legrand 412173 DRIVIA Connected Dry-Contact Contactor Instructions

June 13, 2024
Legrand

Connected Dry-Contact
4 121 73 – 1 991 23
Instructions

412173 DRIVIA Connected Dry-Contact Contactor

Requires the installation of a:

legrand 412173 DRIVIA Connected Dry-Contact Contactor -
Contactor

Composition

legrand 412173 DRIVIA Connected Dry-Contact Contactor -
Composition

CE Directive , Compliant with the following European directive:
Low voltage directive (LVD) 2014/35/UE Electromagnetic compatibility (CEM) n° 2014/30/UE

| Supply N – L| Contact 1 – 2 Monostable| | | | Measure|

Shedding

---|---|---|---|---|---|---|---
| |
-5°C +45°C| 100-240V~ 50 / 60Hz| 30VDC Max 250VAC Max|  0,01A Min 2A Max| 2,4 to 2,4835Ghz
<100 mW| Silent < 10dB| Planning| 80A Max| Connected shedding
compatible

Imperative security precaution

The instructions for installation and use must be strictly observed in order to avoid the risk of electric shock or fire.

  1. Preparation, connectionlegrand 412173 DRIVIA Connected Dry-Contact Contactor - Composition1 Wiring examples
    Control of any type of device from 12 to 30V DC via their terminal block provided for this purpose. For example: air conditioner, heating manager…
    For the protection of the installation, it is recommended to use a circuit breaker or a gG fuse with a rated current suitable for the section of the cables.legrand 412173 DRIVIA Connected Dry-Contact Contactor -
Control Wiring examples (following)
    Control of single phase power contactor (example : swimming pool pump…)
    For the protection of the Dry-contact and the command circuit (terminal 1 and 2), it is mandatory to use a MCB or a gG fuse of rated current 2A.legrand
412173 DRIVIA Connected Dry-Contact Contactor - Control1 Control of charging station for electric vehicles
    For the protection of the installation, it is recommended to use a circuit breaker or a gG fuse with a rated current suitable for the section of the cables.legrand 412173 DRIVIA Connected Dry-Contact Contactor -
Control2

  2. Add the in a connected installation

|
---|---
Turn off the power at general circuit breaker| Turn on the power at the general circuit breaker*
once the installation completed and controlled**

  • In order to restart all connected products at the same time.
    **: After wiring the installation, refit the front plate so that no active live part is accessible.

    1. Finalize the installation Legrand Home+ Control smartphone app
      Download Home+ Control smartphone app and follow the instructions to add the connected product in your installation.
      You also have the possibility to remote-control your installation via a voice assistant and can customize your scenarios via the Home+Control app.

legrand 412173 DRIVIA Connected Dry-Contact Contactor -
icon9

Use by manual control and status LED

legrand 412173 DRIVIA Connected Dry-Contact Contactor -
control3

Reset a Connected Dry-Contact
to remove it from a connected installation
Press the configuration button of the Connected Dry-Contact (> 5 seconds) until the configuration indicator lights up in fixed red. It is no longer associated with the gateway present in the installation.

www.legrand.fr/reference/412173
LEGRAND – Pro and Consumer Service – BP 30076
87002 LIMOGES CEDEX FRANCE
 www.legrand.com
UE SIMPLIFIED DECLARATION OF CONFORMITY
The undersigned, Legrand
declares that the radio equipment listed on this instruction sheet
are compliant to the directive 2014/53/UE.
The full text of the UE declaration of conformity
is available at the following website: www.legrandoc.com