Product Information
- Product Name: simalube
- Manufacturer: simatec ag
- Website: www.simalube.com
- Available Sizes: 30ml, 60ml, 125ml, 250ml
- Power Generation: Hydrogen gas producing dry cell
- Certifications: – Directive 2014/34/EU of the European
- Parliament and the Council
- EN 60079-0:2018
- EN 60079-11:2012
- EN 50303:2000
- Notified Body : DEKRA Certification B.V.
- Certificate No. KEMA 09ATEX0098X IECEx DEK 20.0032X
Product Usage Instructions
1. Read the user manual and technical information before using the simalube.
2. Determine the appropriate simalube size and time setting using the
Calculation Pro feature of the Simatec app.
3. Use only original accessories with the simalube.
4. If you have technically demanding or unusual applications, contact the
technical department or your local distributor for assistance.
5. Ensure that the lubricator is not started without opening the outlet or in
case of blocked grease lines within the installation.
6. In such cases, the pressure in the lubricator can build up to
approximately 5 bar. If the overpressure reaches approximately 6 bar, the
lubricator may break at the defined breaking point between the housing and
bottom, releasing the pressure behind the piston and causing oil or grease to
come out at the breaking point.
7. For further information on operation and disposal, refer to the electronic
user manual on the Symantec website
(www.simatec.com/manual/simalube) or
scan the QR code provided.
8. Follow all safety instructions mentioned in the user manual and technical
information.
9. For any additional information or inquiries, contact Symantec ag at their
address: Stadthof 2, CH-3380 Wangen a. Aare.
Quick Installation Guide
simatic app world of maintenance
With the «simatec world of maintenance» app, the lubricators can be easily configured and then monitored without having to be directly at the lubrication point.
Calculate your simalube size and time setting with Calculation Pro, from now on part of our new simatec app.
Accessories
Note: Use only original accessories. If you have technically demanding or unusual applications, please contact our technical department or your local distributor.
- Typ 30, 60, 125 ml:
- II 1 G Ex ia IIC T6 Ga
- II 1 D Ex ia IIIC T200 80°C Da
- I M1 Ex ia I Ma
- Typ 250 ml:
- II 1 G Ex ia IIC T4 Ga
- II 1 D Ex ia IIIC T200 135°C Da
- I M1 Ex ia I Ma
TÜV SÜD Product Service GmbH, Germany, TPS 21 ATEX Q 029499 0026
TÜV SÜD Product Service GmbH, Germany, DE/TPS/QAR20.0016/00
Power generation: Hydrogen gas producing dry cell
Operating temperature: –20 °C to +55 °C (–4 °F to +131 °F) ambient
temperature
Security note
If the lubricator is started without opening the outlet or in case of blocked grease lines within the installation, the pressure in the lubricator can build up approx. 5 bar. At an overpressure of approx. 6 bar the lubricator breaks at the defined breaking point between housing and bottom. The pressure behind the piston releases and oil or grease can come out at the breaking point.
Warning : For applications in an environment with an explosive atmosphere, there is a risk of electrostatic discharges or of propagating brush discharges on the surface of the lubricator. Suitable precautionary measures must be taken to minimise the risk. To avoid electrostatic charging during cleaning, only clean the lubricator with a damp cloth. Do not expose the lubricator to any air flow that may result in electrostatic charging of the lubricator.
The correct functioning of the lubricator can only be assured if recommended lubricants and original simalube accessories are used, and if the installation, operating and maintenance instructions are closely followed. The manufacturer cannot accept any responsibility for damages as a result of ignoring the instructions mentioned above. Important: Before putting the simalube into operation, fill extensions and the lubrication lines with the appropriate simalube greases (cartouches SL01…SL26) using a grease gun. Use only original accessories.
Further information
For further information on operation and disposal, refer to the electronic user manual on www.simatec.com/manual/simalube or directly via the QR-Code.
EU Declaration of Conformity simatec ag
Stadthof 2 in CH-3380 Wangen a. Aare declares that the single-point
lubricators
simalube & simalube multipoint
are designed and manufactured in accordance with Directive 2014/34/EU of the
European Parliament and the Council on the harmonization of the laws of the
Member States relating to equipment and protective systems intended for use in
potentially explosive atmospheres. The following standards have been applied:
- EN 60079-0:2018
- EN 60079-11:2012
- EN 50303:2000
- Notified Body : DEKRA Certification B.V.
- NL-6825 MJ Arnhem
- Identification number : 0344
- Certificate No.
- KEMA 09ATEX0098X
- IECEx DEK 20.0032X
- Wangen a. Aare, 01.06.2022
- Mischa Wyssmann, Managing Director/CEO
Installation of the oil lubricator: Lubricators with non-return valve plugs can be installed in any position required.
Important : The non-return valve plug can only be used once. If the lubricator is refilled the non-return valve plug must be replaced by a new one.