KICHLER IS-45295 Alton 1 Light Wall Sconce Instruction Manual
- June 12, 2024
- KICHLER
Table of Contents
IS-45295 Alton 1 Light Wall Sconce
Instruction Manual
IS-45295 Alton 1 Light Wall Sconce
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fuse box before
starting and during the installation.
-
Attach mounting strap to outlet box using the (2) two supplied mounting strap screws. Mounting strap can be adjusted to suit position of fixture.
-
Grounding instructions: (See Illus. A or B).
A) On fixtures where mounting strap is provided with a hole and two raised dimples. Wrap ground wire from outlet box around green ground screw, and thread into hole.
B) On fixtures where a cupped washer is provided. Attach ground wire from outlet box under cupped washer and green ground screw, and thread into mounting strap.
If fixture is provided with ground wire. Connect fixture ground wire to outlet box ground wire with wire connector. After following the above steps. Never connect ground wire to black or white power supply wires. -
Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without tracer| Clear, Brown, Gold or Black with tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
*Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
-
Push fixture to wall, carefully screw in the (4) fixture mounting screws through holes in the sides of the canopy.
NOTE, the fixture can be mounted with the glass in the up or down position. -
Insert recommended bulb (not included).
-
Set glass down over socket.
-
Thread the three (3) thumbscrews into the base as shown. (DO NOT over tighten.)
CAUTION – RISK OF SHOCK –
Disconnect Power at the main circuit breaker panel or main fuse box before
starting and during the installation.
- Attach mounting strap to outlet box using the (2) two supplied mounting strap screws. Mounting strap can be adjusted to suit position of fixture.
- Make wire connections. Reference chart below for correct connections and wire accordingly.
Connect Black or Red Supply Wire to:| Connect White Supply Wire to:
---|---
Black| White
Parallel cord (round & smooth)| Parallel cord (square & ridged)
Clear, Brown, Gold or Black without tracer| Clear, Brown, Gold or Black with tracer
Insulated wire (other than green) with copper conductor| Insulated wire (other than green) with silver conductor
*Note: When parallel wires (SPT I & SPT II) are used. The neutral wire is square shaped or ridged and the other wire will be round in shape or smooth (see illus.)
-
Push fixture to wall, carefully screw in the (4) fixture mounting screws through holes in the sides of the canopy.
NOTE, the fixture can be mounted with the glass in the up or down position. -
Insert recommended bulb (not included).
-
Set glass down over socket.
-
Thread the three (3) thumbscrews into the base as shown. (DO NOT over tighten.)
INSTRUCTIONS
For Assembling and Installing Fixtures in Canada
We’re here to help 866-558-5706
Hrs: M-F 9am to 5pm EST
Date Issued: 06/15/16
IS-45295-US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>