:
+ 86 21 2412 1618/19
Sydney:
+61 2 9751 8500

nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
2022 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners. nVent reserves the right to change specifications without notice.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

nVent ERIFLEX User Manuals

Related Manuals