acaia AO203 Orion Mini Bean Doser User Manual

October 30, 2023
acaia

AO203 Orion Mini Bean Doser

Acaia Orion Mini Bean DoserTM User Manual

Model: AO203 / AO202

Version: 3.00.04

Introduction

The Acaia Orion Mini Bean DoserTM is a device designed for
dosing green or roasted coffee beans based on weight. It comes with
several features that make it an ideal device for coffee lovers who
want to have precise control over the coffee they use for
brewing.

Features

  • Fast Weight-Based On-Demand Dosing: The Orion Mini Bean DoserTM
    can dose 225 grams (1/2 lbs) in 12 seconds and 20 grams in 3
    seconds within the error margin of 2-3 beans.

  • Full Automatic Mode: Designed with a fully automatic mode for
    continuous dosing of multiple containers without pressing any
    buttons.

  • Intuitive Dial Interface: A new dial interface with three
    preset modes for storing different target weights and allowing easy
    access by rotating the dial for different functions.

  • Weighing Scale Mode: The Orion Mini Bean DoserTM can function
    as a smart industrial weighing scale with a capacity of up to 3000
    grams.

  • Statistic Tracking System: The Orion Mini Bean DoserTM can
    track statistical information such as total number of doses or
    total weight of the dosing session.

Interface Overview

The Orion Mini Bean DoserTM has the following interface
components:

  • Power Button
  • Modes LED Indicator
  • Dose Button
  • Presets
  • Rotate Dial
  • Ounce Indicator
  • Charging Indicator
  • Connect Indicator

Getting Started

Initial Setup

  1. Prior to using your Orion Mini for the first time you should
    rinse and clean the bean hopper in warm soapy water. Dry
    immediately after cleaning.

  2. Attach the bean hopper on top.

  3. Place a container on the weighing platform to avoid accidental
    dispensing.

  4. Connect the power cord to the Orion Mini.

  5. Place coffee beans into the hopper.

General Operation

The Orion Mini is designed for dosing portions of beans from 5
grams to a maximum of 3000 grams per dose with an accuracy of +/- 2
beans (~0.5 g). There are two dosing modes in the Orion Mini —
Manual mode and Auto mode. To choose between modes, press and hold
the Power button and the display will show the current mode of
operation. Rotate the dial to switch modes.

Product Care Information

Battery Charge

The Charging indicator will display when the battery is charging
and will turn off when the charger is removed. If the USB cable is
not working, the indicator does not appear. Please note that the
Orion Mini ONLY charges on the AC-DC adapter included in the
package. It does NOT charge with any other USB-C charger.

Acaia Orion Mini User Manual
AO203 / AO202

3.00.04

Contents

3 Introduction

3

Features

3

Interface Overview

4 Getting Started

4

Initial Setup

4

Getting Started

4

General Operation

5 Product Care Information

5

Battery Charge

5

Calibration

5

Care and Cleaning

6 Operations

6

Basic Operations

6

Set Preset Weight

6

Switch Mode

6

Empty Hopper

7 Mode Introduction

7

Mode 1 – Manual Dosing Mode

8

Mode 2 – Auto Dosing Mode

9

Mode 3 – Weighing Mode

10 Settings

10

Accessing the Orion’s Settings

10

Diagram of the Settings Menu

12 Appendix

12

Buttons

12

LED Indicators

13

Error Codes

13

Other

14 Specifications

Introduction
Features
The Orion Mini Bean DoserTM is designed for dosing green beans or roasted coffee beans based on weight.
Fast Weight-Based On-Demand Dosing The Orion Mini Bean DoserTM can dose 225 grams (1/2 lbs) in 12 seconds and 20 grams in 3 seconds within the error margin of 2-3 beans.
Full Automatic Mode Designed with a fully automatic mode for continuous dosing of multiple containers without pressing any buttons.
Intuitive Dial Interface A new dial interface with three preset modes for storing different target weights and allowing easy access by rotating the dial for different functions.
Weighing Scale Mode The Orion Mini Bean DoserTM can function as a smart industrial weighing scale with a capacity of up to 3000 grams.
Statistic Tracking System The Orion Mini Bean DoserTM can track statistical information such as total number of doses or total weight of the dosing session.
Interface Overview

Power Button Modes
LED Indicator Dose Button

Presets

Rotate

Ounce Indicator
Charging Indicator Connect Indicator

3

Getting Started
Initial Setup
1. Prior to using your Orion Mini for the first time you should rinse and clean the bean hopper in warm soapy water. Dry immediately after cleaning. 2. Attach the bean hopper on top. 3. Place a container on the weighing platform to avoid accidental dispensing. 4. Connect the power cord to the Orion Mini. 5. Place coffee beans into the hopper.
Getting Started
1. Make sure that the weighing platform is clean. 2. Turn on the Orion Mini by pressing Power and place the container on the platform. 3. Set target weight by pressing Power. Adjust values with Dial then short press Power to confirm. 4. Press Dose to start dosing. If the display shows [ CUP ] [ rESEt ], please place a container on the platform. 5. When a dose is complete, press Power to return to dosing.
General Operation
The Orion Mini is designed for dosing portions of beans from 5 grams to a maximum of 3000 grams per dose with an accuracy of +/- 2 beans (~0.5 g). There are two dosing modes in the Orion Mini — Manual mode and Auto mode. To choose between modes, press and hold the Power button and the display will show the current mode of operation. Rotate the dial to switch modes.
To take full advantage of the Orion Mini’s many features, carefully read through the entire manual, which contains step-by-step procedures, examples, and other information. Warning: Incorrect handling of this product could result in personal injury or physical damage.
4

Product Care Information
Battery Charge
The Charging indicator will display when the battery is charging and will turn off when the charger is removed. If the USB cable is not working, the indicator does not appear. Please note that the Orion Mini ONLY charges on the AC-DC adapter included in the package. It does NOT charge with any other USB-C charger.

Rotate

Charging Indicator

Calibration
1. While the Orion Mini is in Weighing Mode and the weighing unit is in grams, rapidly press the Dose button multiple times until the LED display shows [ CAL ] and then [ 500 ]. 2. Place a 500-gram calibration weight on the platform and wait for the Doser to execute the calibration procedure. 3. The display shows [ -End- ] when the calibration procedure is completed.

  • Note: Calibration weights of 100 g, 1000 g, 1500 g, 2000 g, and 3000 g can also be used. For highest accuracy use Acaia calibration weights or F1 or F2 Class calibration weights. Inexpensive lower-class calibration weights have a higher deviation from a true accurate weight.
    Care and Cleaning
    · Use a soft cloth with warm water only to clean the product. · Do not use detergent or other chemicals for cleaning and soaking as it can damage the anodized coating on the product.

5

Operations

Basic Operations

Action

Operation

Turn On Scale

Press Power

Turn Off Scale Toggle Presets

Double press Power Rotate Dial

Set Preset Weight

Press Power, rotate Dial, then press Power / Dose

Switch Mode

Press and hold Power, rotate Dial, then press Power / Dose

Start Dosing

Press Dose

Reset Mode

Press Power

Empty Hopper

Press and hold Dose

Stop Emptying Hopper Press Dose

In the main display menu, you may use the controls above to choose between presets, enter different dosing modes, or start dosing with the current mode.
Set Preset Weight

Action

Operation

Enter Preset Weight Setting

Press Power

Change Value

Rotate Dial

Save Preset Value

Press Power / Dose

There are 3 presets in the Orion Mini for storing desired weights. For example, you can set preset 1 at 18 g for dosing, preset 2 at 20 g, and preset 3 at 35 g. You may adjust the preset value with the controls above.

Switch Mode

Action

Operation

Enter Mode Setting

Press and hold Power

Switch Mode

Rotate Dial

Set Mode

Press Power / Dose

There are 2 different modes in the Orion Mini for operation — Manual dosing mode and Auto dosing mode. You may set different modes using the controls above.
Empty Hopper

Action

Operation

Empty Hopper

Press and hold Dose

Stop Emptying

Press Dose

Back to Preset

Press Power

To empty the bean hopper, you can press and hold the Dose button. The Orion Mini will continuously dispense the beans until you press the Dose button again to stop. Make sure you place a large container on the platform for this operation. There will be an `E’ indicator on the top left corner of the display when emptying the hopper.
6

Mode Introduction
Mode 1 – Manual Dosing Mode
This is the default mode for dosing.

Action Start Dosing Stop Dosing Pulse Beans Reset Mode

Operation Press Dose Press Dose Press Dose Press Power

1. Select a preset by rotating the Dial. Adjust the preset value by pressing Power and rotating the Dial. Press Power to confirm. 2. Press Dose, and the Orion Mini will begin dosing until desired weight is reached within +/- 0.5 g (solid green LED will display to indicate an accurate dose). 3. At the end of dosing, you may press Dose several times to `pulse’. Pulse will slowly add a few more beans if needed. 4. Press Power to start a new dose. · Manual dosing mode can dose on demand with a selected preset. · A [ NOISE ] message will show when a container is removed from the Orion Mini or when the platform is touched during dosing. Please dose again.
Pulse in Manual dosing mode The Orion Mini has a pulse function that adds a few beans to the dose manually at the end of each dose. To pulse (add) a few more beans at the end of each dose, simply press the Dose button and the Orion Mini will add a small amount of beans with each press. If one press doesn’t drop any beans, you can press it multiple times until the desired weight is reached.

7

Mode 2 – Auto Dosing Mode
Auto dosing mode can dose automatically whenever a container is placed on the platform. There will be an `A’ indicator on the top left corner of the display when in Auto mode.

At the end of auto dosing, you may press the Dose button to `pulse’ a few more coffee beans if required. A [ rEADY ] message will show on the display when auto dosing mode is in action. To leave the [ rEADY ] display, press the Power button. You will be able to return to the preset selection display.

Action Enter Ready State Start Dosing Stop Dosing Pulse Beans Reset Mode

Operation Press Dose Press Dose Press Dose Press Dose Press Power

Display rEADY

Description
Place container on the platform; dosing will start when weight is detected

1. Switch into automatic dosing mode by pressing and holding Power and selecting the Auto mode with the Dial. Press Power again to confirm the mode. 2. Select or adjust a preset weight. 3. Press Dose to start automatic dosing, the display will show [ rEADY ]. 4. To start the first dose, press Dose again and the automatic dosing will begin. 5. Remove the completed dose, and wait for the display to show [ rEADY ] again. 6. Place another container on top of the platform and dispensing will start again.
7. Press Power to set a different dose and leave the current auto dosing session.
· Auto dosing mode can dose automatically whenever a container is placed on the platform. · There will be an `A’ indicator on the top left corner of the display when in Auto mode. · A [ NOISE ] message will show when a container is removed from the Orion Mini or the platform is touched during dosing. Please dose again.
Pulse in Auto dosing mode The pulse function also works in the auto dosing mode. To pulse (or add) a few more beans at the end of each dose, simply press the Dose button and the Orion Mini will add a small amount of beans with each press. If one press does not dispense any beans, you can press it multiple times until the desired weight is reached.
8

Mode 3 – Weighing Mode
The weighing mode is the Orion Mini’s smart scale mode. It will function like an industrial weighing scale with a 3000-gram capacity. To switch to weighing mode, rotate the Dial until a `W’ indicator appears on the top left corner of the display.

Action Reset Mode/Zero Tare

Operation Press Power Press Dose

· The weight of the object on the platform will be shown on the display. · The Power and Dose buttons will function as Zero’ andTare’.

9

Settings

Accessing the Orion’s Settings
1. With Orion Mini powered on, press and hold Power to enter the Settings mode. The display will show [ SEt ]. 2. Press Dose to enter the Settings Menu. It will show the first setting for [ SPEEd ].

Action Enter Setting Mode Enter Setting Menu

Operation Press and hold Power Press Dose

Diagram of the Settings Menu

Setting

Display

Speed

SPEEd

Zero Tracking

trAcE

Key Sound

bEEP

Default Weighing Unit Unit

Cup Detection

CUP.d

Calibration

CAL

About

About

Options FASt, PrEC, grEEn 05, 1 d, 2 d, 3 d, 4 d, 5 d, Off On, Off g, oZ On, Off (Start calibration) (Show the current Orion Mini Firmware version)

Default PrEC 1 d On g On –

10

Dosing Speed [ SPEEd ] You may adjust the dosing speed to prioritize either the accuracy or the speed of dosing. There are three speed settings available:

  1. PrEC — Precision: Default speed, high accuracy. (default) 2. FASt — Fast: Faster speed, default accuracy (227 grams within 12 seconds); recommended for doses of 100 grams or more. 3. GrEEn — Green Bean: Default speed for green beans or light roast beans. To save your selection and exit the settings sub- menu, press Dose. [ SPEEd ] will display on the LED to confirm that the selected option has been saved.
    Zero Tracking Setting [ trAcE ] Zero Tracking is a function to help compensate the weight readout fluctuations at zero point to improve the usability of the scale. The Acaia Orion Mini is allowed to compensate fluctuations by up to 2d according to industrial weighing guidelines. 1. Off: It is not recommended to turn off Zero Tracking; the zero indication can drift easily as the room temperature changes. 2. 0.5 d~3 d: For example, since each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set to be 3 d, any initial weight between +/- 0.3 g on the weighing pan will be zeroed out. 3. 2 d is recommended in general for the Orion Mini. To save your selection and exit the settings sub- menu, press Dose. [ trAcE ] will display on the LED to confirm that the selected option has been saved.
    Key Sound Setting [ bEEP ] 1. Set the Key Sound function to Off/On to turn off/turn on the beeping sound. To save your selection and exit the settings sub-menu, press Dose. [ bEEP ] will display on the LED to confirm that the selected option has been saved.
    Default Weighing Unit [ Unit ] 1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected. 2. Rotate Dial to switch the Default Weighing Unit between grams and ounces. To save your selection and exit the settings sub-menu, press Dose. [ Unit ] will display on the LED to confirm that the selected option has been saved.
    Cup Detection [ CUP.d ] 1. The default setting is on. 2. On: Cup detection enabled. Orion will check if there is a container on the weighing platform. If no container is detected, Orion will not start dispensing the coffee beans. 3. Off: Cup detection disabled. Orion will start dispensing the coffee beans even if no container is detected.
    Calibration [ CAL ] Please go to Page 5: Calibration for more information.
    About [ About ] Shows the current Orion Mini Firmware version. To update to the latest version, please use Orion Mini Updater on www.acaia.co/pages/apps.
    11

Appendix

Buttons

Button Function

Turn On

Turn Off

Power Button

Set/Save Preset Weight Set Modes

Save the Setting and Return to Menu

Start Dosing

Dose Button

Empty Hopper Stop Emptying Hopper

Save the Setting and Return to Menu

Toggle Presets/Modes Rotate Dial
Adjust Preset Weights

Example Press to turn on the Orion Mini Double press to turn off the Orion Mini Press to set/save preset weight Press and hold to switch to Manual/Auto Mode
Press to save the Setting and go back to Menu
Press to start dosing when in Manual/Auto mode Press and hold for 5 seconds to empty the hopper Press to stop emptying the hopper
Press to save the Setting and go back to Menu
Rotate to toggle presets/modes Rotate to adjust the preset weights

  • Please go to Page 6: Operations for more details.
    LED Indicators

LED Indicator

Rotate

Green Light – Dosing progress indicator When the green light is blinking, dosing is in progress. Once dosing is complete, the indicator will display a solid green light.
Yellow Light – Dose warning indicator When the yellow light is lit, it means that the current dose is at least 0.5 grams less or more than the target amount. You may want to add some beans with the pulse function or remove some.
Red Light – System message indicator When the red light is displayed, there is a system error with the Orion Mini. Restart the Orion Mini. If the problem persists, please contact us at support@acaia.co.
12

Error Codes

Error Code Error 100 Error 101 Error 102 Error 303
Error 304 Error 802 Error 803 Error 904

Description Code error EEPROM error AD read error Unable to make zero point because the initial weight exceeds the limit (250% of capacity). Over load: The weight is over the maximum capacity. Under load: The weight is under the minimum capacity. Please calibrate the Doser in a stable environment free of vibration, wind, etc. Unable to tare because the weight exceeds the tare range. Unable to tare due to unstable weight. Password error (the default password is 0000).

Other

Display Code UPdAtE

Description
The Orion Mini is in Update mode. Note: If you want to exit update mode, the Orion Mini will automatically turn off and exit update mode after 1 minute and 30 seconds of no use.

13

Specifications

Model Number

AO203 / AO202

Dimensions

W: 303 mm L: 202 mm H: 352 mm

Weight

2850 g ± 10 g

Measuring Units

g, oz

Max Capacity

3000 g / 105.82 oz

Min Weight

0.1 g

Readability

0.1 g

Repeatability

0.1 g

Linearity

1 d / 2 d / 4 d

Indication Limit

3090 g / 108.99 oz

Input

12 Vdc, 2.0 A

Dosing Error Margin +/- 0.2 g

Battery

Li-Ion 18650 7.4 V 2600 mAh

Battery Life

Up to 48 hours

Display

LED

Connectivity

Bluetooth 4.0

Acaia Orion Mini Bean Doser × 1 Inside the Package Hopper with capacity for 350~400 g of beans × 1
Power Adapter × 1

14

Copyright
This User Manual is protected by copyright. All rights reserved. No part of the manual may be reproduced, processed, duplicated or published in any form by photocopying, microfilming, reprinting or any other method, in particular electronic means, without the written agreement of Acaia.
© Acaia, California, 2022.