Specifications

  • Model : SPC-100
  • Operating Voltage : Unspecified
  • Current Consumption : Unspecified
  • Operating Principle : Unspecified
  • Measurement Particle Size Range : 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 um
  • Measurement Range : Unspecified
  • Counting Efficiency : Unspecified
  • Temperature Measuring Range : Unspecified
  • Humidity Measuring Range : Unspecified
  • Wi-Fi Output Protocol : Modbus RTU
  • Digital Output : RS485
  • RF Frequency Bands : WLAN – 2412-2472 MHz / BLE – 2402-2480 MHz
  • Maximum RF Output Power : WLAN – 19.8 dBm / BLE – 9.8 dBm
  • Operating Temperature: 10°C to +60°C
  • Storage Temperature: 0°C to +70°C
  • Dimension (WHD): 11018544.3 mm (Wi-Fi Without Antenna)
  • Weight: 387g

Product Usage Instructions

Operating Configuration
The SPC-100 has several operating configurations that can be accessed through the control buttons:

  • UP KEY : Move up and increase value

  • DOWN KEY : Move down and decrease value

  • MENU KEY : Enter configuration mode

  • ENTER KEY : Confirm selection/enter configuration

  • Configuration Mode
    The configuration mode allows you to access different settings on the SPC-100. To enter configuration mode, click the MENU button.

  • Sensor Display Settings
    The sensor display settings allow you to configure the particle size range displayed on the initial screen. To enter sensor display settings, click the ENTER button when in configuration mode.

  • Equipment Settings
    The equipment settings allow you to configure various options related to the equipment. This includes language settings, equipment ID, baud rate, and temperature unit. To enter equipment settings, click the ENTER button when in configuration mode.

  • Sensor Alarm Settings
    The sensor alarm settings allow you to set alarms for each particle size range. This includes upper and lower limits for each size range. To enter sensor alarm settings, click the ENTER button when in configuration mode.

  • Wi-Fi Settings
    The Wi-Fi settings are required for Wi-Fi communication. This includes configuring the AP IP addresses. To enter Wi-Fi settings, click the ENTER button when in configuration mode.

Frequently Asked Questions (FAQ)

  1. Q: What is the operating voltage of the SPC-100?
    A: The operating voltage is unspecified in the user manual.

  2. Q: What is the current consumption of the SPC-100?
    A: The current consumption is unspecified in the user manual.

  3. Q: What is the measurement range of the SPC-100?
    A: The measurement range is unspecified in the user manual.

  4. Q: What is the counting efficiency of the SPC-100?
    A: The counting efficiency is unspecified in the user manual.

  5. Q: What is the temperature measuring range of the SPC-100?
    A: The temperature measuring range is unspecified in the user manual.

  6. Q: What is the humidity measuring range of the SPC-100?
    A: The humidity measuring range is unspecified in the user manual.

Product Overview

Characteristic

  • Real-time particle monitoring and control
  • Precision measurement and long-term stability
  • IGS-SPC-100-Industry-Gas-Spring-IMAGE-11
  • 268 * 128 mono graphic LCD applied
  • Simultaneous display of particle, temperature and humidity measurements
  • RS485 communication (Modbus RTU)
  • Wi-Fi communication Station Mode : TCP/IP, Wi-Fi(2.4GHz) communication support

Applications

  • Semiconductor cleanroom particle, temperature, humidity measurements
  • Particle, temperature and humidity measurement in pharmaceutical and hospital cleanroom
  • Various semiconductor equipment
  • IAQ (Indoor Air Quality) monitoring and control device for home and industrial
  • Home and industrial air conditioner

Specifications

Model SPC-100
Operating Voltage 12Vdc ±10% (DC Adapter plug: inner diameter 2.1, outer

diameter 5.5PIE)
Current consumption| Max. 350mA @ 12Vdc
|
Operating principle| Laser scattering
Measurement particle size range| >0.3㎛, >0.5㎛, >1.0㎛, >2.5㎛, >5.0㎛, >10㎛
Measurement range| 0 ~ 10,000,000 pcs/L (1pcs/L = 28.3pcs/cf)
Counting efficiency| ≥50%@0.3μm , 100%@>0.5μm ( 0°C ~ 40°C, 50 ±10%RH )
|
Temperature measuring range| -40 ~ +125℃ / ±1℃
Humidity measuring range| 0 ~ 100% / ±5.0%
|
Wi-Fi output Protocol| Station Mode (TCP/IP Communication)
Digital Output| RS485 Modbus
|
RF frequency bands| WLAN: 2412-2472 MHz / BLE: 2402-2480 MHz
Maximum RF output power| WLAN: 19.8 dBm / BLE: 9.8 dBm
|
Operating Temperature| 10… +60℃
Storage Temperature| 0… +70℃
|
Dimension ( WHD)| 11018544.3 (Wi-Fi Without Antenna)
Weight| 387g

Product Function and How To Use

Operating configuration

IGS-SPC-100-Industry-Gas-Spring-IMAGE-1

Configuration Mode

Click the MENU button to enter configuration mode.

  1. Sensor Display Settings
    Particle size range setting displayed on the initial screen

  2. Equipment Settings Equipment
    Default Settings.

  3. Sensor Alarm Settings
    Set an alarm for each Particle Size Range.

  4. Wi-Fi Settings
    Settings required for Wi-Fi communication.

Sensor Display Settings

IGS-SPC-100-Industry-Gas-Spring-IMAGE-3

  • Click the ENTER button to enter Sensor Displays Settings.
  • Particle size range setting displayed on the initial screen

Equipment Settings

IGS-SPC-100-Industry-Gas-Spring-IMAGE-4

  • Click the ENTER button to enter Equipment Settings.
  • Equipment  Default Settings.

Sensor Alarm Settings

IGS-SPC-100-Industry-Gas-Spring-IMAGE-5

  • Sensor Alarm Settings
  • Set an alarm for each Particle Size Range.

Wi-Fi Settings

IGS-SPC-100-Industry-Gas-Spring-IMAGE-6

  • Click the ENTER button to enter Wi-Fi Settings.
  • Settings required  for Wi-Fi communication.

When using Wi-Fi mode, RS485 communication is not available.

Connector Specifications

IGS-SPC-100-Industry-Gas-Spring-IMAGE-7

Communication Connector Pin Map Specification

IGS-SPC-100-Industry-Gas-Spring-IMAGE-8

Product Appearance

Product Dimensions

IGS-SPC-100-Industry-Gas-Spring-IMAGE-9IGS-
SPC-100-Industry-Gas-Spring-IMAGE-12

Products handling precaution

  • There is a risk of electric shock to this product, so do not open the product while power is applied.
  • Be sure to install this product on a fixed location such as a rack or panel.
  • Do not touch the power plug with wet hands. It may cause electric shock or injury.
  • Supply the power input within the specified rating range.
  • Be careful not to let water or beverages enter the product.
  • Clean regularly with a soft cloth or brush. If the dust inlet and outlet are blocked, it may cause product failure.
  • To prevent inductive noise, separate wiring from high-voltage lines and power lines.
  • Avoid installation in places subject to strong magnetism, noise, vibration and impact.
  • When extending the sensor wire, use a shield wire and do not make it unnecessarily long.
  • Sensor wire and signal wire should be wired independently away from power, power and load wires.
  • Avoid using near devices that generate strong high-frequency noise (high-frequency welding machine, high-frequency sewing machine, high-frequency radio, large-capacity SCR controller).
  • Some measurement errors may occur depending on the usage environment and usage method.
  • Do not disassemble the product arbitrarily. (Warranty does not apply to products that have been disassembled.)
  • We are not responsible for product damage outside of the warranty conditions specified by the manufacturer.
  • It is recommended to calibrate once a year because it can be affected by factors such as temperature, humidity, and shock during the long-term use period.
  • Be sure to observe the contents specified in the handling precautions above as they may cause product failure.
  • The specifications and dimensions described in this user manual are subject to change without notice for improvement.

FCC Instructions

FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

FCC Caution
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

FCC Radiation Exposure Statement
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.

  • This document contains information of products and processes in development. All information provided here is subject to change without notice. Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
  • We do not guarantee the performance of this device in case of disassembling, operating without complying with instructions in this document.
  • Contact your IGS representative to obtain the latest forecast, schedule and specifications. Or It may be obtained by calling +82-2-6299-7536~7 or by visiting http://www.igstech.kr

Copyright © 2023 IGS Incorporated. All rights reserved.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals