- Product Name: CDC-26122-XN1A
- Catheter Type: Two-lumen catheter
- Catheter Size: 12 2 Fr.
- Catheter Length: 25 cm
- Guide Wire Diameter: 0.035 inch
- Contents:
- Catheter: 18 Ga. x 2-1/2 (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- Raulerson Spring-Wire Introduction Syringe
- Injection Needle: SafetyGlideTM1 22 Ga. x 1-1/2 (3.81 cm) and 5 mL Luer-Slip
- Contraindications:
- Not suitable for long-term (30 days) hemodialysis
- Not suitable for use in patients with thrombosed vessels
- Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/or sulfa drugs
Product Usage Instructions
- Prepare the patient and the necessary equipment for catheter insertion
- Ensure that the catheter is properly sterilized before use.
- Select an appropriate insertion site and clean the area with an antiseptic solution.
- Using the provided introducer needle, perform the initial puncture at the selected site.
- Advance the catheter into the vessel while removing the introducer needle.
- Secure the catheter in place using the appropriate fixation method.
- Connect the Raulerson Spring-Wire Introduction Syringe to the catheter for priming.
- Prime the catheter by injecting 1.40 mL of fluid into the distal lumen and 1.60 mL into the proximal lumen.
- Ensure that the priming volumes are approximate and are done without accessories.
- Monitor the pressure and flow rate during dialysis using the provided dialysis flow rate chart.
- Follow the recommended flow rate for venous and arterial lines according to the chart.
Note: It is important to read and understand the complete user manual before using the product. Consult a healthcare professional for any specific usage guidelines or concerns.
INSTRUCTION
- 1: Two-Lumen Catheter: 12 Fr. (4.06 mm OD) x 25 cm Radiopaque Polyurethane with Blue FlexTip®, Arrowg+ard® Antimicrobial Surface Treatment, Extension Line Clamps
- 1: Spring-Wire Guide, Marked: .035″ (0.89 mm) dia. × 23-5/8″ (60 cm) (Straight Soft Tip on One End – “J” Tip on Other) with Arrow® GlideWheel™M Wire Advancer
- 1: Catheter: 18 Ga. x 2-1/2″ (6.35 cm) Radiopaque over 20 Ga. RW Introducer Needle
- 1: Injection Needle: SafetyGlide ™M 1 25 Ga. × 1″ (2.54 cm)
- Blunt Fill Needle: 18 Ga. x 1-1/2″ (3.81 cm) Pressure Transduction Probe
- Introducer Needle: Echogenic 18 Ga. × 2-1/2″ (6.35 cm) XTW and 5 mL Arrow® Raulerson Spring-Wire Introduction Syringe
- 1: Injection Needle: SafetyGlide ™M 1 22 Ga. x 1-1/2″ (3.81 cm) and 5 mL Luer-Slip Syringe
- Syringe: 3 mL Luer-Lock
- Tissue Dilator: 10 Fr. (3.5 mm) x 10.2 cm
- Tissue Dilator: 12 Fr. (4.0 mm) x 14 cm 10 mL Luer-Lock Pre-Filled Saline Syringe 5 mL 1% Lidocaine HCI Solution and Alcohol Prep
- 2: 3 mL Applicator 2% CHG and 70% IPA ChloraPrep®2 One-Step Solution with
Precaution: Contains
Phthalate: DEHP.
Warning: The results of certain animal experiments have shown phthalates to be potentially toxic to reproduction. Proceeding from the present state of scientific knowledge, risks for male premature infants cannot be excluded in the case of long-term exposure or application. Medical products containing phthalates should be used only temporarily with pregnant women, nursing mothers, babies and infants. Not made with natural rubber latex. Store between 20 – 25°C (68 – 77°F). Arrow International provides the enclosed medication label(s) for your convenience. Please ensure that these labels are applied to the correct syringe and corresponding medication. Contraindications: The Arrow large-bore two-lumen catheter is not designed for long-term (≥ 30 days) hemodialysis or for use in patients with thrombosed vessels. The Arrowg+ard Blue antimicrobial catheter is contraindicated for patients with known hypersensitivity to chlorhexidine, silver sulfadiazine, and/ or sulfa drugs.
- Hi-Lite Orange ™ Tint
- 1: SharpsAway® I| Locking Disposal Cup
- 1: SharpsAway® Disposal Cup
- 1: Maximal Barrier Drape ™ with 4″ fenestration
- 1: Towel
- 1: Needle Holder
- 1: Safety Scalpel: #11
- 1: Checklist/CLIP Sheet
- 1: Sterile Procedure Sign
- 1: Medication Label: 1% Lidocaine
- 2: Gauze Pad: 2″ x 2″ (5 cm x 5 cm)
- 5: Gauze Pad: 4″ x 4″ (10 cm x 10 cm)
- 1: Surgical Apparel: Impervious Gown
- 1: Dressing: I.V. Advanced 8.5 cm x 11.5 cm
- 1: Dressing: BIOPATCH®3
- 1: Transducer Cover: 14 cm x 147 cm
- 1: Surgical Apparel: Mask with Eye Shield
- 1: Surgical Apparel: Bouffant Cap
- 1: Suture: 3-0 Silk with Curved Needle
- 1: Tubing: 20″ (50 cm) Extension
- 1: HemoHopper® Fluid Receptacle
- 1A trademark of Becton, Dickinson and Company.
- 2A registered trademark of CareFusion or one of its subsidiaries.
- 3A registered trademark of Johnson & Johnson Corporation.