Zip WATER BCS Celsius Plus All-In-One Zip HydroTap Instruction Manual

June 13, 2024
Zip WATER

Installation instructions
Zip Hydro Tap
Celsius Plus All-In-One
BC, BCS

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap

BCS Celsius Plus All-In-One Zip Hydro Tap

Visit our website to download the manuals

|
---|---

Using these instructions
Please refer to all safety and installation requirements detailed in the Quick start guide provided with the HydroTap Command Centre, and HydroTap Command Centre installation instructions found online, prior to installation of, or any change to, the complete system.

Before commencing the installation, download & read the Hydro Tap Command Centre installation instructions

Tools needed for installation (not supplied)
In addition to normal tools, the following (or equivalent equipment) will be required.

  • 50mm diameter sheet metal hole punch for sinks.
  • 50mm diameter hole saw for worktops.
  • Tube spanner for fixing the tap assembly.

Be aware of the risks of hazards which could cause harm when using tools. Assess the risks before starting the installation.

Water supply pressure requirements

| Min – Max pressure, kPA (bar)
---|---
| Australia| UK
HydroTap|  170 (1.7) – 700 (7.0)|  170 (1.7) – 500 (5.0)
Sparkling
HydroTap|  250 (2.5 ) – 700 (7.0)|  250 (2.5) – 500 (5.0)
Booster| 200 (2.0) – 700 (7.0)| 200 (2.0) – 500 (5.0)

Positioning

Position the tap such that it dispenses into the sink bowl with clearance for a cup or tea pot.

Ensure that taps are positioned to minimise the risks of scalding by dispensing boiling water while using the tap.

Position Command Centre and Tap as close together as possible.

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
1

Cut the hole

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
2

  • Cut a Ø50mm hole in the worktop / sink.
  • Make sure the tap location will allow the tap spout to drain into the sink.

Familiarise yourself with the mains connections

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
3

Familiarise yourself with the tap connections

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
4

Mount and secure the tap

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
5

Connect the water supply

All fittings are supplied apart from the isolation valve.
Valves and fittings must be sealed with PTFE tape.

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
6

Be careful with the sparkling pipework

  • Silicone tubes are soft and easily deformed. It is essential to avoid kinks, loops and sags.
  • Loosely cable-tie the rigid sparkling pipework to an adjacent braided hose to avoid kinks and squeezing.

Zip WATER BCS Celsius Plus All-In-One Zip HydroTap - Fig
7

Command Centre connections

Mains In Mains potable water supply.
USB Connected the Tap.
Boiling out Red silicone tube from tap. Cut to length.
Chilled out (BCS) Blue JG pipe from tap. Cut to length.

(BC) Blue silicone tube from tap. Cut to length.
Vent| Clear silicone tube from tap. Cut to length.
Sparkling out| White JG pipe from tap. Cut to length.

Cleaning and general maintenance

Wipe surfaces with a damp cloth and then wipe dry with a clean, dry cloth. Do not use disinfectant sprays without wiping dry afterwards.

Water Mark
WMK25927
AS/NZS 3718
Zip Water
67 – 77 Allingham Street, Condell Park, NSW 2200
Postal: Locked Bag 80, Bankstown 1885, Australia
(+612) 9796 3100 | Free Call (Aust): 1800 947 827
www.zipwater.com

Zip Water UK
Trafalgar House
Rash’s Green, Dereham,
Norfolk NR19 1JG
0345 6 005 005
specify.zipwater.co.uk

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals