Thank You
Thank you for choosing OTO product to complement your healthcare needs. All OTO products have been tested and confirmed safe and reliable for personal use. Please read the user manual carefully to understand the correct usage and operations.

SAFETY PRECAUTIONS

  1. People with the following conditions should consult their physician before using the product:
    • Who uses a medical electronic device which is embedded in the body such as a pacemaker.
    • Who suffers from heart disease.
    • Who suffers from neck, backbone injury or disease.
    • Who is suffering from bone fragility, especially on the backbone.
    • After surgery.
    • Who is pregnant or shortly after delivery or in a period of monthly illness.
    • Who suffers from malignant tumors.
    • Who is suffering from blood circulation problems or thrombosis.
    • Who is suffering from skin disease or infection.
    • Who is undergoing medical treatment or feels some physical abnormality previously or is being treated now.
    • Who has injuries, diseases due to illness or accident.
    • Who has some abnormality or deformity of limbs or backbone.

  2. Do not let water enter the product or be splashed near the surface of the product.

  3. Water contact with electricity is dangerous. Do not leave the product in a humid environment ( such as in the bathroom or shower room or next to swimming pool).

  4. Before connecting the product to the power supply, check that the product voltage and supply voltage are the same.

  5. If the plug, power cord or product itself is damaged, do not use the product.

  6. In order to prevent the risk of electric shock, do not open the product cuter cover.

  7. Product is not intended for use by the disabled, sensory or mentally impaired persons (including children), unless there is supervision or guidance by the people responsible for their safety when they use the product.

  8. If the product or the power cord is damaged, do not try to repair the product. This must be handled by OTO technician or the product guarantee will become void.

  9. Children should not use this product. They should be under supervision to ensure that they will not treat this product as a toy.

  10. If an unusual sound or noise is being heard from the product, tum off the product and immediately disconnect the power connection. Please contact OTO or its authorised dealers immediately.

  11. Do not use the product if cover is damaged or if there is a mechanical or electronic failure. Please contact OTO or its authorised dealers.

  12. Only use or place the product in accordance with the instructions in this user manual.

  13. Do not use this product in high temperature conditions or beside hot objects such as heaters, stoves.

  14. Do not apply medical or cosmetic cream on the product or on your body before using or during the use of this product.

  15. Do not destroy, bend, stretch, twist or tie the power cord. Damaged power cord can cause fire or electric shock.

  16. Recommended usage time for an individual is 10 minutes at a time.

  17. Please remove all accessories on body before use.

  18. This product is intended for household use only.

  19. Do not use the product while sleeping, when drunk, or during a fever.

  20. Avoid using the product immediately after eating. Wait for at least an hour before using the product.

  21. Do not use the product on bare skin.

  22. When massaging, refrain from using excessive intensity. Do not use the product on inflammed or bruised parts of the body.

  23. Do not stand on the product. The product should only be used while seated.

  24. When moving the product from a cool place to a warm place or vice versa, wait for about an hour before use. The quick change in temperature may result in the liquefied vapours to get in contact with the product, thereby causing it to lose its optimal functionality.

  25. Please do not use the product if you are using any one of the following devices:
    • Internal medical products such as a pacemaker.
    • Biological products such as a mechanical heart or lung.
    • Attachable medical products such as electrocardiograph.

  26. Please refrain from excessive use of the product on sensitive skin. Do not use the product on an open wound or wounded area unless permitted by a doctor/physician.

  27. Please make sure the product is turned off before starting to use it.

  28. Complete the treatment with a glass of warm water to help in detoxification.

  29. A minority of users with sensitive skin may experience irritation or rashes after therapy. This is a temporary phenomenon that will pass after a few sessions. It will not reappear after the skin has acclimatized to the electro stimulation therapy.

Electromagnetic fields (EMF) This OTO product complies with all standards regarding electromagnetic fields (EMF). If handled properly and according to the instructions in this user manual, the product is safe to use.

PREPARATIONS FOR USE

  1. Remove loose articles from leg or body that will be in contact with the product.
  2. Rest your feet gently on the product before selecting the programme and intensity.
  3. Do not use the product within 1 hour after meal.
  4. For users who have drier skin or sensitive skin due to medical condition such as diabetes, it’s advisable to apply body lotion or wipe the body part with a damp cloth to moisturize the skin before use.

PRODUCT DESCRIPTION

Main Body & Accessories

  1. Main Body
  2. Foot Pad
  3. EMS Control Panel
  4. Remote Controller
  5. USB Cable
  6. USB Port
  7. LED Indicator

OTO EM 850 Wireless E Mag Device - Product description

EMS Control Panel

  1. USB Port

  2. Intensity display

  3. Mode LED indicator

  4. Power Button: Press for 2 seconds to turn on the product; press for 2 seconds to turn off.
    Mode Button: Press to enter and select auto programmes (3 modes).

  5. Intensity Button: Press corresponding “ ” or “ ” button to select the intensity level (1-10 levels).

Remote Controller

  1. Power Button: Press once to turn off the product. (This remote cannot turn on the product. This remote could be activated by pressing any key on it when EMS control panel is powered on.)
  2. Mode Button: Press to enter and select auto programmes (3 modes).
  3. Intensity Button: Press corresponding ” + ” or ” — ” button to select the intensity level (1-10 levels).

HOW TO OPERATE

Remote Controller

  • In order to prevent battery consumption, there is insulation between the battery and the battery cover. Please pull out the insulation before use.
  • Open the battery cover, then pull out the insulation sheet according to the direction of the arrow.
  • One battery is included.

Main Body
OTO EM 850 Wireless E Mag Device - Main Body

  • Install the EMS control panel on the main body correctly, put the feet on the main body (bare feet).

Note:

  1. Please wipe off dirt on the product (dust, sebum, etc.) before use. It may not conduct normally if the conductive part (foot shape) is dirty.
  2. Please stop using and contact OTO or its authorised dealers if EMS control panel is faulty.

EMS Control Panel Operation

  • Press and hold power button for 2 seconds on control panel to power on.
  • Default is Mode 1 (Low-Frequency + Intermediate-Frequency Mixed Mode) and intensity level 1.
  • The panel will auto turn off after 10 minutes.

OTO EM 850 Wireless E Mag Device - Control panel
operation Mode Seection OTO EM 850 Wireless E Mag Device - Mode SelectionIntensity SelectionOTO EM 850 Wireless E Mag Device -
Intensity selection Intensity can be adjusted through the buttons (1~10 levels). Please start from intensity level 1 for new users.

Rack OperationOTO EM 850 Wireless E Mag Device - Rack
Operation Angle (Height) Adjustment

  1. Pull out the angle adjustment rod on the main body back as below figure. (Please refer to “Angle 1 Operation” for Angle 1 Low Height, and “Angle 2 Operation” for Angle 2 High Height as shown in below pictures.
  2. Pull out the adjusting rod and lift the support until it can no longer be moved.
  3. Please return the adjusting rod to its original position after use.

OTO EM 850 Wireless E Mag Device - Adjustment

Note:

  1. Do not operate with brutal force.
  2. Excessive force or over-load may cause product damage.

CARE & MAINTENANCE

Cleaning

  1. Do not use steel wool, abrasive cleaning agents or corrosive liquids(such as gasoline or acetone) to clean the product.
  2. Unplug the plug from the power socket.
  3. Wipe with a dry cloth to clean the product, control panel and power cord.
  4. Do not use a damp cloth or detergent.

Storage

  1. Unplug the plug from the power socket.
  2. Store the product in a cool dry place away from sunlight.
  3. Do not put a heavy weight load on the product.

If the cover is damaged or there is any mechanical failure, please stop using the product. Contact OTO or its authorised dealers immediately.

PRODUCT SPECIFICATIONS

Name of Product OTO E-Mag
Model Number EM-850
Type of Product Massage Equipment
Rated Voltage 5V / 1A
Power Consumption <0.5W
Intensity Levels 10
Automatic Programmes 3
Auto Timer 10 mins
Main Body Dimensions Approx. 330 (L) x 300 (W) x 20 (H) mm
EMS Control Panel Dimensions Approx. 43 (L) x 120 (W) x 25 (H) mm
Remote Controller Dimensions Approx. 40 (L) x 86 (W) x 7 (H) mm
Box Dimensions Approx. 380 (L) x 75 (W) x 365 (H) mm
Max Loading Capacity Approx.100 kg
Net Weight Approx. 1.4 kg
International Safty Compliance CE

Copyright
Al Rights Reserved. No part of the content in this manual may be reproduced, stored, transferred, distributed, translated in any form or by any means without prior written permission from OTO.

OTO logowww.otobodycare.com