IBSB ADVANCED INSULATED BRAIDED CONDUCTOR, 160 A, 0.47″ X 0.11″ X 20.87″
CATALOG NUMBER
IBSBADV25-530
IBSBADV25-530 IBSB Advanced Insulated Braided Conductor
IBS/IBSB Advanced Insulated Braided Conductor, Halogen Free is the ideal
ready-to-install flexible wire replacement solution that is specifically
designed for connections to all molded case circuit breakers, including the
most compact breakers on the market. IBS/IBSB Advanced connects to the front
access terminals of the breakers without any additional accessories, such as
angular connectors, preaders, ring terminal connectors or extenders. IBS/IBSB
Advanced is available in cross sections of 25 to 240 mm² (49.34 to 273.65
kcmil), lengths from 230 to 1,030 mm (9.06″ to 40.55″), and 80 to 700 A.
Manufactured in an ISO 9001 certified automated facility, IBS/IBSB Advanced is
formed by weaving high-quality electrolytic copper wire to form a durable low
voltage connector with maximum flexibility which allows for more compact
power connections to circuit breakers. The IBS/IBSB Advanced allows users to
reduce the total size and weight of the installation, improving both design
flexibility and assembly aesthetics.
The unique manufacturing process of integral pre-punched palms make IBS/IBSB
Advanced ready to connect out of the box. There are no lugs to purchase or
install, making connections simpler and faster and eliminates faulty
connections due to vibration or fatigue.
IBS/IBSB Advanced is compatible with all major brand molded case circuit
breakers.
The advanced technology insulation is a high-resistance low smoke, halogen-
free and flame retardant thermoplastic.
IBS/IBSB Advanced does not generate corrosive gases and produces a relatively
low smoke opacity in accordance with IEC 61034-2 and UL 2885. The low smoke
characteristic improves visibility conditions for people to be able to easily
locate the emergency exit and also allows rescue workers to better assess an
emergency situation. IBS/IBSB Advanced means greater safety for individuals,
less damage for your electrical equipment and less environmental impact.
The halogen–free feature enables a reduction in the quantity of toxic smoke.
IBS/IBSB Advanced does not contain any halogens, according to IEC 60754-1 and
UL 2885, minimizing toxicity and making it the ideal product for use in
enclosed spaces such as data centers, rail, and public facilities such as
hospitals and schools. This also facilitates the use of IBS/IBSB Advanced in
specific applications such as submarines, switchboards and other enclosed
environments that require a low emissions solution.
In addition to the above features, IBS/IBSB Advanced is compliant with the UL
94-V0 testing standard and glow wire test 960 °C. The flame retardant portion
of the test illustrates the self-extinguish feature. This superior feature of
IBS/IBSB Advanced is also shown by the Limiting Oxygen Index (LOI) at 30%. In
case of fire, IBS/IBSB Advanced generates a limited quantity of smoke that is
less damaging to your electrical equipment.
CERTIFICATIONS
FEATURES
Suitable for all main molded case circuit breakers
Resistant to vibration, improving reliability and performance
Insulated by high-resistance, halogen free, flame retardant and low smoke
material
Tinned copper provides superior corrosion resistance
Improves assembly flexibility and aesthetics
Quick and easy installation
No additional cutting, stripping, crimping and punching needed
Integral palm without lugs or terminals reduces material and assembly weight
Conforms to NF EN 45545 obtaining an HL3 classification for chapters R22 and
R23
DNV GL® and Bureau Veritas certified for marine and offshore applications
Small wire diameter provides maximum flexibility
Dramatically smaller and more flexible than comparable cable based on ampacity
Better power density than cable with lower skin effect ratio
Reduces total installation cost
RoHS compliant
Tinned copper allows for copper or aluminum conductor connections
PRODUCT ATTRIBUTES
Article Number: 534403
Typical Application Current Rating: 160 A
Peak Short Circuit Current (Ipk): 14 kA
Finish: Tinned
Material: Copper;Thermoplastic Elastomer
Dielectric Strength: 20 kV/mm
Low Smoke Rating: IEC® 61034-2;ISO 5659-2;UL® 2885
UV Resistance Rating: UL® 854;UL® 2556
Halogen Free Rating: UL® 2885;IEC® 60754-1;IEC® 62821-1
Flammability Rating: UL® 94V-0
Insulation Elongation: 500 %
Insulation Thickness: 0.070″
Max Working Voltage, IEC/UL 758: 1,000 VAC;1,500 VDC
Max Working Voltage, UL 67: 600 VAC/DC
Working Temperature: -58 to 239 °F
Wire Diameter: 0.006″
Complies With: IEC® 60439.1;IEC® 60695-2-11 (Glow Wire Test 960 °C);IEC®
61439.1;IEC® 61439.1 Class II
Certification Details: UL® 67;UL® 758
Cross Section: 49.340 kcmil
Conductor Width: 0.47″
Conductor Thickness: 0.11″
Length: 20.870″
D: 0.350″
C: 0.710″
B: 0.256″
A: 0.256″
Hole Size 1: 0.260″
Hole Size 2: 0.260″
Unit Weight: 0.400 lb
ADDITIONAL PRODUCT DETAILS
∆T = Temperature of conductors – Internal temperature of panel.
This table indicates the temperature rise produced by chosen current in the
given section. This calculation does not take into account the heat
dissipation from the switch gear.
IBSB Advanced Insulated Braided Conductor with a cross section of 240 mm²
(473.65 kcmil) is constructed of red copper strands with tinned palms.
Distance between supports must not exceed 630 mm (17.8″) according to IEC
61439-1.
DIAGRAMS
Circuit Breaker Compatibility
WARNING
nVent products shall be installed and used only as indicated in nVent’s
product instruction sheets and training materials. Instruction sheets are
available at www.nvent.com and from your nVent customer service
representative. Improper installation, misuse, misapplication or other failure
to completely follow nVent’s instructions and warnings may cause product
malfunction, property damage, serious bodily injury and death and/or void your
warranty.
North America
+1.800.753.9221
Option 1 – Customer Care
Option 2 – Technical Support| Europe
Netherlands:
+31 800-0200135
France:
+33 800 901 793| Europe
Germany:
800 1890272
Other Countries:
+31 13 5835404| APAC
Shanghai:
+ 86 21 2412 1618/19
Sydney:
+61 2 9751 8500
---|---|---|---
Our powerful portfolio of brands:
nVent.com
CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER
© 2022 nVent. All nVent marks and logos are owned or licensed by nVent
Services GmbH or its affiliates. All other trademarks are the property of
their respective owners.
nVent reserves the right to change specifications without notice.
References
- Building a more Sustainable and Electrified World | nVent
- Building a more Sustainable and Electrified World | nVent