Limoges Medium Tall Pendant

Item #: SK 5361

This Limoges Medium Tall Pendant is a light fixture that requires careful installation in accordance with all applicable, local installation codes. It should be installed by a person familiar with the construction and operation of the fixture, as well as the hazards involved. It is important to inspect the item and its contents carefully before installation. If any damage or defect is found, do not proceed with the installation. Retain all packaging material until the installation is complete and approved.

Tools Required (Not Included)

  • Phillips Screwdriver
  • Slotted Screwdriver
  • Slip Joint Pliers
  • Needle-nose Pliers
  • Wire Cutters
  • Wire Strippers
  • Chain Pliers
  • Measuring Tape

Product Usage Instructions

  1. Carefully remove all parts from the box and place them on a clean, soft surface.
  2. Determine the desired overall length and the amount of chain (G) needed.
  3. Wrap the fixture ground wire (bare copper) around the green grounding screw (refer to diagram 2) and tighten it. Then, continue the fixture ground wire and connect it to the supply ground wire (usually green or bare copper) using a wire nut (A). Note that it is imperative for the fixture to be grounded.
  4. Connect the fixture neutral wire (ribbed) to the supply neutral wire (usually white) using a wire nut (A).
  5. Connect the fixture hot wire (smooth with markings) to the supply hot wire (usually black) using a wire nut (A). Be cautious not to reverse the hot and neutral connections.
  6. Ensure that all wire connections are tight, and then carefully tuck them into the junction box.
  7. Install the canopy (E) to the collar loop (D) by securing it with the collar ring (F).
  8. Install the light bulb into the socket.

Care Instructions

Clean the Limoges Medium Tall Pendant only with a soft dry cloth or feather duster. Do not use abrasive or chemical agents.

ASSEMBLY INSTRUCTIONS

VISUAL-COMFORT-SK-5361-Limoges-Medium-Tall-
Pendant-fig-1

Limoges Medium Tall Pendant
Item # SK 5361

This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.

TOOLS REQUIRED

(NOT INCLUDED):

  • Phillips Screwdriver
  • Slotted Screwdriver
  • Chain Pliers
  • Slip Joint Pliers
  • Needle-nose pliers
  • Measuring Tape
  • Wire Cutters
  • Wire Strippers
  1. Carefully remove all parts from the box. Place on a clean, soft surface.
  2. Determine desired overall length, and amount of chain (G) needed. Shorten chain using needle-nose pliers (see diagram 1). (Keep extra chain)
  3. Remove mounting plate (B) from collar loop (D).
  4. Thread fixture wire and ground wire through chain (G), collar ring (F) and canopy (E).
    • NOTE: When you reach the collar loop (D), ensure there is no tension on the wires. Cut excess wires, being sure to leave about 12” to reach the junction box.
  5. Separate two sides of molded wire, and strip insulation on each 5/8″.
  6. Twist all fixture wires together. Slip through center hole of collar loop (D).
    • NOTE: Untwist wires and separate to prepare for connection.
  7. Attach mounting plate (B) to collar loop (D) and secure using pliers to tighten locknut.
  8. Install fixture by securing mounting plate (B) to the junction box using mounting screws (C).VISUAL-COMFORT-SK-5361-Limoges-Medium-Tall-Pendant-fig-2
    • NOTICE:
    • This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved.
  9. Wrap fixture ground wire (bare copper) around the green grounding screw (see diagram 2). Tighten. Continue fixture ground wire and connect to supply ground wire (usually green or bare copper) using wire nut (A).
    • NOTE: It is imperative that the fixture is grounded.
  10.  Connect fixture neutral wire (ribbed) to the supply neutral wire (usually white) using wire nut (A).
  11.  Connect fixture hot wire (smooth with markings) to the supply hot wire (usually black) using wire nut (A).
    • CAUTION: Do not reverse the hot and neutral connections.
  12. Make sure all wire connections are tight, then carefully tuck into the junction box.
  13.  Install canopy (E) to collar loop (D) by securing with collar ring (F).
  14. Install light bulb into the socket.