Product Information: Two Handle Lavatory Centerset Faucets

This product is a two handle lavatory centerset faucet. It comes with a 1.2GPM (4.5L/min) flow rate, making it compliant with California water efficiency regulations. The faucet also complies with California Proposition 65 and the Federal Safe Drinking Water Act.

The faucet has a durable finish that can be damaged by harsh abrasives or polish. To clean the faucet, simply wipe it gently  with a damp cloth and blot dry with a soft towel.

In areas with extremely low water pressure, causing unsatisfactory water flow in the basin faucet, you can replace the 2.2 GPM aerator to improve the water flow.

Product Usage Instructions

Maintenance
If the faucet exhibits very low flow:

  1. Remove and clean the aerator with your hand.
  2. Shut off the water supply valves.
  3. Replace the valve assembly.
  4. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench.

If the faucet leaks from under the handle:

  1. Using a wrench, ensure the bonnet nut is tight.
  2. If the leak persists, shut off the water supply valves.
  3. Replace the valve assembly.
  4. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench.

If the faucet leaks from the spout outlet:

  1. Shut off the water supply valves.
  2. Replace the valve assembly.
  3. When reinstalling parts, make sure the bonnet nut is tightened securely with a wrench.
  4. Install the valve assembly correctly for proper handle rotation.

Installation
Before installing the valves, clean the water pipe thoroughly to avoid dirt and deposits. Use silicone under the base if the deck is uneven.

  1. Attach the mounting nut to the hot and cold threaded mounting shanks and tighten the faucet to the basin.
  2. Attach the supply lines. Do not overtighten.
  3. Turn the water back on.

To flush debris from the plumbing system:

  1. Remove the aerator by hand.
  2. Run hot and cold water for one minute.
  3. Replace the aerator.

Repeat the above steps for the other hose connection, making sure to connect the hose with the hot label to the hot supply valve and the other hose to the cold supply valve. Flush the system and check for leaks by turning on the hot and cold water supplies and flushing the water lines for one minute. Check all connections for leaks and retighten if necessary, but do not overtighten.

WOWOW-2323000-BHHD-4-Inch-Centerset-Double-Handle-Mid-Arc-Bathroom-
Faucet-01 WOWOW-2323000-BHHD-4-Inch-Centerset-Double-
Handle-Mid-Arc-Bathroom-Fauce-03 WOWOW-2323000-BHHD-4-Inch-Centerset-Double-
Handle-Mid-Arc-Bathroom-Faucet-02 WOWOW-2323000-BHHD-4-Inch-Centerset-Double-
Handle-Mid-Arc-Bathroom-Faucet-04

Notes Before installing the valves, clean the water pipe thoroughly to avoid dirt and deposits.

  1. Provided with necessary models.
    OPTION: Use silicone under the base if deck is uneven.

  2. Attach the mounting nut to the hot and cold threaded mounting shanks and tighten faucet to basin. WOWOW-2323000-BHHD-4-Inch-Centerset-Double-Handle-Mid-Arc-Bathroom-Faucet-08

  3. Attach supply lines . Do not overtighten. Turn water back on.

    1. Remove the washer (2) , black gasket (4) and nut (5) from the assembly.
  4.  Slide washer (2) up to underside of flange (3).
    Insert flange (3) and washer (2) into sink and secure with the black gasket (4) washer and nut (5) from underneath the sink.

  5. Put down and check the Spring loaded stopper (1). 4. Connect assembly to drain.

  6. WOWOW-2323000-BHHD-4-Inch-Centerset-Double-Handle-Mid-Arc-Bathroom-Faucet-10 To flush debris from the plumbing system:

  7.  Remove the aerator by hand.

  8. Run hot and cold water for one minute.

  9. Replace the aerator.

WOWOW-2323000-BHHD-4-Inch-Centerset-Double-Handle-Mid-Arc-Bathroom-
Faucet-12

Repeat for other hose connection making sure the hose with the hot label is connected to the hot supply valve and the other hose is connected to the cold supply valve.

FLUSH SYSTEM/CHECK FOR LEAKS.
Turn on hot and cold water supplies and flush water lines for one minute. Check all connections at arrows for leaks.
Retighten if necessary, but do not overtighten.