- Description: The 50L Mobile Parts Cleaning Tank is a high-quality product designed to provide trouble-free performance when used according to the provided instructions. It is manufactured to a high standard and is suitable for various cleaning applications.
Product Usage Instructions
Safety:
Electrical Safety:
- Before using the product, ensure that all electrical equipment and appliances are safe and in good condition.
- Inspect power supply leads, plugs, and connections for wear or damage.
- Sealey recommends using a Residual Current Device (RCD) with all electrical products.
- If the product is used for business duties, it must be maintained in a safe condition and routinely tested with a Portable Appliance Test (PAT).
- Ensure that the insulation on cables and the appliance is safe before connecting it to the power supply.
- Regularly check power supply cables and plugs for wear or damage and ensure secure connections.
- Use the correct voltage rating on the appliance and the appropriate fuse in the plug.
- Do not pull or carry the appliance by the power cable.
- Do not pull the plug from the socket by the cable.
- Do not use worn or damaged cables, plugs, or connectors. Repair or replace any faulty items immediately by a qualified electrician.
- If the cable or plug is damaged during use, switch off the electricity supply and remove it from use. Repairs should be carried out by a qualified electrician.
- When connecting the plug, follow the color coding: Green/Yellow wire to the earth terminal ‘E’, Brown wire to the live terminal ‘L’, and Blue wire to the neutral terminal ‘N’.
- Recommended fuse rating: 3 Amp.
- Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
- For cable extension reels, fully unwind before connection. It is recommended to use a reel with an RCD for additional protection.
General Safety:
- Always comply with Health & Safety, local authority, and general workshop practice regulations when using this equipment.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble-free performance.
IMPORTANT : PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
- Refer to instructions
- Wear eye protection
- Wear protective gloves
- Wear safety footwear
- Wear protective clothing
SAFETY
ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before use. Inspect power supply leads, plugs, and all electrical connections for wear and damage. Sealey recommends that an RCD (Residual Current Device) is used with all electrical products. You may obtain an RCD by contacting your local Sealey stockist. If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.
For electrical safety information, the following information must be read and understood:
Ensure that the insulation on all cables and the appliance is safe before connecting it to the power supply. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
Important : Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse – see fuse rating in these instructions.
- DO NOT pull or carry the appliance by the power cable.
- DO NOT pull the plug from the socket by the cable.
- DO NOT use worn or damaged cables, plugs, or connectors. Ensure that any faulty item is repaired or replaced immediately by a qualified electrician.
- This product is fitted with a BS1363/A 13 Amp 3-pin plug.
- If the cable or plug is damaged during use, switch off the electricity supply and remove it from use.
- Ensure that repairs are carried out by a qualified electrician.
- Replace a damaged plug with a BS1363/A 13 Amp 3-pin plug. If in doubt contact a qualified electrician.
- Connect the GREEN/YELLOW earth wire to the earth terminal ‘ E’.
- Connect the BROWN live wire to the live terminal ‘L’.
- Connect the BLUE neutral wire to the neutral terminal ‘N’.
- Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. Sealey recommends that repairs are carried out by a qualified electrician.
Cable extension reels
When a cable extension reel is used it should be fully unwound before
connection. A cable reel with an RCD fitted is recommended since any product
which is plugged into the cable reel will be protected. The section of the
cores of the cable is important and should be at least 1.5mm², but to be sure
that the capacity of the cable reel is suitable for this product and for
others that may be used in the other output sockets, we recommend the use of
2.5mm² section cable.
GENERAL SAFETY
- WARNING: Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
- Familiarise yourself with the applications, limitations, and potential hazards of the tank.
- WARNING : Disconnect the tank from the main power before changing accessories, servicing, or performing any maintenance.
- Replace or repair damaged parts. Use genuine parts only. Unauthorized parts may be dangerous and will invalidate the warranty.
- WARNING : DO NOT modify the lid or jam it open. Keep the lid and holding screws in place, tight, and in good working order.
- Locate the tank in a suitable work area and keep the area clean and tidy and free from unrelated materials. Ensure there is adequate lighting.
- Ensure there are no flammable or combustible materials near the work area.
- In case of fire in the tank, DO NOT attempt to move the unit or remove parts from the tank. The lid is fusible and will automatically close extinguishing fire.
- When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from closing fully if and when the fusible link activates.
- WARNING: DO NOT SMOKE and keep sources of ignition, such as heaters, lamps, etc., away from the unit, together with flammable or combustible materials, as there is an explosion risk.
- Use only water-soluble solvents.
- WARNING: When operating the tank always wear approved eye or face protection and appropriate protective clothing, including gloves, to prevent the cleaning agent from contacting the skin.
- Maintain correct balance and footing. DO NOT overreach. Ensure the floor is not slippery and wear non-slip shoes.
- Remove ill-fitting clothing. Remove ties, watches, rings, and other loose jewelry and contain and/or tie back long hair.
- ALWAYS concentrate on the job at hand, no matter how trivial it may seem. Be aware that accidents are caused by carelessness due to familiarity.
- Keep children and unauthorized persons away from the work area.
- Avoid unintentional starting. Ensure the switch is in the off position before plugging into main supply.
- DO NOT overfill the tank or allow fluid level to fall below the pump inlet.
- DO NOT use the tank for a task it is not designed to perform.
- DO NOT operate the tank if any parts are damaged or missing as this may cause failure and/or personal injury.
- DO NOT allow untrained persons to operate the tank.
- DO NOT operate the tank when you are tired or under the influence of alcohol, drugs, or intoxicating medication.
- DO NOT leave the tank operating unattended.
- When not in use switch off the tank, close the lid, and remove the plug from the power supply.
- Dispose of waste liquids by local authority regulations.
- WARNING: Protect the environment – DO NOT allow uncontrolled discharge of pollutants.
- Keep the tank clean for the best and safest performance.
INTRODUCTION
Heavy-duty one-piece tank. Fully sealed electric motor with magnetic drive pump unit. The lid features a self-latching fusible link which automatically snaps the lid shut in the event of a fire. Includes removable shelf and small parts basket. A flexible metal nozzle directs solvent over work. Supplied with workshop stand with integral storage shelf.
SPECIFICATION
- Model no: SM28.V2
- Maximum Working Capacity: 50L
- Minimum working Capacity: 40L
- Overall Dimensions (W x D x H): 775 x 540 x 960mm
- Pump Output/hr: 200L
- Supply: 230V
- Tank Dimensions (W x D x H): 775 x 540 x 265mm
ASSEMBLY
Refer to the attached Parts Diagram
- Remove parts from packing and take items out of the tank. Before assembly check parts to ensure they are complete and not damaged.
- Close the lid of the tank, gently and turn the unit upside down. Rest the tank on a clean soft surface (i.e. cardboard) ensuring the lid is secured in the closed position.
- Attach each of the 4 tank legs (13) with 4 sets each of 6mm screws, lock washers, and nuts (14,8,9) to the brackets on the tank (7) unit. Attach shelf (12) to holes located mid-way of 4 legs with 2 sets each of 6mm screws, lock washers, and nuts (14,8,9).
- Fit swivel castors, (37, 38) using nut and washer (40, 39).
- Return the tank unit to the upright position on its legs and open the spring tensioned tank cover (1).
- Thread the fitting of the flexible metal pipe (24) fluid outlet tube onto the pump elbow (13), fig.1. Place the pump housing lid (29) over the open pump housing (20) with fluid intake perforations and raised ribs downward and over pump fig.2. Snap into place.
- Route the power cord of the pump housing assembly through the rectangular opening on the side of the tank unit (7) with the inlet filter (28) downward and facing inward, fig’s.3 & 4.
- The power switch is visible through the rectangular opening. Hook the raised offset tab on the rear of the pump housing (20) over the bottom edge of the rectangular opening Fig. 4.
- Check to see that the tank plug (11) plug is tightly installed.
- Place the work shelf (6) over the edges of the walls of the tank (7).
- Make sure the nozzle of the flexible pipe (24) is facing in toward the center of the tank (7) and downward.
- Installation of a flow-through parts cleaning brush and hose extension is optional.
- Fill the unit with a suitable, water-based degreasing solution sufficiently to cover the entire inlet filter (28) (approx.12 gallons).
- Important Note: Follow degreasing solution mixing, usage, and safety label instructions carefully before using.
- Plug the power lead into a mains supply.
- Turn the Power Switch to the “On” position.
OPERATION
WARNING :
Wear safety clothing, eye protection, and gloves and ensure you read,
understand and apply the safety instructions in Section 1.
- Ensure the unit is located on a firm-level surface in a well-ventilated area and is switched off and unplugged from the mains power supply.
- Fill the tank with Sealey solvent – approx. 50 liters. The minimum level must cover the pump inlet – approx. 40 liters. Follow the solvent instructions on the packaging.
- DO NOT fill with flammable solvents such as paraffin, thinners, etc.
- Open the lid, switch the pump on, and hold the part to be cleaned under the nozzle, slowly rotate the component until clean.
- DO NOT leave the unit operating unattended.
- When clean, leave to drain on the tray or in a small component container until dry.
- When cleaning is complete remove all parts whilst ensuring the minimum of cleaning agent spillage.
- Switch off the pump and close the lid and disconnect the power supply.
- Note : Any spillages should be mopped up immediately, so as not to cause a safety hazard. Dispose of waste liquids by local authority regulations.
- IMPORTANT : The safety lever (4,5) incorporates a safety device in the form of a fusible link, which closes the lid in the event of a fire. The link is non-resetting and must be replaced should it be activated.
- DO NOT prop the lid open as this will prevent the automatic safety feature from operating.
- When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from closing fully if and when the fusible link activates.
MAINTENANCE
- Clean the pump filter regularly, by sliding it away from the pump housing and rinsing it in a clean degreaser.
- DO NOT allow the level of liquid in the parts washer to fall below the pump inlet, as damage to the pump can result. CLEAN, L
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the
EU Directive on Waste Electrical and Electronic Equipment (WEEE). When the
product is no longer required, it must be disposed of in an environmentally
protective way. Contact your local solid waste authority for recycling
information.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools,
accessories, and packaging should be sorted, taken to a recycling center, and
disposed of in a manner that is compatible with the environment. When the
product becomes completely unserviceable and requires disposal, drain any
fluids (if applicable) into approved containers and dispose of the product and
fluids according to local regulations.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications, and parts without prior notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call our technical team at technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: The guarantee is 12 months from the purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
- 01284 757500
- 01284 703534
- sales@sealey.co.uk
- www.sealey.co.uk
© Jack Sealey Original Language Version Limited SM28.V2 Issue:1 21/06/22