PHILIPS RC136V WIA EL CoreLine Recessed Installation Guide

June 12, 2024
Philips

Coreline Recessed
RC136V WIA EL

Safety cable

PHILIPS RC136V WIA EL CoreLine Recessed- Safety cablePHILIPS RC136V WIA EL CoreLine Recessed-
Icon

| Power| Lumen output (lm)| Efficacy (lm/(W)| CCT (K)| |
---|---|---|---|---|---|---
RC136B 40S/830 WIA W60L60 OC ELB3| 35 W| 4000| 114| 3000| 19| 4.0
RC136B 43S/840 WIA W60L60 OC ELB3| 4300| 123| 4000
RC136B 43S/840 WIA W60L60 OC W3 ELB3| 4300| 123| 4000
RC136B 40S/830 WIA W60L60 OC W3 ELB3| 4000| 114| 3000
| A(mm)| B(mm)| C(mm)| D(mm)
---|---|---|---|---
RC136B W60L60| 44| 597| 597| 12

PHILIPS RC136V WIA EL CoreLine Recessed- Icon 3

SP suspended|
---|---
 VPC visible profile ceiling|
SM surface mounted|
 PCV plaster ceiling|

PHILIPS RC136V WIA EL CoreLine Recessed- FigPHILIPS RC136V WIA EL CoreLine Recessed- Fig 1PHILIPS RC136V WIA EL CoreLine Recessed- Fig
2

Battery replacement

PHILIPS RC136V WIA EL CoreLine Recessed- Fig 3

Indicator LED

**** The indicator LED must be mounted into the ceiling, close to the luminaire

Battery Unit

Manufacturer| Philips
Unit| TrustSight 3.6V 3cell 4000mAh batt NiMH
Power| 3 W
Duration| 3 h
Number of cells| 3
Nominal voltage| 3.6 V
Luminous Flux| 350 Im

**** Do not lift and handle the luminaire with the cable between driver (cover) and TrustSight invertor.

W60L60 NOC
Rated light output in emergency operation mode:  350Im|  W30L120 NOC
Rated light output in emergency operation mode: 350Im|  W60L60 OC
Rated Light output in emergency operation mode: 350Im| W30L120 OC
Rated light output in emergency operation mode: 350Im
---|---|---|---
PHILIPS RC136V WIA EL CoreLine Recessed- Polar| | |

Charge timePHILIPS RC136V WIA EL CoreLine Recessed -
Charge

Lifetime
The batteries have a life time expectancy of 4 years when maintained properly. Replace after that time!
Automatic emergency time selection
After installation and power up the driver will detect the battery and start the automatic detection process.

  • During automatic detection, the indicator LED willlight up with short green flashes.
  • Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of cells) and will set the emergency output power accordingly.
    After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted, e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.

Periodic testing
Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7.2.3 and 7.2.4.
Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for a period sufficient to ensure that each lamp is illuminated. Twice per year, each luminaire shall be tested for its full rated duration (at least 3hrs).
For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.

LED indicator status

LED indicator (color / flashing)| Error condition| Cause| Solution
---|---|---|---
Green / no flashing| System OK battery fully charged
Off| Mains oft EM mode, Rest mode, test in progress
Green /slow (0.25s on, 1.25s ofo|  | System OK battery is charging
Green/ fast (0.25s on, 0.25s off)|  | System OK recently tested (< 5 days Australia mode only)
Red/no flashing| Battery voltage too high or too low| No battery connected| Connect battery
 |  | Wrong or bad battery connected| Replace battery
Red / fast (0.25s on, 0.25s oft)| Output voltage too low or too high| Wrong LED load connected| Connect right load and perform functional test
 | No load connected or output shorted| Wrong connection| Connect right load and perform functional test
Red/slow (0.25s on, 1.25s oft)| Failed test due to battery| Battery end of life Charger failure| Replace battery and perform duration test Replace driver
Redgreen/fast
Fast flashing: (on-time = 0.25s off-time = 0.25s) Slow flashing: (on-time = 025s, off-time = 1.25s)|  | DALI device identification|
Green / short
on-time = 50ms off-time = 0.95s)|  | Battery detection|

Inrush current

PHILIPS RC136V WIA EL CoreLine Recessed - LED

RC136V WIA

Electrical characteristics
Inrush current Ipeak 4.8 A
 Inrush current Twidth 290
MCB No. of luminaires max.90 (ps)
 16 A type B < 50 pcs

See the technical specification of the LED driver for more information.

  • ****The luminaire shall be installed by a qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.

  • The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.

  • During installation or maintaining the luminaire please use gloves to avoid spots on the cover.
    • To remove dirt and spots use the following:
    • Dust: use micro fiber cloths only.

  • Fingerprints, etc.: use a cleaner for synthetic materials with antistatic properties.

  • Luminaires not suitable for covering with thermally insulating material

  • Luminaire must not be used or stored in corrosive environment where hazardous materials such as Sulphur,Chlorine, Phthalates, etc, are present.

  • Only to be installed outside arm’s reach.

  • If the external flexible cable or cord of this luminaire is damaged, it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard.

ATTENTION *SERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES

According to new ErP requirement
PHILIPS RC136V WIA EL CoreLine Recessed- According
This product contains a light source of energy efficiency class: see table or label.
Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control conductors.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
SR compatibility – For SR-based luminaires only SR-Certified components/sensors are to be used (see also: http://www.lighting.philips.co.uk/oem-emea/products/driving-connected- lighting). The functional compatibility of two (SR-certified) components/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based luminaire, is to be released by the master component/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non-compliance for which Signify cannot take any responsibility.
Zhaga-D4i and SR certified compatibility – For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products_/
https://www.lightingphilips.couk/oem-emeaproductsdriving-connected- lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non- compliance for which Signify  annot take any responsibility.

©202 Signify Holding All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright ow The information presented in this document does not form part of any quotation or contract, is believed to be accurat
reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its us Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property righ
Signify Holding
The Netherlands

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals