Introduction
The evaluation kit allows an easy and fast evaluation of the AS5600 rotary
magnetic position sensor in the lab or together with an existing system. It
includes all required material to evaluate all product features.
This small adapter board is fully assembled with AS5600 position sensor and
its necessary external components. All relevant signals are available on a
dual-row 2.54mm 4-pin header footprint and can be easily wired to an existing
application.
The USB I&P Box is an easy-to use programming and demonstration tool. It can
be used to configure the device and to program a configuration.
A small magnet holder and a knob with a magnet attached on its shaft is
enclosed to show the functionality of the AS5600.
The AS5600 is a programmable Hall-based rotary magnetic position sensor with a
high-resolution 12-bit analog or PWM output for contactless potentiometers.
Based on planar Hall technology, this device measures the orthogonal component
of the flux density (Bz) from an external magnet while rejecting stray
magnetic fields.
The default range of the output is 0 to 360 degrees, but the full resolution
of the device can be applied to smaller range by programming a zero angle
(start position) and maximum angle (stop position).
The I²C interface is used for configuration and user programming of non-
volatile parameters in the AS5600. Additionally the device can be programmed
in 3-wire mode without any programmer.
1.1 Kit Content
This kit contains following material listed in Table 1. Additional material
can be found on our webpage.
Table 1: Kit Content
No. | Item | SAP | Info |
---|---|---|---|
1 | USB I&P Box | 990600795 | Programming and Interface Box |
2 | AS5600-SO_EK_AB | 990600786 | Adapter board including reference magnet |
3 | RMH05-DK-XX-1.0 | 990600534 | Rotary Magnet Holder with Knob |
For a detailed description of each item please refer to the specific manual. All manuals are available online on the amsAG website.
Getting Started
The AS5600 adapter board is ideal for rapid setup of a contactless
potentiometer because it includes all necessary tools to operate and configure
the AS5600.
This first steps describes how to connect and use the USB I&P Box together
with the AS560X Demo Software and the adapter board.
1st Install the AS5600 Demo Software
The Software is located on the USB drive that comes with the USB I&P Box or it
can be downloaded from our webpage. After Installation run the software.
2nd Assemble the Hardware Setup
Follow the Instructions shown below in Figure 1 to set-up the kit.
Figure 1: Setup Instructions
A. Short J1 on the adapter board to set-up the 3.3V mode
B. Connect the USB I&P Box with the AS5600-SO_EK_AB using the 10-way cable
C. Place the RMH05 over the adapter board
D. Connect the USB I&P Box using the USB cable to Computer.
The USB device is detected in Windows and by the AS560X Demo Software. The
setup is ready for demonstration.
Note: It might be necessary to perform a firmware update on the USB I&P Box if a wrong firmware was detected. In this case, the user will be prompted to allow an automatic firmware upgrade.
3rd Start using the software
Following steps are required to perform a configuration and to read-out the
AS5600. Refer to Figure
2 for reference. Read the software user manual for details.
A. Perform the desired configuration
B. Perform the required angle programming. Use the wizard function for
reference.
C. Verify the results
Figure 2: General Software Instructions
Ordering & Contact Information
Ordering Code | Description |
---|---|
AS5600-SO_EK_ST | AS5600 Eval Kit Standard Board |
Buy our products or get free samples online at:
www.ams.com/ICdirect
Technical Support is available at: www.ams.com/Technical-
Support
Provide feedback about this document at: www.ams.com/Document-
Feedback
For further information and requests, e-mail us at:
ams_sales@ams.com
For sales offices, distributors and representatives, please visit:
www.ams.com/contact
Headquarters
ams AG
Tobelbaderstrasse 30
8141 Unterpremstaetten
Austria, Europe
Tel: +43 (0) 3136 500 0
Website: www.ams.com
Copyrights & Disclaimer
Copyright ams AG, Tobel bader Strasse 30, 8141 Unterpremstaetten, Austria-
Europe. Trademarks Registered. All rights reserved. The material herein may
not be reproduced, adapted, merged, translated, stored, or used without the
prior written consent of the copyright owner.
Demo Kits, Evaluation Kits and Reference Designs are provided to recipient on
an “as is” basis for demonstration and evaluation purposes only and are not
considered to be finished end-products intended and fit for general consumer
use, commercial applications and applications with special requirements such
as but not limited to medical equipment or automotive applications. Demo Kits,
Evaluation Kits and Reference Designs have not been tested for compliance with
electromagnetic compatibility (EMC) standards and directives, unless otherwise
specified. Demo Kits, Evaluation Kits and Reference Designs shall be used by
qualified personnel only. ams AG reserves the right to change functionality
and price of Demo Kits, Evaluation Kits and Reference Designs at any time and
without notice.
Any express or implied warranties, including, but not limited to the implied
warranties of merchantability and fitness for a particular purpose are
disclaimed. Any claims and demands and any direct, indirect, incidental,
special, exemplary or consequential damages arising from the inadequacy of the
provided Demo Kits, Evaluation Kits and Reference Designs or incurred losses
of any kind (e.g. loss of use, data or profits or business interruption
however caused) as a consequence of their use are excluded.
ams AG shall not be liable to recipient or any third party for any damages,
including but not limited to personal injury, property damage, loss of
profits, loss of use, interruption of business or indirect, special,
incidental or consequential damages, of any kind, in connection with or
arising out of the furnishing, performance or use of the technical data
herein. No obligation or liability to recipient or any third party shall arise
or flow out of ams AG rendering of technical or other services.
Revision Information
Initial version 1-00
Changes from 0-00 (2014-Jul-2) to current revision 1-00 (2014-Jul-2)
Page
Initial version
Note: Page numbers for the previous version may differ from page numbers in the current revision.
ams Eval Kit Manual
[v1-00] 2014-Jul-02
Downloaded from Arrow.com.
Document Feedback
Documents / Resources
| ams
AS5600 Standard
Board
[pdf] User Manual
AS5600 Standard Board, AS5600, Standard Board, Board
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>