Simply Retrofits 3CCT LED Multi Wattage Wall Pack Installation Guide

June 13, 2024
Simply Retrofits

**Simply Retrofits 3CCT LED Multi Wattage Wall Pack Installation Guide

**

Warning:

  1. Do not use the electric generator to test the LED lamp;
  2. This luminaire must be installed in accordance with your local electrical codes and requirements;
  3. Do not install the luminaire in rainy days, to avoid lightning stroke and damage to luminaire.

Installation notice:

  1. This luminaire must be installed by qualified electrician to avoid electric shock and fire accident;
  2. Wear gloves before installation in order to avoid injury;
  3. Tum off the power immediately when there is smoke and fire during installation, inform professionals to overhaul;
  4. This luminaire is suitable for outdoor use.

Installation

Step 1: Loosen the screws on the side of the radiator with an Allen wrench, and rotate the radiator to 90 degrees(Figure 1 & Figure 2);
Installation

Step 2: Use a screwdriver to remove the screws on the driver box cover and separate the driver box from the radiator(Figure 3 & Figure 4);
Installation

Step 3: Drill an installation holes at the bottom of light, paste the EVA mat(Figure 5 & Figure 6);
Installation

Step 4: Drill holes on the wall according to the locating plate(Figure 7);

Step 5: Fix rubber plugs into holes (Figure 8);
Installation

Step 6: Align the holes on the lamp base with the holes on the wall, and tighten the screws(Figure 9);

Step 7: Fasten the radiator to the driver box and connect the wires properly ((Figure 10 & Figure 11);
Installation

Step 8: Well organize the line and tighten the screws of the lamp base (Figure 12 & Figure 13).
Installation

Standard wire

L/Iive wire: Black\Brown:
N/null wire:White\Blue;
Ground wire: Green\Yellow-green.

Note: To meet the requirements of DLC certification, lamps are limited to the same side of the light-emitting use, not in different directions of irradiation use (as shown below)

Standard wire

CCT & Wattage adjustment Instruction

  1. After the fixture is fixed(Step 9), adjust the CCT via a controlling switch as per your Step 1: Loosen the screws on the side of the radiator with an Allen wrench, and rotate the radiator to demand, with 3000K/ 4000K/ S000K optional, as shown in below picture; 90 degrees(Figure 1 & Figure 2);
  2. After the fixture is fixed(Step 9), adjust the wattage via a controlling knob as per your demand, with 3 settings optional, as shown in below picture;

CCT & Wattage adjustment Instruction

Warning/Advertisement

MIN 90°C SUPPLY CONDUCTORS

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED