OTO JC-100 Joint Care User Manual

June 12, 2024
OtO

JC-100 Joint Care
User Manual

Thank You
Thank you for choosing OTO product to complement your healthcare needs. All OTO products have been tested and confirmed safe and reliable for personal use. Please read the user manual carefully to understand the correct usage and operations.
Copyright
All Rights Reserved. No part of the content in this manual may be reproduced, stored, distributed, or translated in any form or by any means without prior written permission from OTO.

SAFETY PRECAUTIONS

  1. People with the following conditions should consult their physician before using the product:
    • Who uses a medical electronic device which is embedded in the body such as a pacemaker.
    • Who suffers from heart disease.
    • Who suffers from neck, backbone injury or disease.
    • Who is suffering from bone fragilty.
    • After surgery.
    • Who is pregnant or shortly after delivery or in a period of monthly illness
    • Who suffers from malignant tumors.
    •  Who suffers from osteoporosis.
    • Who is suffering from blood circulation problems or thrombosis.
    • Who is suffering from skin disease or infection.
    •  Who is undergoing medical treatment or feels some physical abnormality previously or is being treated now.
    • Who has injuries, diseases due to illness or accident.
    • Who has some abnormality or deformity of limbs.

  2. Do ot let water enter the product or be splashed near the surface of the product.

  3. Water contact with electricity is dangerous. Do not leave the product in a humid environment ( such as in the bathroom or shower room or next to swimming pool)

  4. Before connecting the product to the power supply, check that the product voltage and supply voltage are the same.

  5. If the plug, power cord or product tself is damaged, do not use the product.

  6. In order o prevent the risk of electric shock, do not open the product cuter cover.

  7. Product s not intended for use by the disabled, sensory or mentally impaired persons (including children), unless there is supervision or guidance by the people responsible for their safety when they use the product.

  8. If the product or the power cord is damaged, do not try to repair the product. This must be handled by OTO technician or the product guarantee will become void.

  9. Children should not use this product. They should be under supervision to ensure that they will not treat this product as a toy.

  10. If an unusual sound or noise is being heard from the product, tum off the product and immediately disconnect the power connection. Please contact OTO o ts authorised dealers immediately.

  11. Do not use the product f cover is damaged o if there is a mechanical or electronic failure. Please contact OTO or its authorised dealers.

  12. Only use or piace the product in accordance with the instructions in this user manual.

  13. Do not use this product in high temperature conditions or beside hot objects such as heaters, stoves.

  14. Do not apply medical or cosmetic cream on the product or on your body before using or during the use of this product.

  15. Do not destroy, bend, siretch, twist o tie the power cord. Damaged power cord can cause fire or electric shock.

  16. Recommended usage time for an individual is 20 minutes at a time.

  17. Please remove all accessories on body before use.

  18. This product is intended for household use only.

  19. Do not use the product while sleeping, when drunk, or during a fever.

  20. Avoid using the product immediately after eating. Wait for at least an hour before using the product.

  21. When massaging rofain rom using excassive ntensiy. Do notuse the prodcton inflammed or bruised parts of the body.

  22. Please do not use the product if you are using any one of the following devices:
    • Internal medical products such as a pacemaker.
    • Biologicalproducts such a3 8 mechanical heart or lung,
    • Attachable medical products such as electrocardiograph.

  23. Please refrain from excessive use of the product on sensitive skin. Do not use the product on an open wound or wounded area unless permitted by a doctor.

  24. Please make sure the product is turned off before starting to use it

  25. Complete the treatment with a glass of warm water to help in detoxification.

  26. A minority of users with sensitive skin may experience iritation or rashes after therapy. This is a temporary phenomenon that will pass after a few sessions. It will not reappear after the skin has acclimatized to the electro stimulation therapy.

  27. Do not use the product when the room temperature is above 104 F or 40 C

Electromagnetic felds (EMF)
This OTO product complies with all standards regarding electromagnetic fieids (EMF).
If handled properly and according to the instructions in this user manual, the product is safe to use.

PRODUCT DESCRIPTION

Main Body & Accessories

  1. Knee Brace * 1 pc
  2. EMS Control Panel * 1 pe
  3. Electrode * 4 pcs
  4. USB Cable * 1 pcOTO JC-100 Joint Care - discription

EMS Control Panel

  1. LED indicator

  2. Intensity Decrease (-) Button (1~10 levels).

  3. Power Button (t): Press for 2 seconds to tur on the product; press for 2 seconds to turn off.
    Mode Bution: Press to enter and select auto programmes (3 modes).

  4. Intensity Increase (+) Button (1~10 levels).OTO JC-100 Joint Care - control panel

Knee Brace
1.4 Conductive Areas   OTO JC-100 Joint Care - discription
2

PREPARATION FOR USE

  1. Remove loose articles from leg or body that will be in contact with the product,
  2. Wrap the product round your knee before selecting the programme and intensity.
  3. Do not use the product within 1 hour after meal.
  4. For users who have drier skin or sensitive skin due to medical condition such as diabetes, it’s advisable to apply body lotion or wipe the body part with a damp cloth to moisturize the skin before use.

Knee Brace and Electrode

  1. Peel off plastic protector from one side of the electrode.

  2. Stick to the correspond conductive areas at the back side of the product. Total 4 conductive areas need electrodes.

  3. Peel off the plastic protector, and keep it properly.

  4. Puton the knee brace onto the knee tightly.
    OTO JC-100 Joint Care - discription 6

  5. Connect the EMS control panel to the brace. OTO JC-100 Joint Care - discription 7

HOW TO OPERATE

EMS Control Panel Operation

  • Press the Power Button (w) for 2 seconds on control panel to turn on the product.
  • Defaultis Mode 1 and intensity level 1.
  • The panel wil auto turn off after 20 minutes.
  • Intensity Button: Press corresponding + ” or- * button to select the intensity level (1-10 levels)

To Charge

  • Connect USB cable to the product and the power source.
  • During charging, the Power Button indicator light is red and keeps flash. It will stay on after battery i fully charged.
  • The product cannot operate while charging. It can only operate again when itis disconnected from power source.

CARE & MAINTENANCE

Cleaning

  1. Do not use steel wool, abrasive cleaning agents o corrosive liquids (such as gasoline or acetone) to clean the product.
  2. Unplug from the power source.
  3. Wipe with a dry cloth to clean the product and control panel.
  4. Do not use detergent
  5. Keep the product in the box provided.
  6. Electrodes must always be covered with the plastic protector after use.
  7. Al accessories must be keptin a proper place.

Storage

  1. Unplug from the power source.
  2. Store the product in a cool dry place away from sunlight
  3. Do not put a heavy weight load on the product
  4. Put the plastic protector on the electrodes after use, and do not allow the electrodes to touch each other.

TROUBLE-SHOOTING

This page summarizes the most common problems you could encounter with the product . If you are unable (o solve the problem with the information below, contact OTO or its authorised dealers immediately.

Problem Possible Cause Suggestion
Device does not switch on Battery drained Charge the battery
Abnormal shutdown Battery drained Charge the battery
Weak intensity Low intensity Pressthe + or- button b adjust the intensity
Battery drained Charge the battery
Cannot be charged Wrong voltage Please make sure the Output Voltage is DC

5V/1A and in normal working condition
Problems that may be encounterd during use| Poor viscosity| Attach the electrodes to your flat skin part. If the viscosity of electrodes fades away, use purified water to dean it, and let it dry naturally
Sting feeling during massage| If there is a tingling feeling every time you use the product, please adjust the strength that suits you

PRODUCT SPECIFICATIONS

Name of Product OTO Joint Care
Model Number JC-100
Type of Product Knee Therapeutic Massager
Rated Voltage 5V / 1A
Power Consumption <0.5W
Intensity Levels 10
Automatic Programmes 3
Auto Timer 20 mins
Main Body Dimension Approx. 575 (L) x 238 (W) mm
EMS Control Panel Dimension Approx. 54 (L) x 44 (W) x 15 (H) mm
Box Dimension Approx. 40 (L) x 86 (W) x 7 (H) rrim
Net/Gross Weight Approx. 0.18kg / 0.28kg
International Safety Compliance CE

www.otobodycare.com

Read User Manual Online (PDF format)