Danfoss BFP 52E Fuel Pump User Manual
- June 12, 2024
- Danfoss
Table of Contents
ENGINEERING
TOMORROW
Data sheet
Fuel Pump type BFP 52E- size 3 and 5
Compatible with heating oil up to 100% biodiesel (FAME and UCOME)
Application
BFP 52E fuel pumps – size 3 and 5 are designed for small/medium-sized 2-stage domestic fuel burners up to 42 l/h.
BFP 52E features:
- Light oil, kerosene and biofuel blends hereof
- 1 or 2-pipe operation
- 2-stage
- Two built-in pressure regulators
- Solenoid valve cut-off
- Cartridge filter
- Bio compatible pressure and solenoid valve (Bio100 – version)
Function
From the suction inlet (S) fuel is drawn through the filter (H) to the gear
set, where the pressure is increased. By means of the diaphragm (D) in the
pressure regulator for stage 1 (T1), the pressure is kept constant at the
value set on adjustment screw (P1).
When voltage is applied to the NC-valve, it opens and releases fuel to the
nozzle outlet.
When voltage is applied to the NO-valve, it closes and puts the pressure
regulator (T1) out of function.
The pressure now rises to the pressure regulator (T2) value for stage 2 set on
adjustment screw (P2).
In 2-pipe systems the excess fuel is led back to the return outlet (R) and the
tank. In 1-pipe systems with plugged return outlet (R) and screw (A) removed,
the fuel is returned internally to the gear set (see figure).
Cut-off function, solenoid valve
When the burner stops, the voltage to the solenoid valves is cut off.
The NO-valve opens and the NC-valve closes and cuts off the fuel flow to the
nozzle outlet immediately.
Bleeding
In 2-pipe systems the pump is self-priming, i.e.
bleeding is performed via the constriction (O) to the return outlet (R).
In 1-pipe systems with plugged return outlet (R), bleeding must be performed
through the nozzle outlet (E) or the pressure gauge port (P).
Warranty
For pumps used outside the stated technical data and used with fuel containing
abrasive particles Danfoss cannot give any warranty.
Note!
Do not mount the pump with the solenoid valve pointing downwards.
The solenoid valve must be replaced after 250.000 operations or 10 years
(approved life expectancy).
By changing the materials of the components within our pumps, in relation to
the different types of fuels
– we ensure all product components are 100% bio compatible.
Identification
Nozzle capacity at 4.3 cSt., 10 bar, 2800 min-1
Technical data
8FP 52E | 3 | 5 |
---|---|---|
Fuel type | Standard fuel according to DIN EN 51603-1 and biofuel according to |
DIN EN 51603-6;-8 and EN14214
Viscosity range (measured in suction inlet) 1| (1.3) 1.8 to 12.0 cSt. (mmVs)
Filter area/mesh| 11 cm2/200 pm
Pressure range, stage 1 1)2)| 7 to 15 bar
Pressure range, stage 2 1)2)| 10 to 25 bar
Default setting, stage 1| 10 ±1 bar
Default setting, stage 2| 13 ±1 bar
Max. pressure in suction inlet/return outlet| 2 bar
Speed| 2400 to 3450 mint-1| 1400 to 3450 mind-1
Max. starting torque| 0.1 Nm| 0.12 Nm
Ambient/transport temperature| -20 to +70° C
Temperature of medium| 0 to +70° C
Coil power consumption| 9 W
Rated voltage (other voltages on request)| 230 V, 50/60 Hz
Coil enclosure| IP 40
Shaft/neck| EN 225
1)Max. 12 bar at 1.3 cSt., max. 15 bar at 1.8 cSt.
2)If blend oil used, technical data can be different
Nozzle capacity
Operating torque
Power consumption
Connections
Example shows BFP 52E L5LP1: Pressure adjustment stage 1
P2: Pressure adjustment stage 2
S: Suction inlet G 1/4
R: Return outlet G 1/4
E: Nozzle outlet G 1/8
P: Pressure gauge port G 1/8
V: Vacuum gauge port G 1/8
H:Filter
Note! Shaft rotation, location of nozzle outlet and other connections are
seen from shaft end.
RH: R-rotation
LH: L-rotation
Change-over and Filter Replacement H: Filter
A: 2-pipe operation, with screw
1-pipe operation, without screw
Dimensions
Additional documentation on burner components is available on
http://danfoss.com/
Danfoss A/S
Climate Solutions • danfoss.com • +45 7488 2222
Any information, including, but not limited to information on selection of
product its application or use, product design, weight, dimensions, capacity
or any other technical data in product manuals, catalogues descriptions,
advertisements, etc. and whether made available in writing, orally,
electronically, online or via download, shall be considered informative, and
is only binding if and to the extent explicit reference is made in a quotation
or order confirmation. Danfoss cannot accept any responsibility for possible
errors in catalogues, brochures, videos and other material.
Danfoss reserves the right to alter its products without notice. This also
applies to products ordered but not delivered provided that such alterations
can be made without changes to form, fit or function of the product.
All trademarks in this material are property of Danfoss A/S or Danfoss group
companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All
rights reserved.
© Danfoss | DCS-SGDPT/DK | 2023.03
AI131186455414en-010401
Documents / Resources
|
Danfoss BFP 52E Fuel
Pump
[pdf] User Manual
BFP 52E Fuel Pump, BFP 52E, Fuel Pump
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>