abode LU106BM-BB Ludlow Bridge Instruction Manual
- June 13, 2024
- abode
Table of Contents
abode LU106BM-BB Ludlow Bridge
5 Year Warranty Terms and Conditions
In the unlikely event that you should experience any defect in the materials or workmanship of your new Abode product within 5 years of purchase, the purchaser’s sole remedy shall be the replacement (at the manufacturer’s discretion) of all or any part of the product that is defective. All working parts and valves are guaranteed for a period of 5 years from purchase. Decorative surface finishes and O-rings are guaranteed for 1 year from the date of purchase provided that our advice concerning care has been observed and no scouring agents have been used. This is provided that the product has been used for normal domestic purposes only and that the care, installation and maintenance instructions have been observed. The warranty extends to the original purchaser only Marks, scuffs and scratches caused by improper installation or accidental damage are not covered by this guarantee. Neither are shade variations or any damage or defect caused by incorrect installation or abuse of the fitting.
As we are continuously improving and developing our range of products, finishes & colours, in the event of a valid claim, we may not be able to provide an identical replacement for the defective product throughout the guarantee period. Where an identical product is no longer available, we will supply the nearest equivalent from our then current product range. In assessing your claim, we must be given the opportunity to discuss your claim, review your proof of purchase and or inspect the product as installed prior to removal. Any agreed product return must be packaged as received and complete. No other warranties, express or implied, are made, including merchantability or fitness for a particular purpose. Under no circumstances shall the manufacturer be liable for any loss or damage arising from the purchase, use or inability to use this product, or for any special, indirect, incidental or consequential damages. No liability is accepted for consequential damage to other household fixtures, fittings or furnishings arising from this claim, even if attached to the product. No installer, dealer, agent or employee of Abode has the authority to modify the obligations or limitations of this warranty.
Important Care Instructions for your Product
To maintain the appearance of this product, ensure that it is regularly
cleaned only using a clean, soft damp cloth. A solution of warm water and a
mild liquid detergent may be used where necessary, and then the fitting rinsed
thoroughly and wiped dry. Any other cleaning action or use of common domestic
cleaning products will invalidate your warranty. If the product has a plastic
aerator insert at the end of the spout it should be unscrewed and the plastic
internal insert only removed and cleaned or descaled to maintain flow
performance. Do not use descaling solution on any decorative metal housing,
rinse the insert thoroughly before reattaching in the reverse order. Abrasive
cleaners, scouring cleaners and acidic cleaners must not be used on this
product under any circumstances. Avoid contact with all solvents (including
chlorinated solvents, ketones or acetones as these may result in surface
deterioration or etching). Also avoid contact with any harsh household
chemicals such as oven cleaners, drain cleaners, rust removers, paint
strippers and toilet bowl cleaners, bar keepers friend or Brasso.
Please leave these instructions for your customer.
Parts and Contents
Installation Instructions
Preparation
Before installing the new product it is essential that you thoroughly flush
through the supply pipes in order to remove any remaining solder, swarf or
impurities from your system. Failure to carry out this simple procedure could
cause problems or damage to the workings of the product or reduce performance
invalidating the warranty. We strongly recommend best practice of installing
particle filters and isolation valves to both the hot and cold feed pipes in
an accessible position. This will help to prevent premature failure of the
valves and ease any future maintenance. All parts should be removed from their
packaging and inspected for any transport damage prior to installation. Shut
off (isolate) your hot and cold water supply locally at the point of
installation before continuing with the installation. If the water cannot be
isolated locally the turn off the mains stopcock and power to any heating
system, now open the lowest tap or drain point in the system until both hot
and cold supplies are fully drained. This product requires a 35mmÆ tap hole,
if replacing an existing product, remove it and clean the end of the hot and
cold feed pipes using wire wool, the tap hole area should be free from dirt
and sealant. If the handles on the product operate backward and forwards,
allow for this when planning the sink or tap hole position. Loosely position
the product and fittings to check if any alteration to the existing pipework
is required, if needed, do this now.
Correct use of Flexible Hose Connectors
If this product is supplied with flexible hose connections for ease of
installation you must observe the conditions below, failure to observe these
standard installation guidelines will invalidate the warranty for your
product.
- Always screw the flexi hoses into the product only by hand, until feeling mechanical rest, a spanner must not be used on the product end of the connecting hose.
- Always use the pipes provided and not an alternative substitute
- Never twist or stretch the flexible hose during installation.
- Do not overtighten the hexagonal end of the hose connecting to the supply feeds when using a spanner causing the hose to twist.
- Before assembling the hose to the product ensure the hose ferrule has been crimped (as highlighted) on both ends of the hose after the braided hose sleeve.
- The braiding on the flexible hose must not be in contact with anything else, for example chemicals, internal or external room walls or dissimilar metals or materials or sharp objects.
- Hoses must not be double bent in multiple directions kinked or looped.
- Observe the minimum bend radius of 50mm.
- Both ends of the hose must have a minimum 50mm straight section before any bend.
Installation
- Screw the cold and hot water inlets (C) into the base of the mixertap (A), use rubber seals (B) to create a water tight seal between the parts. Note: the nuts on the base of the mixertap (A) should be tightened to the inlet legs when they are rotated to give the required center distance.
- Screw the base plinths (D) over the inlet legs (C) to the end of the threaded section before the bend.
- Push the seals (E & F) over the inlet legs flush to the underside of the base plinths (D).
- Place the mixertap (A) onto the sink or worktop and pass the inlet pipes (C) through the tapholes. With the tap in place check that the inlet pipes (C) meet the hot and cold water feeds. If further adjustment to the plumbing is required do this now. The hot water should be connected to the left hand side of the tap when viewed from the front.
- Fasten the fixing nuts (G) securely onto inlets (C) fixing the tap into its correct location.
- Connect the inlets (C) to the water supplies using ½” BSP compression fittings or similar.
After Installation:
Once you have visually checked the new fittings and connections, ensure that
all taps and drains are closed except the new product which should be left
open. Turn on (reconnect) the water supplies, check carefully for leaks around
the installation and product function. Once you are sure of no leaks, close
the new product and recheck for leaks, turn on the water heating power. Clean
and dry the product of any marks from installation then cover the product with
the bag provided to protect it until use.
Important Technical Data
- Maximum operating pressure: 500KPA (5bar)
- Recommended pressure: 300 KPA (3bar)
- Maximum hot water temperature: 70°C
- Recommended water temperature: From 5°C to 60°C
If these temperatures or pressures are exceeded, even for short periods, damage can result and will void your warranty In these instances, reduce the incoming water temperature and or install a pressure reducing valve. Ensure that your Abode product is fitted in accordance with Local Water Byelaws or regulations by a qualified installer. These installation guidelines have been prepared for your direction and you must exercise due care at all times. We do not accept responsibility for problems that may occur through improper installation. Whilst installing the product take care not to accidentally loosen any screwed assemblies.
Exclusively available from Turner Hastings Tel: 1300 00 2284 or www.turnerhastings.com.eu
- All errors and omissions excepted.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>