ams AS5510 10-bit Linear Incremental Position Sensor User Manual
- June 12, 2024
- ams
Table of Contents
Product Document
AS5510 10-bit Linear Incremental
Position Sensor User Manual – AS5510 Demo Kit
AS5510
10-bit Linear Incremental Position
Sensor with Digital Angle output
General Description
The AS5510 is a linear Hall sensor with 10 bit resolution and I²C interface.
It can measure absolute position of lateral movement of a simple 2-pole
magnet.
Depending on the magnet size, a lateral stroke of 0.5~2mm can be measured with
air gaps around 1.0mm. To conserve power, the AS5510 may be switched to a
power down state when it is not used.
It is available in a WLCSP package and qualified for an ambient temperature
range from -30°C to +85°C.
Board Description
The AS5510 demo board is a complete linear encoder system with built-in
microcontroller, USB interface, graphical LCD display, incremental indicators,
incremental counter serial communication and PWM output LED.
The board is USB powered or externally supplied with a 9V battery for
standalone operation.
Figure 1:
AS5510-DK Demo Kit
Operating the Demo board
The AS5510 demo board can be powered in several ways:
-
Supplied by a 9V battery
Connect a 9V battery to the battery connector on the top right side of the board.
No other connection is required. -
Supplied by the USB port
Connect the demo board to a PC using a USB/USB cable (included in demo board shipment). The board is supplied by the 5V supply of the USB port. No other connection is required.
Turn the screw on the right side to move precisely the magnet left and right.
Hardware Indicators and Connectors
Display Description
The LCD display shows the realtime absolute magnetic field strength measured
by the AS5510:
Moving the slider from right to left will increase the absolute value until
4095 (19 99µm) with 0.488µm steps, then returns to zero.
Figure 2:
AS5510-DK Display in standalone mode
A) Filtering / Sampling mode
B) Magnetic Input Range
C) Magnetic Field in mT
D) Magnetic Field (0~1023)
E) Magnetic field barograph
Mode Switch S1
The Mode Switch S1 allows changing the parameters of the AS5510 and of the
demo board itself.
Depending on how long you keep S1 pressed, you will enter the Quick menu or
the Configuration menu.
Quick Menu
The Quick Menu changes the sensitivity setting of the AS5510.
Figure 3:
AS5510-DK Display Quick Menu
From the main screen, press S1 shortly (<1s).
The current Range and sensitivity setting will appear. At that moment, press
S1 shortly again to toggle the 4 sensitivity settings of the AS5510.
When the desired sensitivity is chosen, wait 2 seconds, and the demo board
will display the main screen back with the new sensitivity setting.
Adjust the sensitivity depending on the peak of the magnetic field present on
the AS5510.
The optimum sensitivity using the 4x2x1 magnet on this demo board is +/25mT.
Figure 4:
AS5510-DK Configuration menu
From the main screen, press and hold S1 during 2 seconds.
The configuration menu will appear.
By pressing S1 shortly, the next item is chosen.
To validate the pointed item, press and hold S1 during 2 seconds.
-
AVG 16X
Does an average of 16 consecutive values of the 10-bit output. This is used to reduce the jitter of the magnetic field value. The AS5510 is configured in Slow Mode (12.5kHz ADC sampling frequency). -
AVG 4X
Does an average of 4 consecutive values of the 10-bit output. This is used to reduce the jitter of the magnetic field value. The AS5510 is configured in Slow Mode (12.5kHz ADC sampling frequency). -
No AVG
Direct read of the 10-bit output. The AS5510 is configured in Slow Mode (12.5kHz ADC sampling frequency). -
FAST
Direct read of the 10-bit output. The AS5510 is configured in Fast Mode (50kHz ADC sampling frequency). -
I2C 56H
The demo board communicates with the I²C address 56h. This is the default address.
The on-board AS5510 must be used with this address only. -
I2C 57H
The demo board communicates with the I²C address 57h. This address can be used for an external AS5510 connected on J4, and S1 configured on EXT. This address -
POL = 0
Selects the default magnet polarity -
POL = 1
Selects the inverted magnet polarity
Encoder Selection Switch
The switch SW1 selects the encoder which communicates with the microcontroller
through the I²C bus.
- INT (Bottom position, default): Onboard AS5510
- EXT (Top Position): External AS5510 connected on J4.
The signals of the I²C interface (SCL, SDA) and the power supply (3.3V, GND) of an external AS5510 can be connected directly to J4. In this configuration, all the data from the external AS5510 are displayed on the LCD display.
Demo board block diagram, schematics and layout
Figure 5:
AS5510-DK Demo board block diagram
Figure 6:
AS5510-DK Demo board schematic
Figure 7:
AS5510-DK Demo board PCB layout
Ordering Information
Table 1:
Ordering Information
Ordering Code | Description | comments |
---|---|---|
AS5510-DB | DemoKit for AS5510 Linear Position Sensor |
Copyright
Copyright © 1997-2013, ams AG, Tobelbader Strasse 30, 8141 Unterpremstätten,
Austria-Europe.
Trademarks Registered ®. All rights reserved. The material herein may not be
reproduced, adapted, merged, translated, stored, or used without the prior
written consent of the copyright owner.
All products and companies mentioned are trademarks or registered trademarks
of their respective companies.
Disclaimer
Devices sold by ams AG are covered by the warranty and patent indemnification
provisions appearing in its Term of Sale. ams AG makes no warranty, express,
statutory, implied, or by description regarding the information set forth
herein or regarding the freedom of the described devices from patent
infringement. ams AG reserves the right to change specifications and prices at
any time and without notice. Therefore, prior to designing this product into a
system, it is necessary to check with ams AG for current information.
This product is intended for use in normal commercial applications.
Applications requiring extended temperature range, unusual environmental
requirements, or high reliability applications, such as military, medical
life-support or life sustaining equipment are specifically not recommended
without additional processing by ams AG for each application. For shipments of
less than 100 parts the manufacturing flow might show deviations from the
standard production flow, such as test flow or test location.
The information furnished here by ams AG is believed to be correct and
accurate. However, ams AG shall not be liable to recipient or any third party
for any damages, including but not limited to personal injury, property
damage, loss of profits, loss of use, interruption of business or indirect,
special, incidental or consequential damages, of any kind, in connection with
or arising out of the furnishing, performance or use of the technical data
herein. No obligation or liability to recipient or any third party shall
arise or flow out of ams AG rendering of technical or other services.
Contact Information
Headquarters ams AG
Tobelbader Strasse 30
8141 Unterpremstätten
Austria T. +43 (0) 3136 500 0
For Sales Offices, Distributors and Representatives, please visit:
http://www.ams.com/contact
www.ams.com
Revision 1.1 / 02/04/13
Downloaded from Arrow.com.