ATTENTION: Please read all instructions BEFORE installation
- Product to be installed by a licensed electrician – Field modifications void warranty
- Use only with Class 2 power supply unit — Compatible for use with Q-Tran power supplies
- Surface mount or recessed in millwork
- Not rated for walkover
- Input Voltage: 24VDC
- Diagrams for representation only and not to scale.
METHODS OF INSTALLATION
Mounting Method
- WSC (page 6)
- MC (page 7)
- PPS-LP-CL-2 (page 8)
- PPS-LP-CL-96 & PPS-LP-CL-FT (page 9)
Cove, Under & over cabinet:
Ideal for office, retail, hospitality, education, laboratory, and residential.
Shelf:
Ideal for office, retail, hospitality, education, laboratory, and residential.
Display cabinet:
Ideal for retail and hospitality
Signage:
Ideal for lobby, retail, hospitality, institutional, and transportation.
COMPONENTS & HARDWARE
MOUNTING CLIP & MOUNTING CHANNEL
WSC
| MC
|
White snug clip
| Magnetic clip (Cove use only)
Included|
Included
- #6 Flat Screw (one provided for each clip)
|
-
6 Flat Screw (one provided for each clip)
SEAMLESS MOUNTING CLIP & SEAMLESS MOUNTING CHANNEL
PPS-LP-CL-2
| PPS-LP-CL-96| PPS-LP-CL-FT
| |
Low profile PVC mounting clip
| Low profile PVC channel|
Low profile PVC channel
Included
|
Included
|
Included
-
8 flat head screw (1 screw for every 16”)
- No wireway
|
- #8 flat head screw (1 screw for every 16”)
- No wireway
|
-
8 flat head screw (1 screw for every 16”)
- No wireway
- Custom length
ACCESSORIES SOLD SEPARATELY
Q-ANGLE; sold in pairs
Q-ANGLE
Included
- 4 SS #6×1.25” Flat head wood screws
- 2 SS 4-40 Flat head clip screws
- 2 SS 6-32 Fillister screws
NOTES:
MOUNTING CLIP
|
SEAMLESS CLIP
- 2 white snug clips provided per first 12”, 1 for each additional 12”. Other mounting styles incur additional charge, see price guide for details
|
- PPS-LP-CL-2to join two fixtures together
- PPS-LP-CL-96/FT to support the fixtures
- PPS-LP-CL-FT is to be cut at Q-Tran to requested length
CONTINUOUS WIRING CONFIGURATION OPTIONS
Review wire method to ensure clean installation prior to mounting finished fixture.
NOTE: Additional wire methods include:
S1: Connector/Wire Input only
P1: Connector/Wire Input and Output
SURFACE MOUNTING METHOD
SURFACE PREPARATION
-
Temperature and environmental concerns
• Ideal application environment is 70-100ºF in 50% humidity or less.
• Minimum application temperature: 50ºF
• This temperature and humidity should be maintained for 72 hours after application for maximum holding force.
-
Using a 50/50 alcohol mix, thoroughly clean the backside of the fixture and the surface area where fixture will be installed. Allow 5 minutes to dry.
-
Using a 50/50 alcohol mix, thoroughly clean the backside of the fixture and the surface area where fixture will be installed. Allow 5 minutes to dry.
MATERIALS | SUGGESTED EPOXIES |
---|---|
Concrete, Stone, Cinderblock, Metal, and Brick | Loctite Metal and Concrete |
Two-Part Epoxy
BS, Fiberglass, Plastic, and PVC| Loctite Plastic Two-Part Epoxy
Tile, Wood, Ceramic, Glass, or Metal| Loctite Clear Two-Part Epoxy
All Purpose| Strong Stik
SURFACE MOUNTING METHOD: WHITE SNUG CLIP
- 2 clips provided per first 12”, 1 for each additional 12”
-
Determine the fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 12”.
-
• Secure clips using the #6 flat head hardware provided
• Ensure the screw head is flush with the clip’s base.
-
Snap fixture onto clips.
MOUNTING METHOD: MAGNETIC CLIP
- 2 clips provided per first 12”, 1 for each additional 12”
-
Determine the fixture(s) location and positioning on desired surface; evenly distribute clips. Make any necessary reference markings to indicate where each clip is to be secured in place. Recommended every 12”.
-
Attach clips to fixture matching magnet distances.
NOTE: Flat head screw type is dependent on surface/application material.
Alternative flat head screws may be required. Refer to the surface material manufacturer for suggested screw type.
-
Align and snap fixture to magnetic rings.
SEAMLESS MOUNTING METHOD: PPS-LP-CL-2
- Connects two fixtures, with no wire exit
- 2” low profile PVC mount channel
-
Snap in 2” channel.
-
Press fixture into mounted PPS channel.
-
Finished assembly for end feed mounting
SEAMLESS MOUNTING METHOD: PPS-LP-CL-96 / PPS-LP-CL-FT
- Support two fixtures, without built-in wireway
- 96” (PPS-LP-CL-96) or custom length (PPS-LP-CL-FT)low profile PVC mount channel
-
The PPS-BRACKET can be field cuttable and cut to whatever length your application requires. The PPS-BRACKET can be installed as a full length of 96”, multiple smaller pieces, or end to end for longer seamless runs.
Using pre-drilled pilot holes screw the #8 flat head screws to mount the PPS- BRACKET (1 screw every 16”).
NOTE: For drywall applications mount directly into a stud.
-
Using pre-drilled pilot holes, use the #8 flat head screws to mount the PPS-BRACKET.
-
To mount, pinch the upper half of the PPS-LP-CL-96 or PPS-LP-CL-FT while you pivot it around one side of the PPS-BRACKET and push-in until you hear it snap into place. The PPS-LP-CL-96 or PPS-LP-CL-FT flexes around the PPS-BRACKET to create a solid, and secure snap on connection
Customer Support
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 |203-367-8777 | sales@q-tran.com | www.q-tran.com Specification subject to change. Rev-05-05-23 9
References
- Your Name as Your Email | Hover Realnames
- LED Lighting Systems, Linear LED Lights, LED transformers | Q-Tran
- LUME-01 | LUME | Q-Tran
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>