acaia PS001 Pearl Model S Coffee Scale User Manual

June 12, 2024
acaia

acaia PS001 Pearl Model S Coffee ScaleAcaia Pearl Model S
User Manual
PS001 / PS002

In the Box

Introduction
Thank you for choosing one of our scales. The Acaia Pearl Model S is designed and manufactured to the most rigorous standard to give you the best coffee brewing experience.
First, check the shipping carton to find the following:acaia PS001 Pearl
Model S Coffee Scale - Box

Next, follow the instructions in the “Getting Started” chapter in this manual to start using your scale. To take full advantage of the many features of the Pearl Model S, carefully read through this user manual for step-by-step procedures,  examples, and other information.
Warning: Incorrect handling of this product could result in personal injury or physical damage.

Scale Overview

acaia PS001 Pearl Model S Coffee Scale - Overview

*Note: For the best performance, place the weight in the center of the weighing pan.

Getting Started

Placement

Select a work surface that is stable, vibration-free and level to place the scale.

Power On / Off

[Press] to turn on the scale.
[Double tap] to turn off the scale.

Tare Weight
[Press] to tare/zero the weight.

Toggle Units
[Press and hold] for five seconds to toggle units.

Switch Modes
[Press and hold] for one second to switch modes.

  • Please see the “Mode Introduction” section for more details.

Using the Acaia Brew guide

Using Brewguide for the First Time
Brewguide is a step-by-step interactive guide to brewing coffee. Simply scan the Acaia Brewguide QR code on the coffee bean bag, and use the Acaia Brewguide app to download the recipe to your Pearl S. In the Brewguide app, you can  also discover guides created by roasters around the world.

acaia PS001 Pearl Model S Coffee Scale - Brewguide

Download
Download the Brewguide app| Connect
Activate the Bluetooth on your phone and connect with the Pearl S| Start personalization
Follow the instructions on the Brewguide app

Using Brewguide on Pearl S

acaia PS001 Pearl Model S Coffee Scale - Using 1

Search or scan the QR
Code to find the brewguide
you need.| Select a brewguide.| Choose “Upload to Pearl
S” in the app to send it to
Pearl S.
acaia PS001 Pearl Model S Coffee Scale - Using 2|
Wait until the brewguide is sent to the Pearl S; this may take up to one minute.| Follow the guide and get brewing!|

Brew guide Action Buttons

Enter Brewguide mode
In any scale mode, [press and hold] for one second

Go to the next brewing step
In Brewguide mode, [press and hold] for one second

Replay the current brewing step
In Brew guide mode, [press] to replay

Go back to the previous brewing step
In Brewguide mode, [press and hold] for one second

Tare
In Brew guide mode, [press] to tare

Product Care Information

Battery Charge

  • You can charge the battery by plugging the USB cable into any of the power supplies listed below:
  • A computer
  • A USB wall-charger with an output of 5 volts and 1 amp
  • A DC car-charger with an output of 5 volts and 1 amp
  • It takes about 3-4 hours to fully charge the battery from empty. Try not to let the battery completely run out before charging. Charge the battery as needed.
  • A fully charged battery can provide up to 16 hours of working time in normal brightness and up to 40 hours in low brightness mode.
  • To check remaining battery level, see “Battery Level Indicator” section.
  • Note: Using a “fast-charging” charging block or charging hub (a charging block/hub delivering over 5v at 1A) could damage your Acaia scale’s circuit board.

Battery Indicator

acaia PS001 Pearl Model S Coffee Scale - Indicator

  • When the scale is off, the remaining battery level can be viewed by pressing and holding the power button until the battery level indicator is displayed.
  • You can also check the battery level by connecting the scale to Acaia Apps.

Calibration

acaia PS001 Pearl Model S Coffee Scale - Calibration

Turn on scale
Turn on the Acaia scale.| Tap Tare button
Make sure the scale is in  weighing mode and the unit is set to ‘gram’, then tap the ‘T’ button rapidly.| See CAL display
Keep tapping the ‘T’ button  until ‘CAL’ is shown on the display.| Place a weight
Place a weight (100 g/500 g/1000 g) on the scale and wait until the display shows ‘End’. Calibration is now complete!

Mode Introduction

Mode 1 – Weighing Mode
In the Weighing Mode, the scale will only display weight, in either grams or ounces.

  • There are two different weighing units in Weighing Mode: gram and ounce. A green dot will appear in the upper right of the LED display and the scale will read 0.000 when weighing in ounces.
  • The LED display shows [ 0.0 ] when the scale is measuring in grams.
  • The LED display shows [ 0.000 ] when the scale is measuring in ounces.
  • The readability is 0.1 g for grams and 0.005 oz for ounces.
Action Operation
Tare Weight Tap Tare button
Toggle Units g/oz Press and hold Tare button for five seconds
Reset Mode Double tap Tare button
Switch Mode Long press Power button

Mode 2 – Dual Display Mode
In the Dual Display Mode, the scale displays [ 0:00 0.0 ] with a timer (left) and weight (right).

  • There are two different weighing units in Dual Display Mode: gram and ounce.
  • The LED display shows [0:00 0.0] when the scale is measuring in grams.
  • The LED display shows [0:00 0.000] when the scale is measuring in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].
Action Operation
Start/Stop/Reset Timer Tap Power button
Tare Weight Tap Tare button
Reset Mode Double tap Tare button
Toggle Units g/oz Press and hold Tare button for five seconds
Switch Mode Press and hold Power button

Mode 3 – Pour Over Auto Start Mode
The Pour Over Auto Start Mode is designed to aid pour over coffee brewing. The scale will detect the start of the flow from kettle into the vessel and automatically start the timer function; the timer stops when the brewing equipment has  been removed from the scale. When the vessel is removed from the scale, the display flashes the final beverage weight.

Display

  • The LED display flashes [ 0.0 ] and [ 0:00 0.0 ] when measuring in grams and the timer is idle.
  • The LED display flashes [ 0.000 ] and [ 0:00 0.000 ] when measuring in ounces and the timer is idle.
  • Once the timer has started, the LED display shows [ 0:00 0.0 ], with the time elapsed on the left and the weight on the right in grams.
  • Once the timer has started, the LED display shows [ 0:00 0.000 ], with the time elapsed on the left and the weight on the right in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will display [ Maximum ].

Mode Description

  • If the timer has not started yet, the display will flash 0:00 and a water droplet.
  • The timer will start automatically when the first flow of water is detected.
  • The timer stops when the brewing equipment is removed. The scale will flash between the beverage weight and the tare weight of the items on the scale.
Action Operation
Start/Stop/Reset Timer Tap Power button
Tare Weight Tap Tare button
Reset Mode Double tap Tare button
Toggle Units g/oz Long press Tare button for five seconds
Switch Mode Press and hold Power button

Mode 4 – Portafilter Mode
The Portafilter Mode is designed to simplify the workflow of weighing coffee grounds in a portafilter. The scale automatically detects a portafilter or other vessel and tares the weight of the vessel. Remove the portafilter to add coffee  grounds, then place on the scale again to measure the weight of the coffee grounds. Repeat as needed to adjust the weight. After the portafilter has been removed for 15 seconds, the scale will reset the mode to default for the next workflow.

Display

  • When measuring in grams, the display shows [ 0.0 ] before a portafilter is placed on the scale.
  • When measuring in ounces, the display shows [ 0.000 ] before a portafilter is placed on the scale.
  • The display shows [ 0.0 ] after a portafilter has been registered.

Mode Description

  • Place an empty portafilter on the scale, and the scale will register the weight of the portafilter.
  • Remove the portafilter after [ ] disappears.
Action Operation
Tare Weight Tare function begins automatically when a stable weight is placed

on the scale
Reset Mode| Double tap Tare button
Toggle Units g/oz| Long press Tare button for five seconds
Switch Mode| Press and hold Power button

Note

  1. If the scale is left idle for 15 seconds or you double tap the Tare button, the Pearl Model S will automatically reset the mode to default for the next auto-tare operation.
  2. To change the timer reset length in Portafilter Mode, see the “Configuration” section.

Mode 5 – Espresso Mode
The Espresso Mode is designed to aid espresso extraction. The scale automatically detects a cup, shot glass, or other vessel and tares the weight of the vessel. The scale will then detect the start of the flow of espresso into the vessel and  automatically start the timer function; the timer stops when the flow of espresso into the vessel stops.
When the vessel is removed from the scale, the display flashes between the beverage weight and vessel weight.

Display

  • The LED display shows [ 0:00 0.0 ] with the timer on the left and the weight on the right in grams.
  • The LED display shows [ 0:00 0.000 ] with the timer on the left and the weight on the right in ounces.
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will  display [ Maximum ].

Mode Description

  • When an object (such as a cup) weighing two grams or more is placed on the scale and the weight reading is stable, the scale will perform auto tare.
  • After the scale detects the flow of espresso, the timer will start. The timer will stop when the espresso flow stops.
  • When the espresso is ready and the cup is removed, the display will flash between the beverage weight and the vessel weight.
Action Operation
Start/Stop/Reset Timer Tap Power button
Tare Weight Tap Tare button
Reset Mode Double tap Tare button
Toggle Units g/oz Long press Tare button for five seconds
Switch Mode Press and hold Power button

Note

  1. In Espresso Mode, the timer will stop when the espresso flow stops.
  2. The auto-tare function is performed only when the weight exceeds two grams.
  3. If you leave the scale idle for ten seconds, it will reset the timer and perform tare operation.
  4. In Espresso Mode, the timer will also stop when a negative weight (i.e., removal of a cup) is detected.

Mode 6 – Flowrate Mode
Designed for pour over coffee brewing. The display includes timer, flowrate, and weight.

  • The LED display shows [0:00 0.0 0.0] when the scale is measuring in grams.
  • The LED display shows [0:00 0.000 0.00] when the scale is measuring in ounces
  • When the weight exceeds 999 grams, the LED display only shows the integer part (the decimal point will not be displayed). The LED display shows up to a maximum of 3000 grams. If the weight exceeds 3000 grams, the scale will  display [ Maximum ].
  • The flowrate is measured in grams per second (g/s) on the right hand side of the display.
Action Operation
Start/Stop/Reset Timer Tap Power button
Tare Weight Tap Tare button
Reset Mode Double tap Tare button
Toggle Units g/oz Long press Tare button for five seconds
Switch Mode Long press Power button

Mode 7 – Flowrate Practice Mode
A real-time flowrate meter mode designed for practicing your infusion stability. The current flowrate is displayed on the left, and the stability of pouring is shown through the indicator bar.

  • The flowrate is measured in g/s and oz/s.
  • Each dot on the indicator bar represents a 0.5 g/s increment. The bar provides a visualization of flowrate stability.
Action Operation
Toggle Units g/oz Long press Tare button for five seconds
Switch Mode Long press Power button

Configuration

Enter Settings

  1. With the Pearl S powered off, press and hold the Power button. When the LED display shows [ ACAIA ] and then changes to [ SEt ], release the Power button.
  2. Tap the T button to enter Settings. The first setting is [ Brightness ].
  3. Please refer to the following table for key operations
Action Operation
Next Setting Tap Tare button
Previous Setting Tap Power button
Enter Setting Press and hold Tare button
Toggle Options Tap Tare button
Save Option Press and hold Tare button
Back to Menu without Saving Tap Power button
Exit Settings and Return to Modes Double tap Power button

Settings Menu

Setting Display Options Default
Brightness Setting Brightness Low. Medium. High. Bright Medium
Key Sound Setting Beep On. Off On
Default Weighing Unit Setting Unit Gram, Ounce Gram
Weighing Mode Setting Weighing Mode On. Off On
Dual Display Mode Setting Dual Display Mode On. Off On
Pour Over Auto Start Mode Setting Pour Over Auto Start Mode On. Off Off
Portafilter Mode Setting Portafilter Mode On. Off Of
Espresso Mode Setting Espresso Mode On. Off Of
Flowrate Mode Setting Flowrate Mode On. Off Off
Flowrate Practice Mode Setting Flowrate Practice Mode On. Off Of
Hello Message Setting Hello Message On. Off Off
Bluetooth Setting Bluetooth Setting On. Off On
Sleep Timer Setting Sleep Timer 5 Min, 10 Min, 20 Min. 30 Min. 60 Min, Off

5 Min
Battery Saving Setting| Battery Saving| 90 Sec. 180 Sec. Off| 90 Sec
Weighing Filter Setting| Filter| Normal. High. Sensitive| Normal
Zero Tracking Setting| Zero Tracking| 1 D. 2D, 3D. Off| 1D
Weighing Resolution Setting| Resolution| Default. Nigh. Low| Default
Timer Auto Stop on Cup Removal Setting| Timer Auto Stop on Cup Removal| 10 Sec. 30 Sec, 60 Sec. Off| 10 Sec
Portafilter Auto Reset Setting| Portafilter Auto Reset| 15 Sec. 30 Sec, 60 Sec| 15 Sec
Reset Default| Reset Default| No. Yes| No

Brightness Setting [Brightness]

  1. You can adjust the brightness of the LED display.
  2. Default brightness is set to Medium. Set to Bright when operating under strong light.

Key Sound Setting [Beep]

  1. Use this setting to turn the beeping sound on or off.

Default Weighing Unit Setting [Unit]

  1. The default weighing unit is set to be gram if [ Gram ] is selected and ounce if [ Ounce ] is selected.
  2. Tap the Tare button to switch the default weighing unit between gram and ounce.

Weighing Mode Setting [Weighing Mode]

  1. By default, the Weighing Mode is set to On.
    • On: The Weighing Mode is enabled.
    • Off: The Weighing Mode is disabled.

Dual Display Mode Setting [Dual Display Mode]

  1. By default, the Dual Display Mode is set to On.
    • On: The Dual Display Mode is enabled.
    • Off: The Dual Display Mode is disabled.

Pour Over Auto Start Mode Setting [Pour Over Auto Start Mode]

  1. By default, the Pour Over Auto Start Mode is set to Off.
    • On: The Pour Over Auto Start Mode is enabled.
    • Off: The Pour Over Auto Start Mode is disabled.

Portafilter Mode Setting [Portafilter Mode]

  1. By default, the Portafilter Mode is set to Off.
    • On: The Portafilter Mode is enabled.
    • Off: The Portafilter Mode is disabled.

Espresso Mode Setting [Espresso Mode]

  1. By default, the Espresso Mode is set to Off.
    • On: The Espresso Mode is enabled.
    • Off: The Espresso Mode is disabled.

Flowrate Mode Setting [Flowrate Mode]

  1. By default, the Flowrate Mode is set to Off.
    • On: The Flowrate Mode is enabled.
    • Off: The Flowrate Mode is disabled.

Flowrate Practice Mode Setting [Flowrate Practice Mode]

  1. By default, the Flowrate Practice Mode is set to Off.
    • On: The Flowrate Practice Mode is enabled.
    • Off: The Flowrate Practice Mode is disabled.

Hello Message Setting [Hello Message]

  1. By default, the Hello Message is set to Off.
    • On: The Hello Message will show when the scale is turned on.
    • Off: The Hello Message will not show when the scale is turned on.

Bluetooth Setting [Bluetooth Setting]

  1. By default, the Bluetooth is set to On.
    • On: The Bluetooth is enabled. The scale can be connected with Acaia apps.
    • Off: The Bluetooth is disabled. The scale does not allow any Bluetooth connection.

Sleep Timer Setting [Sleep Timer]

  1. The number displayed indicates the amount of time before the scale will automatically power off. For example, when 10 is selected and the scale is disconnected from all mobile devices, the scale will power off after 10 minutes of  idling.

Battery Saving Setting [Battery Saving]

  1. The default Power Saving Mode is set to 90 seconds.
  2. The Acaia Pearl Model S will wait for the selected number of seconds to enter Power Saving

Mode. The LED display will dim to save power.
Weighing Filter Setting [Filter]

  1. The weighing filter setting determines the speed with which the load receptor responds to and determines the weight. “High” indicates a more stable but slower weighing result; “Sensitive” indicates higher sensitivity and a faster  weighing result.

Zero Tracking Setting [Zero Tracking]

  1. Zero tracking is a function to help compensate the weight readout fluctuations at zero point to improve the usability of the scale. Acaia Pearl S is allowed to compensate the fluctuation by up to 2 d according to industrial weighing  guidelines.
  2. Off: It is not recommended to turn off zero tracking as the zero indication can drift easily with changing room temperatures.
  3. 0.5 d~3 d: For example, since each division is 0.1 g, 3 d = 0.3 g. When zero tracking is set to be 3 d, any initial weight between +/- 0.3 g on the weighing pan will be zeroed out.
  4. 1 d is recommended for Acaia Pearl Model S.

Weighing Resolution Setting [Resolution]

  1. The default weighing resolution is set to [ Default ], the division is 0.1 g for weights under 1500 grams and 0.5 g for weights between 1500 and 3000 grams.
  2. When the weighing resolution is set to [ High ], the division will be 0.1 g throughout the entire time from 0 to 3000 grams.
  3. When the weighing resolution is set to [ Low ], the division will be 1 g throughout the entire time from 0 to 3000 grams.

Timer Auto Stop on Cup Removal Setting [Timer Auto Stop on Cup Removal]

  1. After a cup is removed, the timer will automatically pause. This setting gives you options on how long to wait before pausing.
  2. The default value for this setting is ten seconds.

Portafilter Auto Reset [Portafilter Auto Reset]

  1. In Portafilter Mode, after a portafilter is removed, the weight will automatically reset. This setting gives you options on how long to wait before resetting.
  2. The default value for this setting is fifteen seconds.

Reset Default [Reset Default]

  1. To reset the scale to its factory default settings, go to [ Reset Default ], then choose [ Yes ]. The scale will clear the Hello Message and reset all settings including Brew guide data to factory default.

Appendix

acaia PS001 Pearl Model S Coffee Scale - Appendix

Buttons

| Function| Example
---|---|---
Power Button
| Turn on| Press and hold for 0.5 seconds to turn on the scale.
Turn off| Double-tap to turn off the scale.
Switch Mode| While the scale is turned on, press and hold for one second to switch modes.
Start/Stop/Reset Timer| Tap to start/stop/reset timer.
Back| While in Settings Menu, double tap to go back to Modes.
Tare Button
| Tare| Tap to perform tare operation.
Toggle units| Long press for five seconds to change weighing unit between gram and ounce.
Switch option| While in Settings, tap to advance through settings options. While in settings, tap to toggle options in sub menus.
Reset| Double tap to reset a mode. This zeroes the weight and sets the timer to 0:00.
Confirm| While in Settings, press and hold for two seconds to confirm the option selected in a sub menu.
Enter Brewguide Mode| Press and hold for one second to enter Brewguide Mode.
Enter Calibration Mode| While in Weighing Mode, rapidly tap to enter Calibration Mode.

LED Indicators

acaia PS001 Pearl Model S Coffee Scale - LED
Indicators

Battery charge/Charge error
The orange indicator on the upper left turns on when the battery is charging and turns off when the battery is fully charged. The indicator starts flashing or does not appear when the USB cable is not working.
Tare operation
The orange indicator on the lower left turns on when the Tare button is pressed.
Ounce indicator
The green indicator on the upper right turns on when the weight is measured in ounces.
Espresso Mode indicator
The green indicator on the lower right turns on when in Espresso Mode.

Error Codes

Error Code Description
Error 100 Access Code Error, unrecognized access code.
Error 101 EEPROM error, unable to access memory. Please contact Acaia

support.
Error 102| AD error, unable to access weighing signal. Please contact Acaia support.
Error 303| Unable to find acceptable starting Zero point, most likely because the loadcell
has been damaged by excessive force or drop. Please contact Acaia support.
Maximum| Overload: the weight is over the maximum capacity.
Underload| Underload: the weight is under the minimum capacity.
Error 304| Calibration error. Calibration cannot proceed when environmental noises are too strong. Please calibrate in a stable environment free of wind, vibration, etc.
Error 802| Unable to tare because the weight exceeds the acceptable tare range.
Error 803| Unable to tare because the weight is unstable.

Other

Display Code Description
UPDATE The scale is in update mode. During the update process, the green LED

on the lower right will blink until the process  is complete.
Note: If you want to leave update mode, please connect the scale’s USB to a power source.

Specifications

Model PS001 / PS002
Product Weight 52U g ± 5 g
Product Dimensions W: 160 mm L: 160 mm H: 32 mm
Maximum Capacity 3000 g / 105.82 oz
Minimum Weight 0.1 g
Measuring Units gram, ounce
Readability 0.1 g
Repeatability 0.1 g
Linearity 1 d (d = 0.1 g / 0.5 g)
Indication Limit 3090 g / 108.99 oz
Power Supply 5 V / 500 mA
Battery Lithium-ion rechargeable 3.7 V 2200 mAh
Battery Life Up to 16-40 hours
Display Dot matrix LED
Material PC
Connectivity Bluetooth 4.0
Inside the Package Acaia Pearl Model S Coffee Scale (White / Black) x 1 Heat

Resistant Coaster (Round) x 1
Micro USB Charging Cable x 1

Copyright
This user manual is protected by copyright. All rights reserved. No part of this manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written consent of Acaia.

© Acaia, California, 2022.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals