ams AS5600L Adapter Board Instruction Manual
- June 3, 2024
- ams
Table of Contents
AS5600L Adapter Board
Eval Kit Manual
AS5600L
Adapter Board
AS5600L-WL_EK_AB
AS5600L Adapter Board
Introduction
The AS5600L adapter board is a small PCB allowing simple and quick testing or
evaluation of the AS5600L magnetic position sensor without the need to build a
test fixture or design an own PCB.
1.1 Kit Content
Figure 1: Kit content
Pos. | Item | Comment |
---|---|---|
1 | AS5600L-WL_EK_AB | Adapter board |
2 | AS5000-MD6H-2 | Diametric Magnet, D6x2.5mm, NdFeB, Bomatec AG |
Board description
The PCB can either be connected to an external microcontroller or to the USB
I&P Box which is available on our webpage. (USB I&P Box)
P1 is populated with a 2×4 90-degree pin header and is required for power
supply as well as I2C (SCL, SDA) and PWM(OUT).
The connector J1 allows you to select between 5V or 3.3V operation
(Open=5V/Closed=3.3V) The optional resistor R1 (0R – 0603 package) allows you
to enable the 3 wire zero programming feature, where you can set the zero and
maximum position without using a µC. (for more details refer to the AS5600L
datasheet)
R2 and R3 are the optional pull-up resistors for SCL and SDA line.
C1 and C2 are decoupling capacitors.
R4 & R5 are used for the direction polarity. Populate R5 for increasing value
in a clockwise direction, R4 for counterclockwise.
Figure 2: AS5600L adapter board
2.1 Mounting the AS5600L adapter board
A 6×2.5mm diametric magnet has to be placed over or under the AS5600L sensor and should be centered on the middle of the sensors hall array (for hall array center please refer to AS5600L Datasheet). The airgap between the magnet surface and the package should be maintained in the range 0.5mm to 3mm. The magnet holder must not be ferromagnetic. Materials as brass, copper, aluminum, and stainless steel are the best choices to make this part.
AS5600L adapter board and pinout
Pin# Board | Pin# AS5600L | Symbol board | Type | Description |
---|---|---|---|---|
P1 – 1 | – | nc | – | Not connected |
P1 – 2 | C1 | SCL | Digital input | I²C Clock line |
P1 – 3 | – | nc | – | Not connected |
P1 – 4 | D1 | SDA | Digital input/output | I²C Data line |
P1 – 5 | – | nc | – | Not connected |
P1 – 6 | E3 | GND | Power supply | Ground |
P1 – 7 | D3 | OUT | Digital output | PWM output |
P1 – 8 | A3/C3 | VDD | Power supply | Positive voltage supply (5V / 3,3V mode) |
Operation case
4.1 I2C Mode
The AS5600L adapter board can be directly connected to an industry-standard
I2C port of a microcontroller. The minimum connection requirements for
bidirectional communication between the microcontroller and the AS5600L is
VDD, GND, SCL and SDA. The slave address is 0x40.
Figure 5: I2C Mode
AS5600L-WL_EK_AB Hardware
5.1 AS5600L-WL_EK_AB schematics
Figure 6: AS5600L-WL_EK_AB schematics
5.2
AS5600L-WL_EK_AB PCB layout
Figure 7: AS5600L-WL_EK_AB PCB layout
Ordering & Contact Information
Ordering Code | Description |
---|---|
AS5600L-WL_EK_AB | AS5600L Eval Kit Adapter Board |
Buy our products or get free samples online at: www.ams.com/ICdirect
Technical Support is available at: www.ams.com/Technical-Support
Provide feedback about this document at: www.ams.com/Document-Feedback
For further information and requests, e-mail us at: ams_sales@ams.com
For sales offices, distributors and representatives, please visit:
www.ams.com/contact
Copyrights & Disclaimer
Copyright ams AG, Tobelbader Strasse 30, 8141 Premstaetten, Austria-Europe.
Trademarks Registered. All rights reserved. The material herein may not be
reproduced, adapted, merged, translated, stored, or used without the prior
written consent of the copyright owner.
Demo Kits, Evaluation Kits, and Reference Designs are provided to the
recipient on an “as is” basis for demonstration and evaluation purposes only
and are not considered to be finished end-products intended and fit for
general consumer use, commercial applications and applications with special
requirements such as but not limited to medical equipment or automotive
applications. Demo Kits, Evaluation Kits and Reference Designs have not been
tested for compliance with electromagnetic compatibility (EMC) standards and
directives unless otherwise specified. Demo Kits, Evaluation Kits and
Reference Designs shall be used by qualified personnel only.
AMS AG reserves the right to change the functionality and price of Demo Kits,
Evaluation Kits, and Reference Designs at any time and without notice.
Any express or implied warranties, including, but not limited to the implied
warranties of merchantability and fitness for a particular purpose are
disclaimed. Any claims and demands and any direct, indirect, incidental,
special, exemplary or consequential damages arising from the inadequacy of the
provided Demo Kits, Evaluation Kits and Reference Designs or incurred losses
of any kind (e.g. loss of use, data or profits or business interruption
however caused) as a consequence of their use are excluded.
ams AG shall not be liable to the recipient or any third party for any
damages, including but not limited to personal injury, property damage, loss
of profits, loss of use, interruption of business or indirect, special,
incidental or consequential damages, of any kind, in connection with or
arising out of the furnishing, performance or use of the technical data
herein. No obligation or liability to the recipient or any third party shall
arise or flow out of ams AG rendering of technical or other services.
Revision Information
Changes from the previous version to current revision 1-00 (2017-Aug-11) | Page |
---|---|
Initial version 1-00 |
Note: Page numbers for the previous version may differ from page numbers
in the current revision.
Correction of typographical errors is not explicitly mentioned.
ams Eval Kit Manual
[v1-00] 2017-Aug-11
Document Feedback
Downloaded from Arrow.com.
Headquarters ams AG
Tobelbader Strasse 30
8141 Premstaetten Austria, Europe
Tel: +43 (0) 3136 500 0
Website: www.ams.com