ARMSTRONG Astro 2 3-speed circulator models User Manual
- June 5, 2024
- ARMSTRONG
Table of Contents
ARMSTRONG Astro 2 3-speed circulator models
Motor data
model| electrical input| speed| full load
amp draw (a)
| nominal
power (w)
---|---|---|---|---
astro 210ci/ss
|
115v, 60hz
Single phase
| 3| 1.72|
200
2| 1.50
1| 1.06
Astro 220ssu
| 3| 0.29|
33
2| 0.27
1| 0.20
astro 225ssu
| 3| 0.69|
83
2| 0.55
1| 0.43
astro 230ss/ ci/ci-r| 3| 0.81|
97
2| 0.58
1| 0.45
Astro 250ss/ ci/ci-r| 3| 0.98|
117
2| 0.79
1| 0.65
Astro 280ci/ss
| 3| 1.90|
218
2| 1.80
1| 1.50
astro 290ci/ss
| 3| 1.90|
218
2| 1.60
1| 1.40
astro 280ci/ss 230v|
230v,60hz
Single phase
| 3| 0.90|
210
2| 0.86
1| 0.80
Astro 286ci/ss| 1| 1.60| 375
Technical data
- Max. fluid temperature: 185°f/85°c (Astro 286 up to 1.35a) 50°f/65°c (Astro 286 over 1.35a)230°f/110°c (all others)
- Max. working pressure: 150 psi / 1034 kPa Certification: ETL listed for the US and Canada (conforms to ul std.778 certified to CSA std. c22.2 no.108-01) NSF 372 (for stainless steel models)
Since water conditions can vary with geographical location (i.e. amount and type of dissolved solids) it is recommended that the operating temperature o the fluid for open (potable) systems be kept as low as possible (i.e. below 150°f or 65°c) to avoid precipitation of calcium.
Materials of construction
Pump body:
- Cast iron (closed system)
- Stainless steel** (open system)
Impeller: Noryl
Shaft: Ceramic
Bearings: Ceramic
Gasket: EPDM
Certified <0.25 weighted average percent lead (NSF 372) and complies with
California Health and Safety code section 116875 (commonly known as ab1953).
Dimensions and weights
**stainless steel*| | a| | b| | c| | d| e| f|
connection type & size| weight
---|---|---|---|---|---|---|---|---|---|---|---|---
Astro 220ssu| 6.00 (152)| 5.00 (127)| 4.00 (102)| —| 3.10 (79)| —| Union –
1¼” npsm| 6.5 (2.9)
Astro 225ssu| 6.00 (152)| 5.00 (127)| 4.00 (102)| —| 3.10 (79)| —| Union –
1¼” npsm| 6.5 (2.9)
Astro 230ss| 6.38 (162)| 6.00 (150)| 4.00 (102)| 4.00 (102)| 3.10 (79)| 3.25
(80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 250ss| 6.38 (162)| 6.00 (150)| 4.00 (102)| 4.00 (102)| 3.10 (79)| 3.25
(80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 210ss| 6.50 (165)| 7.25 (184)| 4.87 (124)| 4.00 (102)| 3.60 (91)| 3.13
(80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 280ss (230v)| 6.50 (165)| 6.75 (171)| 4.87 (124)| 4.00 (102)| 3.60
(91)| 3.13 (80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 286ss| 6.50 (165)| 6.38 (162)| 4.87 (124)| 4.00 (102)| 3.60 (91)| 3.13
(80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 290ss| 8.50 (216)| 6.65 (169)| 5.20 (132)| 4.00 (102)| 3.60 (91)| 3.45
(88)| Flange – (2) ½” dia. bolt holes| 13.2 (6.0)
cast iron| | a| | b| | c| | d| e| | f|
connection type & size| weight
Astro 230ci| 6.38 (162)| 6.00 (150)| 4.00 (102)| 4.00 (102)| 3.10 (79)| 3.25
(80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 230ci-r| 6.38 (162)| 5.63 (137)| 4.00 (102)| 4.00 (102)| 3.10 (79)|
3.25 (80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 250ci| 6.38 (162)| 6.00 (150)| 4.00 (102)| 4.00 (102)| 3.10 (79)| 3.25
(80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 250ci-r| 6.38 (162)| 5.63 (137)| 4.00 (102)| 4.00 (102)| 3.10 (79)|
3.25 (80)| Flange – (2) ½” dia. bolt holes| 8.0 (3.6)
Astro 210ci| 6.50 (165)| 7.25 (184)| 4.87 (124)| 4.00 (102)| 3.60 (91)| 3.13
(80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 280ci (230v)| 6.50 (165)| 6.38 (162)| 4.87 (124)| 4.00 (102)| 3.60
(91)| 3.13 (80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 286ci| 6.50 (165)| 6.38 (162)| 4.87 (124)| 4.00 (102)| 3.60 (91)| 3.13
(80)| Flange – (2) ½” dia. bolt holes| 10.1 (4.6)
Astro 290ci**| 8.50 (216)| 6.65 (169)| 5.20 (132)| 4.00 (102)| 3.60 (91)| 3.45
(88)| Flange – (2) ½” dia. bolt holes| 13.2 (6.0)
note: All dimensions are in inches (mm) and weights in lbs (kg).
- Certified <0.25 weighted average percent lead and complies with California Health and Safety Code Section 116875 (commonly known as ab 1953).
- Removable check valve installed at the pump outlet.
Cross-reference table
note: 1 Dimension and connection may vary.
- Flange orientation may vary.
- Supply voltage may vary.
- Connection with ½” sweat adaptor(s). 5 Connection with ¾” sweat adaptor(s).
- S1 Speed 1.
- S2 Speed 2.
- S3 Speed 3.
Performance curves
Astro 225ssu
buffalo: +1 716 693 8813
Bangalore: +91 80 4906 3555
Shanghai: +86 21 5237 0909
Armstrong fluid technology was established 1934
Documents / Resources
|
ARMSTRONG Astro 2 3-speed circulator
models
[pdf] User Manual
Astro 2, circulator, 3-speed circulator
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>