Hunter 19432 3 Light Vanity Instruction Manual
- June 3, 2024
- Hunter
Table of Contents
Perch Point
For Models:
19432/ 19433
19432 3 Light Vanity
3 Light Vanity
Fixture weight ±2 lbs: 3.96 lbs (1.8 kg)
Here are the tools you’ll need to complete your installation:
| | | |
---|---|---|---|---
Ladder| Screwdriver| Pliers| Wire Strippers| Drill
INSTALLATION INSTRUCTIONS
WARNING
- To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
- The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
- All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.
READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. It is very important that
they are read carefully and completely before beginning the installation of
the lighting fixture.
PREPARING FOR INSTALLATION
Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the wall, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Put the drywall anchor (F) inside the hole in the wall. Remove cap nuts (I) from mounting screws (D). Place the mounting plate (A) over the junction box so that mounting screws (D) and nuts (C) extend out away from the wall. Pull the house wires through the center of the mounting plate (A). Secure mounting plate (A) to the junction box by tightening the screws (B) then insert the drywall screw (G) through the mounting plate (A) into the drywall anchor (F).
CONNECTING THE WIRES
Have a helper support the fixture’s weight while completing the wiring. Attach the fixture’s wires to the power supply wires from the junction box. Connect black to black (Live); white to white (grounded); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then, twist on a wire connector. Make sure all twists are in the same direction. Loop the fixture’s ground wire around the grounding screw (E) and tighten it. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.
FINISHING THE INSTALLATION
Place the fixture’s back plate (H) over the mounting screws (D) so the threads protrude through the holes on the front of the back plate. Tightly screw the cap nuts (I) onto the mounting screws (D) until the back plate (H) of the fixture is snugly against the wall. Install a light bulb (not included) in accordance with the fixture’s specifications. Do not exceed the recommended wattage. Turn on the power and test the fixture. Your installation is now complete.
CLEANING TIPS
Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray the cleaner directly onto the fixture.
NOTICE
Drill 9/64″ pilot holes in the support structure to aid in securing the light
fixture.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>