PANADERO ONIX 3V Wood Burning Stove Instruction Manual

June 12, 2024
PANADERO

ONIX 3V Wood Burning Stove
Instruction ManualPANADERO ONIX 3V Wood Burning
Stove Mod.
ONIX 3V/DIAMANT 3V/AMBAR 3V
WOOD BURNING STOVE

ONIX 3V Wood Burning Stove

PANADERO ONIX 3V Wood Burning Stove - Feager

Wood: an ecological fuel
Wood is a renewable source of energy which answers the energy and environmental demands of the 21st century.
Throughout its long life, a tree grows from sunlight, water, mineral salts and CO2. Following the general pattern of nature, it soaks up energy from the sun and supplies us with the oxygen essential for animal life.
The quantity of CO2 given off during the combustion of wood is no greater than that given off by its natural decomposition. This means we have a source of energy that respects the natural cycle of millions of years. Burning wood does not increase the CO2 in the atmosphere, making it an ecological source of energy which plays no part in the greenhouse effect.
In our wood-burning stoves logs are burnt cleanly without leaving any residue. Wood ash is a high quality fertilizer, rich in mineral salts.
In buying a wood-burning stove, you will help the environment, your heating will be very economical and you will be able to enjoy watching the flames, something no other form of heating can offer.

USAGE AND MAINTENANCE INSTRUCTIONS

You have purchased a PANADERO product. Apart from correct maintenance, our woodstoves require installation strictly in accordance with legislation. Our products conform to the EN 13240:2001 and A2:2004 European norm, however it is very important for you the consumer to know how to correctly use your woodstove following the recommendations we set out. For this reason, before installing our product you must read this manual carefully and follow the usage and maintenance instructions.

POSITION OF THE SMOKE PIPE

  1. Place right-angled tube joint in smoke outlet at back of stove.
  2. Place tube in bend, and do the same with the other tubes.
  3. Join it to the rest of the chimney.

IGNITION
The stove you have just bought offers the best performances, a high efficiency and CO and dust extremelly low emissions. In order to get these benefits, the preheated air enters into the combustion chamber through the stove’s top. To favour ignition, you should follow the next tips: – If possible, you should always use small dried pine’s pieces pilled up. Put under this bunch 1 or 2 firelighter and, above ir, the dried firewood cut in half lengthwise. Once the firelighter  fired, close the door and open the air inlet to the maximum. When the fire takes a correct intensity, you can regulate the heat at your convenience with the lower air inlet.

INSTALLATION

  • Under no circumstances should you place horizontally the tubes as it could block the proper smoke evacuation and the stove’s correct function.
  • All local regulations, including those referring to National and European standards need to be complied with when installing the appliance.
  • The installation of the smoke outlet must be as vertical as possible, avoiding the use of joints, angles and deviations. If the installation is connected to a masonry chimney pipe we recommend the tubes reach the exterior exit. If the  smoke outlet is via tubing only, at least three meters of vertical tubing are recommended.
  • IMPORTANT: The installation and regular cleaning of this stove must be carried out by a qualified professional. The ventilation opening must never be obstructed.
  • IMPORTANT: The woodstove must be installed in a well ventilated place. It is advisable to have at least one window in the same room as the stove which can be opened.
  • The tube connections should be sealed with a refractory putty to prevent soot from falling through the joints.
  • Do not position the stove near combustible walls. The stove should be installed on a non-combustible floor surface, if not a metal plate covering the bottom surface area of the stove must be placed underneath it and extend further  than 15 cm at the sides and 30 cm at the front.
  • Whilst the stove is in use remove any material nearby which could be damaged by the heat: furniture, curtains, paper, clothes, etc. The minimum safety distance from adjacent combustible materials is as shown on the last page of this manual.
  • The ease of access for the cleaning of the product, smoke outlet and chimney must be considered. If you intend to install your stove near an inflammable wall, we advise you to leave a minimum distance to facilitate cleaning.
  • The stove should be installed on flooring with adequate support. If your current floor does not comply with this criterion, it should be adapted with appropriate measures (for example, a weight distribution plate).

FUEL

  • Use only dry wood with a maximum moisture content of 20%. Wood with a moisture content higher than 50 or 60% does not heat and combusts very badly, and creates a lot of tar, releases excessive amounts of vapour and deposits  excess sediments onto the stove, glass and smoke outlet.
  • The fire should be lit using special fire lighters, or paper and small pieces of wood. Never try to light the fire using alcohol or similar products.
  • Do not burn domestic rubbish, plastic materials or greasy products that can pollute the environment and lead to risks of fire due to obstruction of the pipes.
  • In TRIVISION stoves, in order for the side windows to remain clean, the firewood to be used must be very dry, with a humidity percentage of less than 111222%%%…

FUNCTION

  • It is normal for smoke to appear during the first few uses of the stove, as certain components of the heat-resistant paint burn whilst the pigment of the actual stove is fixed. Therefore the room should be aired until the smoke disappears.
  • The woodstove is not designed to function with the door open under any circumstances.
  • The stove is intended to function intermittently with intervals for recharging the fuel.
  • For the lighting process of the stove it is recommended you use paper, fire lighters or small sticks of wood. Once the fire starts to burn, add to it two logs of wood each weighing 1 to 1.3 kg as a first initial charge. In this lighting  process the air inlets of the stove must be kept completely open. If necessary the drawer for removing ashes can also be opened to begin with. Once the fire is more intense, close the drawer completely (if open) and regulate the intensity of the fire by closing and opening the air inlets.
  • In order to achieve the stated nominal heat output of this stove a total quantity of 1.38 kg. of wood must be placed inside at intervals of 45min. The logs should be positioned horizontally and separate from one another, to assure a  correct combustion. In any instance a charge of fuel must not be added to the stove until the previous charge has been burnt, leaving only a basic fire bed which is enough to light the next charge but no stronger.
  • After the first initial lighting, the brass pieces of the stove may become a coppery colour.
  • It is normal for the seal of the glass door panel to melt with use. Even though the stove can function without this seal, it is recommended that you replace it seasonally.
  • The lower drawer can be removed in order to clear out ash. Empty it regularly without waiting for it to fill up too much, to avoid the grill becoming damaged. Take care with the ash which may still be hot up to 24 hours after the stove has been used.
  • Do not open the door abruptly in order to avoid smoke being released, and never open it without opening the air draught beforehand. Open the door only in order to put in the appropriate fuel.
  • The glass, brass pieces and stove in general may reach very high temperatures. Do not expose yourself to risks of burns. When handling metal pieces, use the glove provided with the stove.
  • Keep children away from the stove.
  • If you have trouble lighting the stove (due to cold weather, etc.) it can be lit with folded or scrunched up paper which is easier to light.
  • In case of the stove becoming too hot, close the air draughts to reduce the intensity of the fire.
  • In case of malfunction, contact us the manufacturers.

MAINTENANCE

  • It is advisable to clean the glass door panel periodically to avoid blackening by soot deposits. Professional cleaning products are available for this. Never use water.
    Never clean the stove while it is in use.

  • It is also important to clean the smoke outlet tubing periodically and check there are no blockages before relighting fuel after a long period of non-use. At the start of each season a professional should carry out a revision of the installation.

  • In the event of a fire in the smoke outlet, close all air draughts if possible and contact the authorities immediately.

  • Any replacement part which you may need must be recommended by us.

GUARANTEE
This is a high quality stove, manufactured with great care. Even so, if any defect is found please first contact your distributor. If they are unable to solve the problem they will contact us and send us the stove if necessary. Our company will replace any faulty parts free of charge up to five years from the date of purchase. We will not charge for  repair work, however any transport costs must be paid by the client.
Since this apparatus has been tested by a homologated  laboratory the following parts are NOT covered by warranty:

  • Glass
  • Door handle, air-inlet knobs, etc.
  • Internal grate and cast iron door
  • Vermiculite

In the interior of the packaging, you will find a quality control slip. We request that you send this to your distributor in case of any claim.

MEASUREMENTS AND CHARACTERISTICS

– Height…………………………………………… 810 mm
– Width……………………………………………563 mm
– Depth……………………………………………..396 mm
– Weight……………………………………………95 Kg
– Firewood entrance ………………………….485 x 361 mm
– Smoke outlet ………………………………….150-153 mm
– Iron sheet body of 4 + 3 mm.
– Cast iron grill
– Paint, resistant up to 800 °C
– Vitro-ceramic glass, 750 °C
– Firewood up to 50 cm long
– Nominal heat output ……………………………7.1kW
– Energy efficiency …………………………………77.0 %
– CO emission ………………………………………0.10 %
– Minimum flue draught for
nominal heat output ……………………………….11.8 Pa
– Flue gas mass flow ……………………………..6.2 g/s
– Flue gas temperature …………………………..271 °C
– Distance to adjacent
combustible materials …………………………50 cm
– Heating volume (approx..) ……….220 m³

DIN EN 13240: 2001 & A2: 2004 & AC: 2007| P.I. CAMPOLLANO
AVENIDA 5ª, 13-15
02007 ALBACETE -SPAIN
---|---

“ONIX/AMBAR/DIAMANT” WOODSTOVE……………… 19
FREESTANDING ROOMHEATER FIRED BY SOLID FUEL
CERTIFICATE Nº ……………………….TD4781; TD 4781P
DECLARATION OF PERFORMANCE…………..18695/18696/18697
NOTIFIED BODY…………………………………………1677
Thermal output…………………………………………… 7.1 kW
Energy efficiency ………………………………………..77.0 %
Emission of CO in combustion products … 0.10 %
Flue gas temperature ……………………………………. 271 °C
Distance to adjacent combustible materials 50 cm
Dust concentration at 13% O2 ……. 30 mg/Nm³
Fuel types ………….. Firewood and briquetted wood

PANADERO ONIX 3V Wood Burning Stove - Feager1

HOW TO OPERATE YOUR WOOD STOVE EFFICIENTLY

https://panadero.com/how-to-operate- your-wood-stove- efficiently/ P.I. CAMPOLLANO
AVEN I DA 5ª, 13 -15
02007 ALBACETE – SPAIN
Telf.: (+34) 967 59 24 00
Fax: (+34) 967 59 24 10
panadero@panadero.com  

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals