Product Description: The Clovis Medium Chandelier is a stylish and elegant lighting fixture that adds a touch of sophistication to any space. It features a metal frame with hooks for hanging chains and comes with a mounting plate, canopy, collar loop, and collar ring. Please note that light bulbs are not included with the product.
Product Usage Instructions
- Carefully remove all parts from the box and place them on a clean, soft surface.
- Remove the collar loop (D) from the chain (F) by removing the quick link (E).
- Install the mounting plate (B) to the junction box and secure it with the provided mounting screws (C).
- Secure the collar loop (D) to the mounting plate (B) using pliers to tighten the locknut.
- Attach the canopy (G) to the collar loop (D) and secure it with the collar ring (H).
- Determine the desired overall length and amount of chain (F) needed. Shorten the chain using chain pliers, keeping the extra chain for future use.
- Attach the chain (F) to the collar loop (D) and fixture loop (I) using quick links (E). Secure the quick links.
- Attach the chains (J) to the hooks on the metal frame (K) and the hooks on the fixture loop (I) as shown in diagram 1 & 2.
- Thread the fixture wire and ground wire through the chain (F). When reaching the collar loop (D), ensure there is no tension on the wires. Cut any excess wires, leaving enough to reach the junction box.
- Separate the two sides of the molded wire and strip insulation on each side by 5/8 inch.
- Loosen the collar ring (H) and carefully let the canopy (G) slip down the chain (F).
- Twist all fixture wires together and slip them through the center hole of the collar loop (D). Untwist the wires and separate them to prepare for connection.
- Wrap the fixture ground wire (bare copper) around the green grounding screw as shown in diagram 3. Tighten it securely. Continue the fixture ground wire and connect it to the supply ground wire (usually green or bare copper) using a wire nut (A). It is important to ensure proper grounding of the fixture.
- Connect the fixture neutral wire (ribbed) to the supply neutral wire (usually white) using a wire nut (A).
- Connect the fixture hot wire (smooth with markings) to the supply hot wire (usually black) using a wire nut (A). Be cautious not to reverse the hot and neutral connections.
- Ensure that all wire connections are tight, then carefully tuck them into the junction box.
- Install the canopy (G) to the collar loop (D) and secure it with the collar ring (H).
- Finally, install light bulbs into the sockets.
ASSEMBLY INSTRUCTIONS
Clovis Medium Chandelier
Item # CHC 5637
NOTICE:
This light fixture should be installed in accordance with all applicable,local
installation codes, and by a person familiar with the construction and
operation of it, as well as the hazards involved. Inspect item and contents
carefully. If any damage or defect is found, do not install.
Retain all packaging material until installation is complete and approved.
TOOLS REQUIRED (NOT INCLUDED)
- Phillips Screwdriver
- Slip Joint Pliers
- Wire Strippers
- Slotted Screwdriver
- Measuring Tape
- Chain Pliers
- Wire Cutters
-
Carefully remove all parts from the box. Place on a clean, soft surface.
-
Remove collar loop (D) from chain (F) by removing quick link (E).
-
Install mounting plate (B) to the junction box and secure with mounting screws (C).
-
Secure collar loop (D) to mounting plate (B) using pliers to tighten locknut.
-
Install canopy (G) to collar loop (D) and secure with collar ring (H).
-
Determine desired overall length, and amount of chain (F) needed. Shorten chain using chain pliers. (Keep extra chain)
-
Attach chain (F) to collar loop (D) and fixture loop (I) using quick links (E). Secure quick links (E).
-
Attach chains (J) to hooks on metal frame (K) and hooks on fixture loop (I). See diagram 1 & 2.
-
Thread fixture wire and ground wire through chain (F).
NOTE: When you reach the collar loop (D), ensure there is no tension on the wires. Cut excess wires, being sure to leave enough to reach the junction box. -
Separate two sides of molded wire, and strip insulation on each 5/8″.
-
Loosen collar ring (H) and let canopy (G) slip down chain (F) carefully.
NOTICE:
This light fixture should be installed in accordance with all applicable, local installation codes, and by a person familiar with the construction and operation of it, as well as the hazards involved. Inspect item and contents carefully. If any damage or defect is found, do not install. Retain all packaging material until installation is complete and approved. -
Twist all fixture wires together. Slip through center hole of collar loop (D).
NOTE: Untwist wires and separate to prepare for connection. -
Wrap fixture ground wire (bare copper) around the green grounding screw (see diagram 3). Tighten. Continue fixture ground wire and connect to supply ground wire (usually green or bare copper) using wire nut (A).
NOTE: It is imperative that the fixture is grounded. -
Connect fixture neutral wire (ribbed) to the supply neutral wire (usually white) using wire nut (A).
-
Connect fixture hot wire (smooth with markings) to the supply hot wire (usually black) using wire nut (A).
CAUTION: Do not reverse the hot and neutral connections. -
Make sure all wire connections are tight, then carefully tuck into the junction box.
-
Install canopy (G) to collar loop (D) and secure with collar ring (H).
-
Install light bulbs into the sockets.
Care Instructions: Clean only with a soft dry cloth or feather duster.
Do Not use abrasive or chemical agents.