Connected Dry-Contact
4 121 73 – 1 991 23
Instructions
412173 DRIVIA Connected Dry-Contact Contactor
Requires the installation of a:
Composition
CE Directive , Compliant with the following European directive:
Low voltage directive (LVD) 2014/35/UE Electromagnetic compatibility (CEM) n°
2014/30/UE
| Supply N – L| Contact 1 – 2 Monostable| | | | Measure|
Shedding
---|---|---|---|---|---|---|---
| |
-5°C +45°C| 100-240V~ 50 / 60Hz| 30VDC Max 250VAC Max| 0,01A Min 2A Max| 2,4 to 2,4835Ghz
<100 mW| Silent < 10dB| Planning| 80A Max| Connected shedding
compatible
Imperative security precaution
The instructions for installation and use must be strictly observed in order to avoid the risk of electric shock or fire.
-
Preparation, connection Wiring examples
Control of any type of device from 12 to 30V DC via their terminal block provided for this purpose. For example: air conditioner, heating manager…
For the protection of the installation, it is recommended to use a circuit breaker or a gG fuse with a rated current suitable for the section of the cables. Wiring examples (following)
Control of single phase power contactor (example : swimming pool pump…)
For the protection of the Dry-contact and the command circuit (terminal 1 and 2), it is mandatory to use a MCB or a gG fuse of rated current 2A. Control of charging station for electric vehicles
For the protection of the installation, it is recommended to use a circuit breaker or a gG fuse with a rated current suitable for the section of the cables. -
Add the in a connected installation
|
---|---
Turn off the power at general circuit breaker| Turn on the power at the general
circuit breaker*
once the installation completed and controlled**
-
In order to restart all connected products at the same time.
**: After wiring the installation, refit the front plate so that no active live part is accessible.- Finalize the installation Legrand Home+ Control smartphone app
Download Home+ Control smartphone app and follow the instructions to add the connected product in your installation.
You also have the possibility to remote-control your installation via a voice assistant and can customize your scenarios via the Home+Control app.
- Finalize the installation Legrand Home+ Control smartphone app
Use by manual control and status LED
Reset a Connected Dry-Contact
to remove it from a connected installation
Press the configuration button of the Connected Dry-Contact (> 5 seconds) until
the configuration indicator lights up in fixed red. It is no longer associated
with the gateway present in the installation.
www.legrand.fr/reference/412173
LEGRAND – Pro and Consumer Service – BP 30076
87002 LIMOGES CEDEX FRANCE
www.legrand.com
UE SIMPLIFIED DECLARATION OF CONFORMITY
The undersigned, Legrand
declares that the radio equipment listed on this instruction sheet
are compliant to the directive 2014/53/UE.
The full text of the UE declaration of conformity
is available at the following website:
www.legrandoc.com
References
- 412173 Contact sec connecté Drivia with Netatmo avec contact maintenu NO livré avec un transformateur de courant fermé 80A maximum - professionnel | Legrand
- Legrand E-catalog International | Electrical Ranges of products & Connected Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>