acaia AO203 Orion Mini Bean Doser User Manual
- October 30, 2023
- acaia
Table of Contents
AO203 Orion Mini Bean Doser
Acaia Orion Mini Bean DoserTM User Manual
Model: AO203 / AO202
Version: 3.00.04
Introduction
The Acaia Orion Mini Bean DoserTM is a device designed for
dosing green or roasted coffee beans based on weight. It comes with
several features that make it an ideal device for coffee lovers who
want to have precise control over the coffee they use for
brewing.
Features
-
Fast Weight-Based On-Demand Dosing: The Orion Mini Bean DoserTM
can dose 225 grams (1/2 lbs) in 12 seconds and 20 grams in 3
seconds within the error margin of 2-3 beans. -
Full Automatic Mode: Designed with a fully automatic mode for
continuous dosing of multiple containers without pressing any
buttons. -
Intuitive Dial Interface: A new dial interface with three
preset modes for storing different target weights and allowing easy
access by rotating the dial for different functions. -
Weighing Scale Mode: The Orion Mini Bean DoserTM can function
as a smart industrial weighing scale with a capacity of up to 3000
grams. -
Statistic Tracking System: The Orion Mini Bean DoserTM can
track statistical information such as total number of doses or
total weight of the dosing session.
Interface Overview
The Orion Mini Bean DoserTM has the following interface
components:
- Power Button
- Modes LED Indicator
- Dose Button
- Presets
- Rotate Dial
- Ounce Indicator
- Charging Indicator
- Connect Indicator
Getting Started
Initial Setup
-
Prior to using your Orion Mini for the first time you should
rinse and clean the bean hopper in warm soapy water. Dry
immediately after cleaning. -
Attach the bean hopper on top.
-
Place a container on the weighing platform to avoid accidental
dispensing. -
Connect the power cord to the Orion Mini.
-
Place coffee beans into the hopper.
General Operation
The Orion Mini is designed for dosing portions of beans from 5
grams to a maximum of 3000 grams per dose with an accuracy of +/- 2
beans (~0.5 g). There are two dosing modes in the Orion Mini —
Manual mode and Auto mode. To choose between modes, press and hold
the Power button and the display will show the current mode of
operation. Rotate the dial to switch modes.
Product Care Information
Battery Charge
The Charging indicator will display when the battery is charging
and will turn off when the charger is removed. If the USB cable is
not working, the indicator does not appear. Please note that the
Orion Mini ONLY charges on the AC-DC adapter included in the
package. It does NOT charge with any other USB-C charger.
Acaia Orion Mini User Manual
AO203 / AO202
3.00.04
Contents
3 Introduction
3
Features
3
Interface Overview
4 Getting Started
4
Initial Setup
4
Getting Started
4
General Operation
5 Product Care Information
5
Battery Charge
5
Calibration
5
Care and Cleaning
6 Operations
6
Basic Operations
6
Set Preset Weight
6
Switch Mode
6
Empty Hopper
7 Mode Introduction
7
Mode 1 – Manual Dosing Mode
8
Mode 2 – Auto Dosing Mode
9
Mode 3 – Weighing Mode
10 Settings
10
Accessing the Orion’s Settings
10
Diagram of the Settings Menu
12 Appendix
12
Buttons
12
LED Indicators
13
Error Codes
13
Other
14 Specifications
Introduction
Features
The Orion Mini Bean DoserTM is designed for dosing green beans or roasted
coffee beans based on weight.
Fast Weight-Based On-Demand Dosing The Orion Mini Bean DoserTM can dose 225
grams (1/2 lbs) in 12 seconds and 20 grams in 3 seconds within the error
margin of 2-3 beans.
Full Automatic Mode Designed with a fully automatic mode for continuous dosing
of multiple containers without pressing any buttons.
Intuitive Dial Interface A new dial interface with three preset modes for
storing different target weights and allowing easy access by rotating the dial
for different functions.
Weighing Scale Mode The Orion Mini Bean DoserTM can function as a smart
industrial weighing scale with a capacity of up to 3000 grams.
Statistic Tracking System The Orion Mini Bean DoserTM can track statistical
information such as total number of doses or total weight of the dosing
session.
Interface Overview
Power Button Modes
LED Indicator Dose Button
Presets
Rotate
Ounce Indicator
Charging Indicator Connect Indicator
3
Getting Started
Initial Setup
1. Prior to using your Orion Mini for the first time you should rinse and
clean the bean hopper in warm soapy water. Dry immediately after cleaning. 2.
Attach the bean hopper on top. 3. Place a container on the weighing platform
to avoid accidental dispensing. 4. Connect the power cord to the Orion Mini.
5. Place coffee beans into the hopper.
Getting Started
1. Make sure that the weighing platform is clean. 2. Turn on the Orion Mini
by pressing Power and place the container on the platform. 3. Set target
weight by pressing Power. Adjust values with Dial then short press Power to
confirm. 4. Press Dose to start dosing. If the display shows [ CUP ] [ rESEt
], please place a container on the platform. 5. When a dose is complete, press
Power to return to dosing.
General Operation
The Orion Mini is designed for dosing portions of beans from 5 grams to a
maximum of 3000 grams per dose with an accuracy of +/- 2 beans (~0.5 g). There
are two dosing modes in the Orion Mini — Manual mode and Auto mode. To choose
between modes, press and hold the Power button and the display will show the
current mode of operation. Rotate the dial to switch modes.
To take full advantage of the Orion Mini’s many features, carefully read
through the entire manual, which contains step-by-step procedures, examples,
and other information. Warning: Incorrect handling of this product could
result in personal injury or physical damage.
4
Product Care Information
Battery Charge
The Charging indicator will display when the battery is charging and will turn
off when the charger is removed. If the USB cable is not working, the
indicator does not appear. Please note that the Orion Mini ONLY charges on the
AC-DC adapter included in the package. It does NOT charge with any other USB-C
charger.
Rotate
Charging Indicator
Calibration
1. While the Orion Mini is in Weighing Mode and the weighing unit is in
grams, rapidly press the Dose button multiple times until the LED display
shows [ CAL ] and then [ 500 ]. 2. Place a 500-gram calibration weight on the
platform and wait for the Doser to execute the calibration procedure. 3. The
display shows [ -End- ] when the calibration procedure is completed.
- Note: Calibration weights of 100 g, 1000 g, 1500 g, 2000 g, and 3000 g can also be used. For highest accuracy use Acaia calibration weights or F1 or F2 Class calibration weights. Inexpensive lower-class calibration weights have a higher deviation from a true accurate weight.
Care and Cleaning
· Use a soft cloth with warm water only to clean the product. · Do not use detergent or other chemicals for cleaning and soaking as it can damage the anodized coating on the product.
5
Operations
Basic Operations
Action
Operation
Turn On Scale
Press Power
Turn Off Scale Toggle Presets
Double press Power Rotate Dial
Set Preset Weight
Press Power, rotate Dial, then press Power / Dose
Switch Mode
Press and hold Power, rotate Dial, then press Power / Dose
Start Dosing
Press Dose
Reset Mode
Press Power
Empty Hopper
Press and hold Dose
Stop Emptying Hopper Press Dose
In the main display menu, you may use the controls above to choose between
presets, enter different dosing modes, or start dosing with the current mode.
Set Preset Weight
Action
Operation
Enter Preset Weight Setting
Press Power
Change Value
Rotate Dial
Save Preset Value
Press Power / Dose
There are 3 presets in the Orion Mini for storing desired weights. For example, you can set preset 1 at 18 g for dosing, preset 2 at 20 g, and preset 3 at 35 g. You may adjust the preset value with the controls above.
Switch Mode
Action
Operation
Enter Mode Setting
Press and hold Power
Switch Mode
Rotate Dial
Set Mode
Press Power / Dose
There are 2 different modes in the Orion Mini for operation — Manual dosing
mode and Auto dosing mode. You may set different modes using the controls
above.
Empty Hopper
Action
Operation
Empty Hopper
Press and hold Dose
Stop Emptying
Press Dose
Back to Preset
Press Power
To empty the bean hopper, you can press and hold the Dose button. The Orion
Mini will continuously dispense the beans until you press the Dose button
again to stop. Make sure you place a large container on the platform for this
operation. There will be an `E’ indicator on the top left corner of the
display when emptying the hopper.
6
Mode Introduction
Mode 1 – Manual Dosing Mode
This is the default mode for dosing.
Action Start Dosing Stop Dosing Pulse Beans Reset Mode
Operation Press Dose Press Dose Press Dose Press Power
1. Select a preset by rotating the Dial. Adjust the preset value by pressing
Power and rotating the Dial. Press Power to confirm. 2. Press Dose, and the
Orion Mini will begin dosing until desired weight is reached within +/- 0.5 g
(solid green LED will display to indicate an accurate dose). 3. At the end of
dosing, you may press Dose several times to `pulse’. Pulse will slowly add a
few more beans if needed. 4. Press Power to start a new dose. · Manual dosing
mode can dose on demand with a selected preset. · A [ NOISE ] message will
show when a container is removed from the Orion Mini or when the platform is
touched during dosing. Please dose again.
Pulse in Manual dosing mode The Orion Mini has a pulse function that adds a
few beans to the dose manually at the end of each dose. To pulse (add) a few
more beans at the end of each dose, simply press the Dose button and the Orion
Mini will add a small amount of beans with each press. If one press doesn’t
drop any beans, you can press it multiple times until the desired weight is
reached.
7
Mode 2 – Auto Dosing Mode
Auto dosing mode can dose automatically whenever a container is placed on the
platform. There will be an `A’ indicator on the top left corner of the display
when in Auto mode.
At the end of auto dosing, you may press the Dose button to `pulse’ a few more coffee beans if required. A [ rEADY ] message will show on the display when auto dosing mode is in action. To leave the [ rEADY ] display, press the Power button. You will be able to return to the preset selection display.
Action Enter Ready State Start Dosing Stop Dosing Pulse Beans Reset Mode
Operation Press Dose Press Dose Press Dose Press Dose Press Power
Display rEADY
Description
Place container on the platform; dosing will start when weight is detected
1. Switch into automatic dosing mode by pressing and holding Power and
selecting the Auto mode with the Dial. Press Power again to confirm the mode.
2. Select or adjust a preset weight. 3. Press Dose to start automatic dosing,
the display will show [ rEADY ]. 4. To start the first dose, press Dose again
and the automatic dosing will begin. 5. Remove the completed dose, and wait
for the display to show [ rEADY ] again. 6. Place another container on top of
the platform and dispensing will start again.
7. Press Power to set a different dose and leave the current auto dosing
session.
· Auto dosing mode can dose automatically whenever a container is placed on
the platform. · There will be an `A’ indicator on the top left corner of the
display when in Auto mode. · A [ NOISE ] message will show when a container is
removed from the Orion Mini or the platform is touched during dosing. Please
dose again.
Pulse in Auto dosing mode The pulse function also works in the auto dosing
mode. To pulse (or add) a few more beans at the end of each dose, simply press
the Dose button and the Orion Mini will add a small amount of beans with each
press. If one press does not dispense any beans, you can press it multiple
times until the desired weight is reached.
8
Mode 3 – Weighing Mode
The weighing mode is the Orion Mini’s smart scale mode. It will function like
an industrial weighing scale with a 3000-gram capacity. To switch to weighing
mode, rotate the Dial until a `W’ indicator appears on the top left corner of
the display.
Action Reset Mode/Zero Tare
Operation Press Power Press Dose
· The weight of the object on the platform will be shown on the display. · The
Power and Dose buttons will function as Zero’ and
Tare’.
9
Settings
Accessing the Orion’s Settings
1. With Orion Mini powered on, press and hold Power to enter the Settings
mode. The display will show [ SEt ]. 2. Press Dose to enter the Settings Menu.
It will show the first setting for [ SPEEd ].
Action Enter Setting Mode Enter Setting Menu
Operation Press and hold Power Press Dose
Diagram of the Settings Menu
Setting
Display
Speed
SPEEd
Zero Tracking
trAcE
Key Sound
bEEP
Default Weighing Unit Unit
Cup Detection
CUP.d
Calibration
CAL
About
About
Options FASt, PrEC, grEEn 05, 1 d, 2 d, 3 d, 4 d, 5 d, Off On, Off g, oZ On, Off (Start calibration) (Show the current Orion Mini Firmware version)
Default PrEC 1 d On g On –
–
10
Dosing Speed [ SPEEd ] You may adjust the dosing speed to prioritize either the accuracy or the speed of dosing. There are three speed settings available:
- PrEC — Precision: Default speed, high accuracy. (default) 2. FASt — Fast:
Faster speed, default accuracy (227 grams within 12 seconds); recommended for
doses of 100 grams or more. 3. GrEEn — Green Bean: Default speed for green
beans or light roast beans. To save your selection and exit the settings sub-
menu, press Dose. [ SPEEd ] will display on the LED to confirm that the
selected option has been saved.
Zero Tracking Setting [ trAcE ] Zero Tracking is a function to help compensate the weight readout fluctuations at zero point to improve the usability of the scale. The Acaia Orion Mini is allowed to compensate fluctuations by up to 2d according to industrial weighing guidelines. 1. Off: It is not recommended to turn off Zero Tracking; the zero indication can drift easily as the room temperature changes. 2. 0.5 d~3 d: For example, since each division is 0.1 g, 3 d = 0.3 g. When Zero Tracking is set to be 3 d, any initial weight between +/- 0.3 g on the weighing pan will be zeroed out. 3. 2 d is recommended in general for the Orion Mini. To save your selection and exit the settings sub- menu, press Dose. [ trAcE ] will display on the LED to confirm that the selected option has been saved.
Key Sound Setting [ bEEP ] 1. Set the Key Sound function to Off/On to turn off/turn on the beeping sound. To save your selection and exit the settings sub-menu, press Dose. [ bEEP ] will display on the LED to confirm that the selected option has been saved.
Default Weighing Unit [ Unit ] 1. The Default Weighing Unit is set to grams if [ 9 ] is selected and ounce if [ o2 ] is selected. 2. Rotate Dial to switch the Default Weighing Unit between grams and ounces. To save your selection and exit the settings sub-menu, press Dose. [ Unit ] will display on the LED to confirm that the selected option has been saved.
Cup Detection [ CUP.d ] 1. The default setting is on. 2. On: Cup detection enabled. Orion will check if there is a container on the weighing platform. If no container is detected, Orion will not start dispensing the coffee beans. 3. Off: Cup detection disabled. Orion will start dispensing the coffee beans even if no container is detected.
Calibration [ CAL ] Please go to Page 5: Calibration for more information.
About [ About ] Shows the current Orion Mini Firmware version. To update to the latest version, please use Orion Mini Updater on www.acaia.co/pages/apps.
11
Appendix
Buttons
Button Function
Turn On
Turn Off
Power Button
Set/Save Preset Weight Set Modes
Save the Setting and Return to Menu
Start Dosing
Dose Button
Empty Hopper Stop Emptying Hopper
Save the Setting and Return to Menu
Toggle Presets/Modes Rotate Dial
Adjust Preset Weights
Example Press to turn on the Orion Mini Double press to turn off the Orion
Mini Press to set/save preset weight Press and hold to switch to Manual/Auto
Mode
Press to save the Setting and go back to Menu
Press to start dosing when in Manual/Auto mode Press and hold for 5 seconds to
empty the hopper Press to stop emptying the hopper
Press to save the Setting and go back to Menu
Rotate to toggle presets/modes Rotate to adjust the preset weights
- Please go to Page 6: Operations for more details.
LED Indicators
LED Indicator
Rotate
Green Light – Dosing progress indicator When the green light is blinking,
dosing is in progress. Once dosing is complete, the indicator will display a
solid green light.
Yellow Light – Dose warning indicator When the yellow light is lit, it means
that the current dose is at least 0.5 grams less or more than the target
amount. You may want to add some beans with the pulse function or remove some.
Red Light – System message indicator When the red light is displayed, there is
a system error with the Orion Mini. Restart the Orion Mini. If the problem
persists, please contact us at support@acaia.co.
12
Error Codes
Error Code Error 100 Error 101 Error 102 Error 303
Error 304 Error 802 Error 803 Error 904
Description Code error EEPROM error AD read error Unable to make zero point because the initial weight exceeds the limit (250% of capacity). Over load: The weight is over the maximum capacity. Under load: The weight is under the minimum capacity. Please calibrate the Doser in a stable environment free of vibration, wind, etc. Unable to tare because the weight exceeds the tare range. Unable to tare due to unstable weight. Password error (the default password is 0000).
Other
Display Code UPdAtE
Description
The Orion Mini is in Update mode. Note: If you want to exit update mode, the
Orion Mini will automatically turn off and exit update mode after 1 minute and
30 seconds of no use.
13
Specifications
Model Number
AO203 / AO202
Dimensions
W: 303 mm L: 202 mm H: 352 mm
Weight
2850 g ± 10 g
Measuring Units
g, oz
Max Capacity
3000 g / 105.82 oz
Min Weight
0.1 g
Readability
0.1 g
Repeatability
0.1 g
Linearity
1 d / 2 d / 4 d
Indication Limit
3090 g / 108.99 oz
Input
12 Vdc, 2.0 A
Dosing Error Margin +/- 0.2 g
Battery
Li-Ion 18650 7.4 V 2600 mAh
Battery Life
Up to 48 hours
Display
LED
Connectivity
Bluetooth 4.0
Acaia Orion Mini Bean Doser × 1 Inside the Package Hopper with capacity for
350~400 g of beans × 1
Power Adapter × 1
14
Copyright
This User Manual is protected by copyright. All rights reserved. No part of
the manual may be reproduced, processed, duplicated or published in any form
by photocopying, microfilming, reprinting or any other method, in particular
electronic means, without the written agreement of Acaia.
© Acaia, California, 2022.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>