MASTER-BILT BHC-27 Series Ice Cream Hardening Holding Cabinet Instruction Manual
- June 16, 2024
- MASTER-BILT
Table of Contents
BHC Series
Installation & Operations Manual
Master-Bilt Products
908 Highway 15 North
New Albany, MS 38652
Phone: 800-684-8988
PN 295-90000
05-25-06
INTRODUCTION
Thank you for purchasing a Master-Bilt cabinet. This manual contains important instructions for installing, using, and servicing a Master-Bilt BHC case. A parts list is included with this manual. Read all these documents carefully before installing or servicing your equipment.
STORE CONDITIONS
The Master-Bilt BHC cases are designed to operate in the controlled
environment of an air-conditioned store. The store temperature should be at or
below 75°F and a relative humidity of 55% or less. At higher temperature or
humidity conditions, the performance of these cases may be affected and the
capacity diminished.
The Master-Bilt BHC should not be positioned where it is directly exposed to
rays of sun or near a direct source of radiant heat or airflow. This will
adversely affect the case and will result in poor performance.
If this case is to be located against a wall, there should be at least 4”
space between the wall and the back of the case.
This space will allow for the circulation of air behind the case, which will
prevent condensation on the exterior surfaces.
NOTICE
Read this manual before installing your cabinet. Keep the manual and refer to
it before doing any service on the equipment. Failure to do so could result in
personal injury or damage to the cabinet.
DANGER
Improper or faulty hook-up of electrical components on the refrigeration units
can result in severe injury or death.
All electrical wiring hook-ups must be done in accordance with all applicable
local, regional or national standards.
NOTICE
Installation and service of the refrigeration and electrical components of the
cabinet must be performed by a refrigeration mechanic and/or a licensed
electrician.
The portions of this manual covering refrigeration and electrical components
contain technical instructions intended only for persons qualified to perform
refrigeration and electrical work. This manual cannot cover every
installation, use or service situation. If you need additional information,
call or write us:
Customer Service Department
Master-Bilt Products
Highway 15 North
New Albany, MS 38652
Phone 800-684-8988
Fax 800-684-8988
WARNING LABELS AND SAFETY INSTRUCTIONS
This symbol is the safety-alert symbol. When you see this symbol on your
cabinet or in this manual, be alert to the potential for personal injury or
damage to your equipment.
Be sure you understand all safety messages and always follow recommended
precautions and safe operating practices.
NOTICE TO EMPLOYERS
You must make sure that everyone who installs, uses or services your cabinet
is thoroughly familiar with all safety information and procedures. Important
safety information is presented in this section and throughout the manual. The
following signal words are used in the warnings and safety messages: DANGER:
Severe injury or death will occur if you ignore the message.
WARNING: Severe injury or death can occur if you ignore the message.
CAUTION: Minor injury or damage to your cabinet can occur if you ignore
the message.
NOTICE: This is important installation, operation or service information.
If you ignore the message, you may damage your cabinet.
The warning and safety labels shown throughout this manual are placed on your
Master-Bilt Products cabinet at the factory. Follow all warning label
instructions. If any warning or safety labels become lost or damaged, call
your customer service department at
800-684-8988 for replacements.
This label is attached to the cabinet power cord label and on the wiring channel.
This label is located on top of the electrical control on models with a power cord.
PRE-INSTALLATION INSTRUCTIONS
INSPECTION FOR SHIPPING DAMAGE
You are responsible for filing all freight claims with the delivering truck
line. Inspect all cartons and crates for damage as soon as they arrive. If
damage is noted to shipping crates or cartons or if a shortage is found, note
this on the bill of lading (all copies) prior to signing. If damage is
discovered when the cabinet is uncrated, immediately call the delivering truck
line and follow up the call with a written report indicating concealed damage
to your shipment. Ask for an immediate inspection of your concealed damage
item. Crating material must be retained to show the inspector from the truck
line.
INSTALLATION INSTRUCTIONS
GENERAL INSTRUCTIONS
- Be sure the equipment is properly installed by competent service people.
- Keep the equipment clean and sanitary so it will meet your local sanitation codes. Clean the cabinet with a mild detergent and water, then rinse.
- Rotate your stock so that older stock does not accumulate. This is especially important for ice cream. A “First-In, First-Out” rotation practice will keep the products in good salable condition.
- Do not place product in the case when it is soft or partially thawed. Also, product should not be put in the case for at least 4 hours after it is started.
- Stock cases as quickly as possible, exposing only small quantities to store temperatures for short periods of time.
NOTICE TO STORE OWNERS / MANAGERS
Moisture or liquid around or under the cabinet is a potential slip/fall hazard
for persons walking by or working in the general area of the cabinet. Any
cabinet malfunction or housekeeping problem that creates a slip/fall hazard
around or under the cabinet should be corrected immediately.
If moisture or liquid is observed around or under a Master-Bilt cabinet, an
immediate investigation should be made by qualified personnel to determine the
source of the moisture or liquid. The investigation should determine if the
cabinet is malfunctioning or if there is a drainpipe leaking.
MECHANICAL
Remove front grille and check refrigeration lines to see that they are free
(not touching each other or compressor). Spin condenser fan blade to see that
it is free.
Check for electrical wires that may haved moved during shipping.
Remove cabinet from crate base and slide into location. Cabinet must be level
from side to side and front to back for correct draining of coil pan and for
self-closing doors to operate correctly. Allow minimum of 4″ between back of
cabinet and wall and between top of cabinet and ceiling for proper condensing
unit air circulation.
To comply with Sanitation requirements the cabinet must be mounted on legs (6″
high min.) or casters or the base must be sealed to the floor with an N.S.F.
listed silicone sealant.
To comply with UL requirements the cabinet must have a minimum clearance of 4″
at the top, 6″ at the rear and 0″ at each side.
ELECTRICAL
WARNING
Before servicing electrical components in the case or the doors or door frames
make sure all power to case is ff. Always use a qualified technician.
Check voltage and amps drawn on (Page 17) to determine proper line and fuse or
circuit breaker size. Check power supply for low voltage. If voltage reads
“230” with no load, and it drops below “207” when the compressor tries to
start, it is an indication of too small supply wiring or too long to run.
It is recommended that a separate circuit be run for each cabinet to prevent
another appliance blowing the fuse or breaker, causing loss of product. All
circuit breaker to be “HACR” type or fuses to be time delay type.
The cabinet should be grounded.
LOW TEMPERATURE FREEZERS “BHC” Models
The BHC has a power cord in the bottom of the cabinet at the right rear for
connection to power. On initial start-up the evaporator fan motors will not
start and you cannot initiate a defrost until the evaporator coil temperature
has lowered to 30°F. This is due to the thermostat. Also, the cabinet comes
with a non-adjustable “Front” control to keep the mullion heaters off until
the cabinet temperature has lowered to 10°F.
LEG AND CONDENSATE PAN INSTALLATION FOR TOP MOUNT CABINETS ONLY
- Screw legs or casters into existing crate mounting holes.
SERVICE INSTRUCTIONS
-
High head pressure and high back pressure:
A. Condenser coil clogged or restricted
B. Condenser fan motor defective.
C. Air discharge in rear of cabinet restricted. -
Low back pressure and low head pressure:
A. Restriction in system.
B. Refrigerant undercharged.
C. Leak in system -
Pressure normal cabinet warm:
A. Coil blocked with frost.
B. Refrigerant undercharged.
C. Control set too warm. -
Cabinet not cycling coil blocked with frost:
A. Defective temperature controller.
B. Refrigerant overcharged.
C. Location too hot.
D. Condenser clogged.
E. Condenser fan motor defective.
F. Defrost heater not operating. -
Compressor starts and runs but cycles on overload:
A. Low voltage B. Relay defective.
C. Overload defective.
D. High head pressure .
Temperature sensor, defrost heater and fan motor replacement
Before making any change, technician should:
- Disconnect power to the cabinet
- Remove screws from venturi and pull down
To change a temperature sensor (cabinet zone sensor or defrost termination
sensor), simply disconnect the sensor wires from the controller and replace
the new sensor in the original position. Use plastic tie to tighten the zone
sensor. Insert the sensor for defrost termination firmly into the evaporator
coil, in between the fins. Make sure the sensor wires do not touch or are not
close to any heater rods.
To change defrost heater remove screws from drain pan and pull down remove
screws from coil mounting straps spring straps open remove heater shield
pull heater out of slots in coil fins.
To change fan motor disconnect fan motor leads remove screws from fan
guards and motor mounts.
MASTER-BILT ELECTRONIC REFRIGERATION CONTROL
OPERATION
Compressor When power is first turned on to the control, the LED indicator
under COMP on the display starts blinking. After one-minute delay the
compressor comes on. The COMP LED indicator stays on while compressor relay is
energized. Display will show actual box temperature. Figure 4 is the display
layout. The compressor will be cycled off when the actual box temperature
reaches its set point. The COMP indicator will be off.
Fig. 4 Display Lay-out
Fan The fans will run constantly except when a defrost is initiated, the door’s are opened, or when the evaporator temp is above the 30oF. When in defrost mode the fan is off until the end of the defrost and the 2 minute drip time has passed. There is 4 minutes delay after a defrost before the fan comes on. The difference of the evaporator and room temperature of more than 9oF will override the fan delay. FAN LED indicator is on while FAN relay is energized.
Defrost The control uses timed defrosts with 3 defrosts per day. A programmed “HOT-KEY” has to be used to re-set the defrost scheme for special applications. During defrost the display will show dEF and the LED indicator under DEF in on.
MANUAL DEFROST
- Push this DEFROST key for more than 2 seconds and a manual defrost will start.
- While in defrost, Push and hold the DEFROST key for more than 5 seconds and the controller will end the defrost cycle. The controller will then enter drip mode for 2 minutes. The DEF led is flashing in drip mode.
HOW TO SEE THE SETPOINT (Box temperature cut-out)
- Push and immediately release the SET key: the display will show the Set point value;
- Push and immediately release the SET key or wait for 5 seconds to display the probe value (actual box temperature) again
HOW TO CHANGE THE SETPOINT
- Push the SET key for more than 2 seconds to change the Set point value;
- The value of the set point will be displayed and the LED under COMP starts blinking;
- To change the Set value push the UP ▲ or DOWN▼ arrows within 10s.
To memorize the new set point value push the SET key again or wait 10s.
HOW TO CHANGE a parameter value
- Enter the Programming mode by pressing the SET and DOWN ▼ keys for 3 seconds (LEDs under DEF and COMP start blinking).
- Select the required parameter by pushing the UP ▲ or DOWN▼ arrows
- Press the “SET” key to display its value (now only the COMP LED is blinking)
- Use “UP” or “DOWN” to change its value
- To exit: Press SET + UP ▲ or wait 15s without pressing a key.
NOTE 1: The set value is stored even when the procedure is exited by
waiting the time-out to expire.
NOTE 2: Master-Bilt’s SETPOINT for this cabninet is set at a recommended
–20°F at the factory for low temperature(LT).
NOTE 3: To scroll down the parameters without changing them, press the
DOWN button.
LIST OF PARAMETERS
Here is a list of the parameters the value of which can be changed in the
programming mode, as well as their ranges.
Parameter| Display Symbol| Description| Range|
Master-Bilt’s Setting
---|---|---|---|---
BHC-27 & 48
Temperature Set Point| Set| When this temperature is reached the compressor
LED will be off| -30 to 15°F| -20°F (-29°C)
Temperature Differential| Hy| Cut-out temperature is Set + Hy| 1 to 255°F|
10°F (6°C)
Maximum Temperature
Alarm| ALU| | 230°F| 30°F (-10°C)
Minimum Temperature
Alarm| ALL| | -58°F| -35°F (-37°C)
Temperature Alarm Delay| AId| | 0 to 255 min| 30min
Room Probe display| dP1| | |
Evaporator Probe Display| dP2| | |
ALARM SIGNALS
Message | Cause | Outputs |
---|---|---|
“P1” | Room probe failure | Compressor operated on time. 6min ON, 4 min OFF |
“P2” | Evaporator probe failure | Defrost end is timed |
“HA” | Maximum temperature alarm | Outputs unchanged. |
“LA” | Minimum temperature alarm | Outputs unchanged. |
NOTE:
Probe alarms “P1” and “P2” start some seconds after the fault in the related
probe; they automatically stop some seconds after the probe restarts normal
operation. Check connections before replacing the probe.
Temperature alarms “HA” and “LA” automatically stop as soon as the thermostat
temperature returns to normal values and when defrost starts.
FINAL CHECK LIST
A. Check operating pressures.
B. Check electrical requirements of unit to supply voltage.
C. Set temperature control for desired temperature range.
D. Check sight glass (if applicable) for proper refrigerant charge.
E. Check system for proper defrost settings and operation.
F. Check condensing unit for vibrating or rubbing tubing. Dampen and clamp as
required.
G. All valves should be completely opened counter-clockwise.
H. Check packing nuts on all service valves.
I. Replace all service valve caps and latch unit covers.
SENSOR PROBE
NOTICE: If the probe assembly is disconnected from the main board during
normal operation (unit running), the connectors must be installed in the same
position that they had before disconnection (P1 and P2), otherwise the control
will not function properly.
The Electronic Refrigeration Control sensors have NTC thermistors. The
reference resistance is 30,000 ohms at 77°F (25°C). It carries NTC thermistors
with a range of 40° to 199° F. In case there is a failure, these sensors
should be used in replacement of the sensors shipped with the control. In
order to diagnose faults in the probe, the control has LED functions as a
diagnostic tool. When power is supplied to the control, the LED will turn on
and will remain on as long as this condition is satisfied. When there is a
fault in the probe, the LED will blink intermittently. When this occurs, the
probe assembly needs to be replaced. If power is supplied to the control and
the LED remains off, there is a failure in the main relay control and it needs
to be replaced.
In case of a probe failure, the control will go into a safety mode of
operation. While in safety mode the control ignores probe inputs and cycles
the compressor on for 6 minutes and off for 4 minutes. The LED will be
blinking and signalling that there is something wrong with the probe. To
replace the sensor probes, disconnect power to the control, replace the probes
and restart the unit. Since the wire is fixed to the cabinet, a technician may
cut the sensor wire inside the cabinet and splice it with a new sensor.
SENSOR PROBE TEMPERATURE AND RESISTANCE
Temperature | Resistance |
---|---|
°F | °C |
-29.2 | -34 |
-20.2 | -29 |
-9.4 | -23 |
0.4 | -18 |
10.4 | -12 |
19.4 | -7 |
30.2 | -1 |
32.0 | 0 |
39.2 | 4 |
50.0 | 10 |
60.8 | 16 |
69.8 | 21 |
80.6 | 27 |
89.6 | 32 |
MASTER-BILT PART LIST
The table below gives Master-Bilt part numbers. Use this chart when ordering replacement parts for your IHC cabinets. Always Advise Cabinet Serial Number When Ordering Parts.
Description | BHC-27 | BHC-48 |
---|---|---|
115 Volt | 230 Volt | 230 Volt |
Cabinet Frame Heater | 17-09419 | 17-09150 |
Coil Defrost Heater | 1709407 | 17-09440 |
Compressor | 03-14902 | 03-14960 |
Condenser Coil | 07-13391 | 07-13391 |
Condenser Fan Blade | 15-13093 | 15-13093 |
Contactor | 19-13936 | 19-13934 |
Condenser Fan Motor | 13-00311 | 13-01283 |
Controller | 19-13918 | 19-13963 |
T-Sensor (2) | 19-13932 | 19-13932 |
Door Gasket | 37-01321 | 37-01321 |
Door Hinge-Outer Doors | 35-01450 | 35-01450 |
Door Trim | 29-01379 | 29-01379 |
Drain Line Heater | 17-00404 | 17-09063 |
Drain Fitting | 11-01410 | 11-01410 |
Drier | 09-09171 | 09-09171 |
Evaporator Coil | 07-13288 | 07-13288 |
Evaporator Fan Blade | 15-13106 | 15-13106 |
Evaporator Fan Guard | 25-01324 | 25-01324 |
Evaporator Fan Motor | 13-13181 | 13-13182 |
Expansion Valve | 09-09445 | 09-09445 |
Drain Line heater | 21-00577 | 21-00577 |
Front Control | 19-13897 | 19-13879 |
Heater Safety Control | 19-01164 | 19-01164 |
Leg Leveler | 27-00592 | 27-00592 |
Compressor Switch | 19-13118 | 19-13118 |
Shelves | 33-01763 | 33-01763 |
Air Valve | 11-01720 | 11-01720 |
Shelf Clip | 33-01011 | 33-01011 |
Switch Hinge | 35-01506 | 35-01506 |
Run Capacitor | 30MFD13700 | 30MFD13700 |
Start Capacitor | 233-28011650 | 188-10813300 |
Start Relay | 3ARR3-A3P6 | 3ARR3-A3A6 |
Accessories
Description | IHC-27 | IHC-48 |
---|---|---|
Casters (4) 5” diameter | A297-11140 | A297-11140 |
Voltage Boosting Transformer | 39-01080 (208-230V) | 39-01080 |
SALE AND DISPOSAL
OWNER RESPONSIBILITY
If you sell or give away your Master-Bilt cabinet you must make sure that all
safety labels and the Installation – Service Manual are included with it. If
you need replacement labels or manuals, Master-Bilt will provide them free.
Contact the customer service department at Master-Bilt at
800-684-8988.
The customer service department at Master-Bilt should be contacted at the time
of sale or disposal of your cabinet so records may be kept of its new
location.