geemarc PSA 100 Wireless Pressure Mat Doorbell And Alarm System Instruction Manual

June 13, 2024
geemarc

geemarc-logo

geemarc PSA 100 Wireless Pressure Mat Doorbell And Alarm System

geemarc-PSA-100-Wireless-Pressure-Mat-Doorbell-And-Alarm-System-
product

Product Information

The Amplicall PSA 100 is a wireless pressure mat doorbell and alarm system. It consists of a pressure sensor pad, an alert receiver, and optional power adapter. The pressure sensor pad is battery-operated and can detect the presence of a person or a sufficiently large weight. It is equipped with a CR2032 button battery (not included) and has a red light indicator. The alert receiver is powered by 3 LR14 alkaline batteries (not included) or a 6V 0.3A power adapter (sold separately). It has a ringing level adjustment, indicator lights for alarm status, and a low battery indicator light. The product can be used in various settings such as doorsteps, hallways, multistorey buildings, or for childcare and elderly care purposes. For important updates and changes, please visit our website:  www.geemarc.com

Product Usage Instructions

Installation:

  1. Place the pressure sensor pad at the desired location.
  2. Open the sensor pad by removing the cover held by double-sided Velcro.
  3. Take out the transmitter from the pressure sensor pad.
  4. Using a flat screwdriver, remove the cover of the transmitter.
  5. Insert a CR2032 button battery into the transmitter, respecting the polarity.
  6. Close the battery cover and check that the red light illuminates by pressing the center of the pressure sensor pad.
  7. Put the transmitter back into the pressure sensor pad and close the Velcro part.
  8. Activate the alert receiver by removing the marker screw and opening the battery compartment cover.
  9. Insert 3 LR14 alkaline batteries into the battery compartment, respecting the polarity.
  10. Close the battery compartment lid.
  11. Place the receiver in a wall position by making two separate horizontal holes of 36mm.
  12. Insert two wall fixing pins into the holes.
  13. Screw two screws into the pins, allowing them to protrude 5mm.
  14. Slide the receiver into the marked positions, pressing down to lock it.
  15. Note: You can also connect a 6V 0.3A power adapter (sold separately) for continuous operation.

Using Your Device:
The Amplicall PSA 100 system is easy to use:

  • Place the pressure sensor pad at a desired location where you want to detect presence or weight.
  • When the pressure sensor pad detects a person or weight, the alert receiver will start ringing or beeping based on the chosen mode (low or high ringing level).
  • Immediately after detection, the three indicator lights on the receiver will flash.
  • The system can be used in various scenarios such as doorsteps, hallways, multi-storey buildings, or for childcare and elderly care purposes.

Wireless Pressure Mat Doorbell And Alarm System

!!! Please check our website: www.geemarc.com as there may be important updates and changes that you need to be aware of.!!!

Contents of the box

The box contains the following:

  • 1 user guide
  • 1 pressure sensor pad (CR2032 battery not included)
  • 1 alert receiver
  • batteries are not provided
  • power adapter is provided as an option (6v 0.3a)

DESCRIPTION of receiver and transmitter
description of the alert receiver

  1. Ringing level low (Lo)/strong (Hi) 2,3,4. Indicator lights of alarm

  2. Low battery indicator light

  3. Ringing of the bell

  4. Switch buzzer/stop/alert

  5. Power adapter connector 6V 0.3A
    geemarc-PSA-100-Wireless-Pressure-Mat-Doorbell-And-Alarm-System-
\(2\)

  6. “Learn” pairing touch

  7. Battery compartment cover

  8. Wall mounting of the receiver

description of the issuer

  1. Battery compartment cover (PP3 9V not included)
  2. Presence detection pad

INSTALLATION

Operation of the pressure sensor

  1. Go around the pressure detector (Fig.1) by sensing it, once you feel a thickness, on the edge of the detector, open the detector by the part that is held by double-sided Velcro.
  2. Take the transmitter out of the pressure detector
  3. Insert a flat screwdriver (Fig.2) where the hole is located and lever to remove the cover.
  4. Insert the CR2032 button battery respecting polarity. (Fig.3)
  5. Put the battery cover back in place and check that the red light illuminates in the centre of the transmitter by pressing the centre of the pressure sensor pad.
  6. Put the transmitter back into the pressure sensor and close the Velcro part.

geemarc-PSA-100-Wireless-Pressure-Mat-Doorbell-And-Alarm-System-
\(5\)

Activating your alert receiver

  1. Remove the marker screw (Fig. 4) with your cruciform and open the cover of the pile compartment (9) by sliding it down.

  2. Insert the 3 1.5 V LR14 alkaline batteries (not included) respecting the polarity “+” and “-” (Fig. 5)
    geemarc-PSA-100-Wireless-Pressure-Mat-Doorbell-And-Alarm-System-
\(6\)

  3. Close the lid of the battery compartment by sliding it up.

  4. Replace the reference screw (10) with your cruciform

  5. You can place your receiver in wall position, make 2 separate horizontal holes of 36 mm

  6. Insert 2 wall fixing pins into the 2 holes

  7. Screw 2 screws into the pins and let them protrude 5mm, then slide them into 11 marks by pressing down your receiver to lock it.

Note: you can connect a 6V 0.3A adapter which is sold as an option. You can leave the batteries in your
Device for operation in case of power failure.

The middle light (3) will start flashing to warn you that the battery will need to be replaced.

Using your device

The Amplicall PSA 100 system you just bought is very easy to use, it is composed of a sensor of Pressure with transmitter and wireless alert receiver.
Your system is intended to warn you, for example, that a person
or a sufficiently large weight is on the pressure detector.
At this point, your alarm receiver will start to ring or beep (in weak or strong position) depending on the mode chosen and it will have the 3 indicator lights that will flash immediately after detection.

Example: you can place your pressure sensor at the step of a door, in a hallway, multi-storey building, in care for children or elderly etc.

Please note:
Attention should be paid to the maximum distance of use Of 30 meters.

geemarc-PSA-100-Wireless-Pressure-Mat-Doorbell-And-Alarm-System-
\(7\)

  1. Place your cushion in the desired Place.
    Set the switch (6) on your receiver to the position:
    “CHIME” it will beep and blink only once for 5 seconds when it receives information from the transmitter.

  2. ALARM” it will ring and flash once for 30 seconds when a signal is received from your transmitter.

Note: place your switch on the OFF of your alarm receiver to stop it ringing.
If you are no longer using your PSA 100 Amplicall system, please remove the batteries in your receiver and transmitter to save them.

Recording a new receiver on your sensor pad
Note: when you receive your Amplicall PSA100 package, the devices are already paired. So you don’t need to follow the steps below.
P To pair a new receiver (10 maximum),

Please follow the steps below:

  • Step 1: turn on your receiver in “Alarm” mode or “Chime” and enter recording mode on your receiver by remaining press the button. (8) “LEARN” using a pen for 3 seconds, release the button when you hear a beep.
  • Step 2: immediately afterwards, put a weight or walk on the pressure sensing pad.
  • Step 3: if the recording is successful, your receiver will make 4 beeps and will start ringing according to the mode of your alarm

Clear a receiver from the cushion
Detector detector
You can delete the recording from a receiver by pressing its “LEARN” button (8) for 12 seconds, you will hear 2 long sound beeps to confirm the deletion.

Characteristic of your AMPLICALL PSA 100
Range: up to 30 meters
Frequency of use: 433.92Mhz

Level of ringtone:
Receiver: 85dB (strong) 70dB (low)

Energy in Europe:
Transmitter: 1 button cell CR2032 receiver:
3 batteries Alkaline 1.5V type LR14 Number of receive for a transmitter : 10

Breakdown Service
The receiver does not sound:

  1. Please check that the receiver is either on the function ALARM or either on CHIME
  2. Check that the transmitter has its red light sui lights up in the middle of the transmitter when you press the pressure sensor. If this is not the case, replace the CR2032 button battery.
  3. Check that the receiver is not more than 30 meters from The issuer
  4. Check that there is pressure on the sensor pad Pressure pressure

Note: change the 3 LR14 batteries when the indicator light (3) flashes your receiver makes a double beeps, it is to warn that the battery of your transmitter is to be replaced

FCC Warning

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

NOTE 1: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE 2: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
The device has been evaluated to meet general RF exposure requirement. The device can be used in portable exposure condition without restriction

Directive IC
“This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions:

  1. This device may not cause interference; and
  2. This device must accept any interference, including interference that may cause undesired operation of the device.”

Guarantee Guarantee

Your Geemarc AMPLICALL PSA 100 product is guaranteed for 2 years, depending on the date of purchase. During this period, all repairs or replacements (at our sole discretion) will be made at no charge. If you have any problems, please contact our helpdesk or visit our website: www.Geemarc.com. The warranty does not cover accidents, negligence or broken parts. The product must not be altered or disassembled by anyone who is not an approved representative Of Geemarc. The Geemarc warranty does not limit in any way Your legal rights.

IMPORTANT: YOYR INVOICE IS PART OF YOUR WARRANTY AND MUST BE KEPT AND PRODUCED DURING A WARRANTY CLAIM.

DÉCLARATION

Directives CE
Geemarc Telecom SA hereby declares that its AMPLICALL PSA 100 Complies with the essential requirements as well as other relevant directives of standard 2014/53/UE.
The declaration of conformity can be consulted on the following website www.geemarc.com

Guidelines for recycling Weee (waste electrical and electronic equipment)
Was created for end-of-life products to facilitate their recycling. When this product is at the end of its life, please do not dispose of it in your household garbage bin.
Please use one of the following disposal options: remove the batteries and put them in a suitable weee bin. Place the product in a suitable weee bin.
or, return the old product to the retailer. If you buy a new one, they should accept it. Thus, if you follow these instructions, you are ensuring the protection of human health and the environment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals