ARROW CDC-12123-XPN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization for High Volume Infusions Instructions
- June 12, 2024
- Arrow
Table of Contents
CDC-12123-XPN1A Pressure Injectable Three-Lumen
Hemodialysis Catheterization for High Volume
Infusions Instructions
CDC-12123-XPN1A
Pressure Injectable Three-Lumen Hemodialysis Catheterization for High
Volume Infusions
1: Three-Lumen Catheter: 12 Fr. (4.06 mm OD) x 16 cm Pressure Injectable
Radiopaque Polyurethane with Blue FlexTip®, Extension Line Clamps
1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. x 23-5/8″ (60 cm) (Straight
Soft Tip on One End – “J” Tip on Other) with Arrow® GIideWheelTM Wire Advancer
1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer
Needle
1: Injection Needle: SafetyGlide mil 25 Ga. x 1″ (2.54 cm)
1: Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm)
1: Pressure Transduction Probe
1: Introducer Needle: Echogenic 18 Ga. x 2-1/2″ (6.35 cm) XTW and 5 mL Arrow®
Raulerson Spring-Wire Introduction Syringe
1: Injection Needle: SafetyGlide Tml 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-
Slip Syringe
1: Syringe: 3 mL Luer-Lock 1: Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm
1: Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm
3: 10 mL Luer-Lock Pre-Filled Saline Syringe
1: 5 mL 1% Lidocaine HCI Solution and Alcohol Prep
2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrepo2 One-Step Solution with Hi-
Lite Orange™Tint
1: Sharps Away® II Locking Disposal Cup
1: Sharps Away® Disposal Cup
1: Maximal Barrier Drape”‘ with 4″ fenestration
1: Towel 1: Needle Holder
1: Safety Scalpel: #11
1: Checklist/CLIP Sheet
1: Sterile Procedure Sign
1: Medication Label: 1% Lidocaine
2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
1: Surgical Apparel: Impervious Gown
1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm
1: Dressing: BIOPATCHe3
1: Transducer Cover: 14 cm x 147 cm
1: Surgical Apparel: Mask with Eye Shield
1: Surgical Apparel: Bouffant Cap
1: Suture: 3-0 Silk with Curved Needle
1: Tubing±: 20″ (50 cm) Extension
1: HemoHopperc) Fluid Receptacle
IA trademark of Becton, Dickinson and Company.
2A registered trademark of CareFusion or one of its subsidiaries.
3 A registered trademark of Johnson & Johnson Corporation.
±Precaution:Contains Phthalate:DEHP.
Warning:Theresultsofcertainanimalexperimentshaveshownphthalatestobepotentiallytoxictoreproduction.Proceedingfromthepresentstateofscientificknowledge
,risksformaleprematureinfantscannotbeexcludedinthecaseoflong-
termexposureorapplication.Medicalproductscontainingphthalatesshouldbeusedonlytemporarilywithpregnantwomen,nursingmothers,babiesandinfants.Notmadewithnaturalrubberlatex.Storebetween20–25°C(68–77°F).
ArrowInternationalprovidestheenclosedmedicationlabel(s)foryourconvenience.Pleaseensurethattheselabelsareappliedtothecorrectsyringeandcorrespondingmedication.
Contraindications:The Multi-Lumen Acute Hemodialysis Catheter(AHDC)isn’t
designed for long-term(≥30days)hemodialysis or for insertion into thrombosed
vessels.
LBL068956 R 00 (2023-04)
Documents / Resources
|
ARROW CDC-12123-XPN1A Pressure Injectable Three-Lumen Hemodialysis
Catheterization for High Volume
Infusions
[pdf] Instructions
CDC-12123-XPN1A Pressure Injectable Three-Lumen Hemodialysis Catheterization
for High Volume Infusions, CDC-12123-XPN1A, Pressure Injectable Three-Lumen
Hemodialysis Catheterization for High Volume Infusions, Injectable Three-Lumen
Hemodialysis Catheterization, Three-Lumen Hemodialysis Catheterization,
Hemodialysis Catheterization, Catheterization
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>