USER MANUAL
uFlamer
V2.2
2022/11
Showven Technologies Co., Ltd.
Foreword
Thanks for choosing SHOWVEN uFlamer, we wish it will bring you lots of
exciting moments. Please read the following manual carefully before operating
this product. Operate according to instructions is very important for safety,
and can elongate the service life of the machine Strictly follow the
instruction in the manual when operate uFlamer. If you have any doubts, please
contact SHOWVEN technologies Co., Ltd by
info@showven.cn
We assume the person who use or come in contact with the device are familiar
with how the device should be handled. This includes proper use, maintenance
and repair of the machine as defined in this user manual.
Warning
-
This product is only suitable for qualified or skilled operators who has experience with the technology of the device and is particularly informed about the types of fuel used by the device.
-
Unauthorized repair are prohibited, it may cause serious incident
-
Make sure power supply in consistent with the rated voltage of the equipment, and the socket must well grounded. Unplug and turn off the machine when not use
-
Before connect the power cable, communication DMX cable should well connected and ensure the command keep at firing OFF status. And safety lock of uFlamer stay at TEST MODE.
-
Before power on the machine, please check carefully the safety distance and make sure it meets the requirements in this manual.
-
The device can only be placed horizontally.
-
After turning on the device, no person allows to stay in the danger area. Ensure all persons that are part of the show be informed about the safety distance, risks and functions of the device
-
Always have a CO2 fire extinguisher and an extinguishing blanket in case of needed
-
If there be any doubt as to the safety operation of the device in any circumstances, the device should be taken out of service immediately. Be sure the device is in good operating condition before use. If fail to fire correctly, immediately shut down and check it accordingly
-
Be sure to use high quality flame fluid, otherwise, it is easily leads to failure or danger. Be careful when refill the flame fluid tank. Please keep flame fluid away from heat source, sparks, fire or other possibility of ignition. Do not smoke!
-
The operator responsible for the control of uFlamer must always have a clear view of the device, so that he/she can stop the show immediately when there is danger. The main AC power switch should near
operator. So that operator can turn off the power of all devices in case of abnormal -
The device shall not be altered and applied to other use purpose
Disclaimers
SHOWVEN technologies Co., Ltd. excludes liability for unsafe situations, accidents and damages resulting from:
- Ignoring warnings or regulations as shown on flamer or this manual.
- Use for other applications or circumstances other than those indicated herein.
- Changes to the flamer, including use of non-original spare parts.
- Removed safety cover without authorization from SHOWVEN.
- Use this machine by unqualified or untrained personnel. 6. Improper use of machine.
Functional Characteristics
- Fluid driven vertical flamer original designed by SHOWVEN
- Flame up to 8-10m, indoor nozzle optional
- Dual igniter, built-in pump, plug and play system
- Super compact pumping system design, easy carrying
- Stainless steel housing, can be used in rainy weather, reliable and durable
- Built-in 5L fuel tank, no external hose connection needed
- Safety lock with switchable test mode, safer for service
- Tilt protection, the tilt sensor will be activated when machine slant Over 45°
- Intelligent control system, safer for use
- Standard DMX control, compatible with all DMX console
- Neutrik® powerCON TRUE1 connectors
- Built-in battery optional
Technical Specifications
- Model: uFlamer
- DIMENSION: 330×260×320mm
- WEIGHT: 14kg
- VOLTAGE: 100-240V, 50/60Hz
- POWER: 300W
- CONTROL: DMX
- INTERFACE: 3-pin&5-pin DMX IN/OUT
- FLAME HEIGHT: 8-10m (no wind)
- FUEL: ISOPROPANEL, ISOPAR-G,H,L,M
- FUEL TANK CAPACITY: 5L
- FUEL CONSUMPTION RATE: 60ml/s
- FUEL LEVEL SENSOR: YES
- EFFECT DIRECTION: Vertical
- IGNITION: High voltage electron ignition
- IGNITOR: Dual
- BUILT-IN BATTERY: OPTIONAL
- USAGE IN RAIN: YES
Structure of uFlamer
- Firing Box
- Top Panel
- Fuel Bottle Area
- Control Panel
- Safety Loop
- Igniter (dual)
Overview of Bottom Panel
Overview of Control Panel
- LCD screen operate panel
- ON/OFF switch (pressurized indicator light, blue LED)
- Safety Lock (safety indicator light, red LED)
- 5-pin DMX socket (Wireless DMX512 power DC5V between 1 and 4 pin)
- 3-pin DMX socket
- Power socket
- Charging Input
Operation Panel
-
LED Display Area:
RX: Radio receiving (reserved)
DMX: DMX signal. Flash means DMX signal available, otherwise no DMX signal
ERR: Light on when there is an error
PUMP: Light on when pump is running -
Button Functions:
MENU: Switch interface to setup parameter;
+: Parameter Up
-: Parameter Down
ENTER: Confirm and save parameters (screen will flash when parameters saved)
Note: screen display will switch to main interface if there is no operation in 15s. -
Welcome Interface:
First Line: Product model and software version Second Line: Equipment series number -
Main Interface:
First Line:
Operational DMX address (FIRE) and Safety DMX address (safe) under DMX Channel Mode 2CH-P;
DMX address under DMX Channel Mode 6CH and 2CH-N;
Second Line: Pressure 75 (e.g. 100=10bar); V: 13.6 means internal voltage is 13.6V. -
Alert Message:
Alert Message| Why it appears| How to remove
---|---|---
E0 Test Mode| Safety Switch at TEST MODE| Switch to USER MODE
E0 Factory Mode| Factory mode| Switch to Normal mode -
Error Message:
Error Message| Why it appears| Reason / How to remove
---|---|---
E1 Pressure
Err
| Pressurize for 8s, pressure value
failed to reach target value
| No fuel, pump failure, pipeline leakage etc reason,
please check accordingly
E2 P Relief Err| Depressurize for 3s, pressure value ≥
50% of target value
| pressure relief valve failure
E5 Voltage Err| DC input < 11V or > 18V| Make sure DC input between
11-18V
E6 Tip Err| Machine slant over 45°| Tip setting set to OFF, or
horizontal install machine.
E7 Low Fuel| Fuel level low| Fill the tank or Switch OFF the liquid
level sensor
7. Interface setup:
Press “MENU” to switch through setup menu, press and hold “MENU” 3s back to
main interface. DMX Channel Mode| Menu| Range| Explanation
---|---|---|---
6CH / 2CH-N| Set DMX Address| 1~511| DMX address setup
2CH-P
| Fire Address| 1~511| Fire address setup
Safety Address| 1~512| Safety address setup
8. Advanced Interface:
Press “MENU” 3s enter advanced interface, press “MENU” to switch interface,
press “MENU” 3s can back to main interface. The value in bold character is
default value. Items| Contents| Description
---|---|---
Drive Test
| OFF / Pump / Igniter / Relief Valve / Jet Valve
1. Pump| Pump running, if pressure reached the target
value, the pump will not running.
2. Igniter| Ignite 1s
3. Relief Valve| Relief valve will be on and off for 3 times
4. Jet Valve 1| Safety lock located at user mode, release pressure
for a period of time, jet valve will be on and off for 3 times
5. Jet Valve 2(none)
Language| English / Chinese| Language switch
Mode Select| Normal Mode / Factory Mode| Factory mode is for test in
factory only
Tip setting| ON / OFF| Turn ON/OFF tip over function
DMX Channel Mode| 2CH-P / 6CH / 2CH-N| Change the DMX Channel Mode.
Low Fuel Switch| ON / OFF| Turn ON/OFF the fuel level sensor
Default Parameter| OFF / ON| Reset default parameter settings
DMX CONTROL
uFlamer with 3 different channel mode: 2CH-P, 2CH-N and 6CH.
2CH-P:
In this channel mode uFlamer occupies 1 functional channel and 1 separate
safety channel (this channel is independent from operational channel, can be
shared with other machine).
Channel | Function | Value |
---|---|---|
Functional Channel | Firing | 0~110: Firing OFF |
111~255: Firing ON
Safety Channel
| Device enable / disable| 0~49: Depressurize mode, disable device (Emergency STOP)
50~200: Pressurize mode, enable device
201~255: Depressurize mode, disable device (Emergency STOP)
2CH-N:
In this channel mode uFlamer occupies 2 functional channel.
Channel | Function | Value |
---|---|---|
CH-1 | Firing | 0~110: Firing OFF |
111~255: Firing ON
CH-2| Pressurize / Depressurize| 0~239: Depressurize mode (Emergency STOP)
240~255: Pressurize mode, enable device
6CH:
In this channel mode uFlamer occupies 6 functional channel. This channel mode
is designed to control the uFlamer together with CIRCLE FLAMER on our Host
Controller.
Channel | Function | Value |
---|---|---|
CH1 | – | – |
CH2 | – | – |
CH3 | Firing ON/OFF | 0~253: Firing OFF |
254~255: Firingn ON
CH4
|
Firing Duration setup
| 0 and 255: permanent fire (8s is limit duration time)
1~254: 10~2540ms duration time
(Manual firing duration = DMX Value * 10ms)
CH5| –| –
CH6
|
Pressurize / Depressurize
| 0~49: Depressurize (Emergency Stop)
50~200: Pressurize
201~255: Depressurize (Emergency Stop)
Control with SHOWVEN Host Controller ZK6200/ZK6300
If use SHOWVEN Host Controller ZK6200 or ZK6300 to program the uFlamer, after set DMX channel mode on uFlamer please also set on Host Controller. The setting step is: Press “F3” on Host Controller – find “Device” – choose the right device “CIRCLE FLAMER” (6CH mode). Host Controller with bi-directional communication with device, please allocate a unique DMX address for each unit of uFlamer. FIRING HEIGHT is meaningless, just need to set the FIRING DURATION.
Operation
- Safety Distance
Definition and Instructions
Safety distance for uFlamer divided into two parts safety radius around machine (a) and safety distance at firing direction (b). No person and flammable materials are allowed to stay inside the safety isolation zone when flamer was armed.
The safety radius around machine depends on the firing height (nozzle size), with a radius from 2.5m to 3m.
For safety distance at firing direction equals to maximum firing height * 1.5.
Nozzle Type| Max. Flame Height| Safety Radius around
uFlamer (a)
| Safety Distance at Firing
Direction (b)
---|---|---|---
SFSMA002 Nozzle M| 10m| 3m| 15m
SFSMA003 Nozzle L| 8m| 2.5m| 12m
The uFlamer safety isolation zone (show as below) is a cylindrical three-
dimensional space with Safety radius around machine (a) and Height of b.
Unauthorized persons and objects are strictly prohibited from entering.
For angled installation, the safety distance both around machine and firing
direction should shift accordingly.
Safety distance in windy environment
The safety isolation zone radius (a) and safety distance of firing direction
(b) increase with wind direction and
wind speed (v, m/s). The safety distance in windy conditions can be calculated
as below:
For Nozzle M: a = 3 + v; b = 15 + v
For Nozzle L: a = 2.5 + v; b = 12 + v
For example when the wind speed is 3m/s, we use the Nozzle M on uFlamer, then
the safety isolation zone radius should be 6m, safety distance of firing
direction is 18m.
When the wind speed ≥ 8m/s (wind force ≥ 5), please use it with caution. When
wind speed ≥ 17m/s wind force ≥ 8 , please stop use uFlamer.
Safety mark
Label of uFlamer
Fuels for uFlamer
- Water content in fuel should less than 0.5%
- For maximum safety, please use fuel with flash point between 60-80℃, ISOPAR L is highly recommended.
- Ethanol is not suggested due to three reasons, first ethanol is highly flammable makes it not as safe as ISOPAR; secondly the color of flame is very weak; thirdly there are always high water content (> 0.5%) in ethanol.
- Colored fuels are forbidden to use on uFlamer it may damage the machine.
SHOWVEN excludes liability for the losses, damages and accidents caused by not using qualified fuels in accordance with this requirement.
Always have a dry powder fire extinguisher, a CO2 fire extinguisher and an extinguishing blanket next to the equipment in case of needed. And someone must be on duty during operation. In case accident occurs, a dry powder fire extinguisher can be used when the fire is large, and a carbon dioxide fire extinguisher can be used when the fire is small.
2. Install uFlamer
a) Choose the correct nozzle, ensure the installation position of uFlamer meet
above safe distance requirements. New uFlamer supplied with a nozzle M which
generate up to 10m flame.
b) Horizontal installation is preferred for uFlamer. If need to install
uFlamer in angles, to avoid fake error message please turn the TIP Setting and
Low fuel switch to OFF status first. uFlamer with maximum tilt angle of 45° or
-45°, and it can be angled to two directions as show in below picture. Besides
please be aware the fuel level in fuel tank to avoid fuel leakage when tilt
installation.
c) For truss installations always connect with safety rope to ensure extra
safety. If there is any other national or regional guidelines please follow it
accordingly.
d) Double confirm the machine was firmly installed.
3. Connect Power and DMX cable to uFlamer
Before power and/or DMX cable connection, make sure safety button of uFlamer
stay at TEST MODE. When safety button is pressed down, it is USER MODE; when
it pops up, it is TEST MODE. So before connect power and DMX cable make sure
the safety button of uFlamer pops up.
a) Connect a power cable to the POWER IN socket of uFlamer. Connect the other
end of power cable to the power source. Make sure power supply in consistent
with the rated voltage of the equipment, and the socket must well grounded.
b) Each unit of uFlamer can be connected to power supply directly. If connect
machine in sequence, please connect a power link cable to the POWER OUT of
previous machine, connect the other end of the power link cable to POWER IN of
the next machine. Do not connect exceed units to a single electrical circuit.
c) Power on all uFlamer. Check the safety button, double confirm it stays at
“TEST MODE”.
d) Assign DMX address for each unit of uFlamer. If use SHOWVEN host controller
or FXcommander to control the machine please allocate a unique DMX address for
each unit of machine.
e) Connect a DMX cable to the DMX IN socket of first unit of uFlamer, another
head of this DMX cable connect to DMX console (such as FXcommander). Make sure
the DMX console is powered off.
f) Connect a DMX cable to the DMX OUT socket of previous uFlamer, and the
other end to the DMX IN of next machine. Connect all devices in series in this
way.
g) Suggest to plug in a DMX terminator into the DMX OUT in last unit of
machine to improve signal reliability. Signal amplifier is required for long
distance (>200m) DMX signal transmission.
4. Power ON the DMX console and programming
Power on DMX console and program the uFlamer effect on DMX console
5. Test the ignition function of uFlamer
Test the ignition function of uFlamer, we can check whether the igniters of
each unit of uFlamer is working fine. Due to the safety switch is stay at TEST
MODE the pump won’t work, there will be only ignition while no fuel spray out,
so no flames generated.
6. Fill the uFlamer
Please fill the machine with qualified fuel. The fuels suggested on uFlamer
are ISOPAR, ISOPROPANOL, please make sure water content in fuel should less
than 0.5%.
7. Firing
a) Double confirm the prescribed safety isolation zone is clear, no person,
animal or other property within this region.
b) Switch the safety button of uFlamer to USER MODE.
c) Pressurize uFlamer.
d) Firing, the operator should always have a clear view of the device, so that
he/she can stop the show immediately when there is danger.
8. Depressurize
Depressurize all uFlamer after use or if not use for a long time during the
show we also suggest to depressurize to ensure the safety.
9. Power OFF
a) Power OFF DMX console
b) Switch safety switch of uFlamer to TEST MODE
c) Power OFF uFlamer
d) Unplug power cable, DMX cable.
Nozzles and Nozzle Replacement
Nozzles
There are two types of Nozzle for uFlamer. Nozzle M and Nozzle L. Nozzle M:
(standard configuration)
Short flame: 5-7m,
Long flame: 8-10m.
Nozzle L:
Short flame: 3-5m,
Long flame: 6-8m.
Nozzle Replacement
Use 14mm outer hexagon socket wrench to disassemble the nozzle, clean the
nozzle and nozzle socket with air gun (air compressor), change a different
nozzle and install it.
Igniter Position Adjustment
Whenever changed the nozzle or ignition is not good, please check igniter pole position according to below parameters. The right position for each pair of pole should have a gap from tip to tip of 4±0.5mm and a gap between two igniter of 13±1mm. Check the ignition success rate after adjustment by firing.
Note: Do unplug the power cable when service flamer.
Battery Recommendation
- Flamer can be driven by battery, you can order battery from us directly or buy it locally. The battery specifications are as below:
Capacity | 5200mah 20c-70c |
---|---|
Voltage | 14.8V |
Size | 1404344mm (LHW) |
Charge Jack | 2.54-5A |
Discharge Jack | XT60 |
Installation | Contact SHOWVEN sales for installation guide/video |
Maintenance
- To maintain the system in good performance and running status, it is recommended to running the device at least once per month.
- Check the ignition probes both before and after each show, if there is any foreign objects on it please clean it up.
- Maintenance of the nozzle: Nozzle needs to be cleaned from time to time, and it is recommended that once every six months (depending on the environment and frequency of use). In the process of using the equipment, if the flame shape is seriously deformed or the fuel injection line is significantly deformed or coarsened, the nozzle should be removed immediately for cleaning. If after clean, there are still problems please replace new nozzle.
- Maintenance of the O-ring: If it is found that the O-ring of the nozzle is damaged or ageing when cleaning the nozzle, the O-ring should be replaced in time (material and size of O-ring: fluororubber O-ring, the outermost diameter is 14 mm, and the line diameter is 2 mm).
Optional Parts for uFlamer
Part. No. | Description | pcs / unit |
---|---|---|
RMWAS025 | O ring for nozzle | 1 |
RMBOT036 | Safety ring | 1 |
RMMET045 | Safety rope | 1 |
RMEMD062 | Wireless receiver (for wireless control with FXcommander) | 1 |
SFSMA002 | nozzle M | 1 |
SFSMA003 | nozzle L | 1 |
SFMET944 | Nozzle disassemble tool | 1 |
RMSPS029 | 5500MAH 50C 14.8V 4S XT60 Lithium Battery | 1 |
SFCAB100 | Connection cable between RC battery charger and uFlamer | 1 |
RMEMD057 | HOT RC Lithium Battery Charger A400 | 1 |
RMCAB083 | EU power cord for HOT RC Charger A400 (For EU only) | 1 |
FPFLI026 | uFlamer Flightcase 2in1 | 1 |
SFCAB065 | Waterproof DMX cable, 6m | 1 |
Warranty Instructions
- Sincere thanks for your choosing our products, you will receive quality service from us
- The product warranty period is one year. If there are any quality problems within 7 days after shipping out from our factory, we can exchange a brand new same model machine for you
- We will offer free of charge maintenance service for machines which with hardware malfunction (except for the instrument damage caused by human factors) in warranty period. Please don’t repair machine without factory permission Below situations NOT included in warranty service:
- Damage caused by use unqualified fuels;
- Damage caused by improper transportation, usage, management, and maintenance, or damage caused by human factors;
- Disassemble, modify or repair products without permission;
- Damage caused by external reasons (lightning strike, power supply etc.)
- Damage caused by improper installation or use;
For product damage not included in warranty range, we can provide paid
service.
Invoice is necessary when applying for maintenance service from SHOWVEN
https://www.facebook.com/Showven-228026294663699/?modal=admin_todo_tour
Showven Technologies Co., Ltd.
Tel: +86-731-83833068
Web: www.showven.cn E-mail:
info@showven.cn
Add: Liuyang Economic Development Zone, Changsha, 410300, Hunan Province,
P.R.China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>